  1. W

    price of a worcester combi install

    went to a customers today where they had a new worcester combi fitted.the original boiler was an open vented system.,the installer removed old boilerfrom downstairs,bricked up/made good,relocated new boiler to airing cupboard,upgraded gas supply,3x flue extensions roof terminal and pitched roof...
  2. W

    potterton performa 28i

    i must be having brain drain on this one,customer getting intermittent hot water,attended and checked thermistors,limit stat,burner pressure,all correct values,they had a new secondary plate heat exchanger and divertor assembly fitted three months ago(not by me).i have checked all connections...
  3. W

    worcester 30si

    went to this boiler failing to ignite and after carrying out tests discovered no power to gas valve,replaced pcb and got no fan,power to fan so fitted another fan (old one on van)so fan working and power to gas valve,still faulting out so replaced gas valve,yipee up and running.anyone else had...
  4. W

    gas safe registered engineers.

    just browsing and noticed someone asking for advice,looking at their gs number i am surprised and shocked at how many there are,i wonder what the newest registration number is?
  5. W

    new gas fire installation

    got called out tonight to a suspected leak on a gas fire installed yesterday(not mine)leak found on new pipework,sorted out leak on pipework and relit fire,i noticed that there was sooting on the coals and the back of the coal panel,did fga on it and the reading was 1574ppm,fga went ape,anyway i...
  6. W

    bailey drain rods

    wheres the best place to buy a set of these and which set are the best,all input appreciated:cool:
  7. W

    glowworm 38cxi

    called out tonight to have a look at above,f14 fault showing,this only happens on h/w demand,does not need resetting,it will fire back up once it has cooled sufficiently,i am thinking plate hx,they have to keep repressurising the system as there is a leek on the circs,any input appreciated:cool:
  8. W

    wheres the work gone?

    i don,t know if anyone else is experiencing this,but i have never known it go so quite,two weeks now and am just limping on,whats your views?
  9. W

    c&m brittony combi 100se

    with reference to the above,customer informs me boiler working fine in central heating and hot water mode.the problem she has is the fan is constantly running,pump overun stops after three minutes but the fan comes on as soon as the boiler is switched on and does not stop until power is switched...
  10. W

    water softeners

    looking for recommendations on these,i am contemplating installing one in my own home and would appreciate all opinions/views. regards simon
  11. W

    ideal mini he

    hi all i am going to the above tomorrow and would just like some suggestions,apparently the boiler is firing up intermittently,i am informed that when heating/hw called for it will work and other times will just lock out,my initial thought was the venturi(last service unknown)any thoughts...