Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. N

    Best LL gas cert app?

    Im giving this one a go at the moment and it seems pretty decent, thanks
  2. N

    Best LL gas cert app?

    Thanks for the suggestion mate, appreciated
  3. N

    Best LL gas cert app?

    Found this thread mate. Last updated 2023 but im going to have a look through some of the suggestions. https://www.plumberstalk.net/threads/gas-engineer-software.130734/
  4. N

    Best LL gas cert app?

    Hello all, i was wondering if anyone could share their thoughts on what they would deem to be the best LL gas cert app on the market, currently doing paper ones like a dinosaur and would be nice to get some recommendations from other guys. I did try searching this to see if there was already a...
  5. N

    Air Source Heat Pumps

    I have been thinking of going on this course but my only reservation with it is reaching out to the right clientele, has anyone made this transition and started fitting these units? And if so, was it worth doing the course for the amount of work gained afterward?
  6. N

    What valve is the flow

    Hi mate, a mountain being made out of a molehill by a few here to be honest, get some bi directional valves and put them on, Danfoss ones are usually bi directional and it is far from the end of the world if they are the wrong way around, just out them on and if you get it the right way happy days.
  7. N

    Fitting ABS pipe

    Anyone worked with this plastic pressurised pipe much? This week was my first and i thought after my years of experience that these stressful days were mostly behind me...alas they are not. Ordered up the stuff in preparation for the job, informed the entire building that the water would be off...
  8. N

    Commissioning Vokera Easi Heat

    Good morning all, just a quick one here and i was wondering if someone could give a little advice on their own experience. I don't usually do a lot of installs or a tremendous amount of gas work but obviously when I do undertake these things then I try my best to keep within the appropriate...
  9. N

    Zero Governors and Gas Analysis

    Morning all, I am just about to begin doing more installs of combi boilers, I am gas safe but just never really done a lot of installs due to being busy with general plumbing and bathrooms. One question that i have is, when checking working pressure on a boiler with a zero governor what sort...
  10. N

    Motorised valve on hot water

    So, I went to this job yesterday to change over a faulty motorised valve on the hot water side of an unvented system. I drained the system, wired the new one up and fitted the new valve, this system is fed from a communal boiler in the building which might be part of the reason for the issue I...
  11. N

    Thermal Store cylinder

    So...got called to this earlier on, the install looks a bitnof a mess but looking past that the system seems like quite a simple setup though i am failing to find a schematic for this particular type of thermal store where we have 4 immersers which all on would be producing 12kw and an open...
  12. N

    Water cylinder re heat time

    Hello all, i am doing work for a customer who has asked me what the reheat time of a 250 litre cylinder is. To be honest after all the years of doing plumbing this is a question that i have never been asked before because usually if you need a hot water cylinder then it is what it is, you just...
  13. N

    Hunter Genova Pipework

    I came across this for the first time yesterday, i have seen something similiar in the past when i was an apprentice but that was a long time ago. Just thought that i would put this up so as to help anyone out there that may come across it. Its plastic pipe that takes cold main, in this...
  14. N

    silt in logic condensate

    Was at a job where the guy reported that his boiler was making a loud vibrating noise when using the hot water, took a look at it and the boiler display was saying Pump over run and Fan post purge Took the condensate trap out and found both the trap and the little rubber feed on top of the...