  1. S

    hot water not staying hot in an unvented system

    hello we have an unvented system. we have an issue where the hot water is hot for 10 seconds and then luke warm, turn off taps / wait and turn back and it repeats itself. had boiler checked and told it was the expansion vessel. Had the expansion vessel drained and recharged. plumber told me...
  2. S

    at annual service told boiler was dirty - is this a way to be ripped off

    hello i have scottish power boiler cover .. a couple of times recently boiler shut down on its own (keston) had annual boiler service and engineer told wife the boiler is dirty .. does this mean there is sludge which of course isnt covered so it this an excuse for the plumber to try and make...
  3. S

    boiler that accepts horizontal flue

    hello have a keston boiler.. touch wood .. working ok .. but time soon to replace .. we originally got a keston because there is a horizontal flue over about 5 meters .. which other brands of boilers would be able to be slotted in to replace the keston when needed ? thanks
  4. S

    using a pump with a combi boiler

    hello, was chatting to a friend, he has a good size 5 bedroom house .. current system is a combi boiler and he is looking to upgrade bathrooms and water supply as currently using a tap stop the hot water to the shower i was surprised when he mentioned to me the the plumber is recommending...
  5. S

    advice re keeping combi boiler and adding a booster pump

    hello, was chatting to a friend, he has a good size 5 bedroom house .. current system is a combi boiler and he is looking to upgrade bathrooms and water supply as currently using a tap stop the hot water to the shower i was surprised when he mentioned to me the the plumber is recommending...
  6. S

    bay window radiator question

    hello i have a room with a bay window and currently has a single panel curved radiator .. the room is too cold in winter so looking for a replacement the curved double radiators i have seen seen are very pricey.. i was quoted over £500 to curve a double radiator as the bay is nearly...
  7. S

    looking for an engineer for a cp12 se london

    hello i am in need of an engineer to do a landlord cp12 certificate .. keston boiler (ahhhhh) with a horizontal flue... , hatch for access but need engineer to be friendly and practical about it greenwich se london