Search results
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Search results

  1. P

    Shower installation help

    i have a client looking to have a pumped shower of some sort, open to options that will work , basically they have 25 gallons cold water storage cistern and 114litres 900 x 450 hot water water cylinder . its an older property with a weird lay out which would mean the shower head is pretty much...
  2. P

    Pricing to replace a vented cylinder with an unvented cylinder (megaflo)

    Hello , ive recently gone out on my own, i have been working in the industry 15years now /g3 qualified and i would just like to get some advice from the knowledgable people on this forum! i have done a lot of installing but haven't really got involved with the design as somebody else has done...
  3. P

    bath screens and shower screens

    Hello people! just looking to do a bit of product research really and see what people are using and finding the best. What Manufacture screen do you usually use? What Thickness glass would you usually go for?
  4. P

    Shower pump options please

    Hi im looking for some advice . The cylinder is sited about 15metres away from shower which is currently gravity fed there is a 25 gallon (113 litres) cold water storage tank in the loft and a 1800 x 500 cylinder (276 litre) in a bungalow . the clients want a more powerful shower but are...
  5. P

    Will the shower room need an extractor fan?

    hi , Ive only ever fitted bathrooms and put in what somebody else has already sorted out basically, I'm looking to further my knowledge now and eventually go out on my own and ventilation is something i haven't really got involved in tbh. i have a small shower room that I'm looking at its 1.5m...
  6. P

    What bathroom furniture do you recommend?

    hi everyone , I usually use calypso for bathrooms as I've never had a problem with there products but i have a customer thats on a tight budget , was just wondering what manufactures are you using that you have tried and tested ? who would you use for budget /mid range/high end ?
  7. P

    What’s the max length on a horizontal soil pipe with new connection going into a drain

    As above really what’s the max length a soil stack can be run horizontally, it will be feeding a toilet and a basin . Getting confused by the tables below as table 2 says 15m and table 1 says 6m ? Can anyone help?
  8. P

    How do I know if cylinder can cope with shower ?

    Looking to fit an Aqualisa visage shower they say a 50 gallon cold water storage cylinder is minimum but don’t give a figure for the hot water . How would I work out if the hot water cylinder size would be adequate ?
  9. P

    Worcester combi boiler cutting out on hot

    Replaced a bath tap with shower attachment and Fitted a Aqualisa Midas thermostatic bath /shower mixer . During the shower sometimes the water goes cold for a few seconds and goes warm again and customer said the boiler is cutting out then coming back on when it does this . Almost like it’s...
  10. P

    Water splutters and splashes out . Why could remedy this ?

    i live in a flat on the top of 3 levels with a bathroom and an en-suite . It is high water pressure here and we have a 210litre unvented hot water cylinder . The pipework goes up into the roof space and goes to each supply. We have had these problems since moving in but basically the water...
  11. P

    Sabre 29he boiler problems

    for some reason my other post has been deleted :s Sabre 29he Combi , originally customer said it was clicking on and off on hot water so thought it was heat plate blocked causing it to reach temp to quick and cut out so I have changed heatplate and changed divertor at the same time but not...
  12. P

    Vokera sabre 29he got water fault

    hello! Has anyone worked on these Vokera sabre 29he combi boilers? I have one that when you run the hot tap it clicks loudly at pcb area and goes cold then hot . Initial thoughts are a blocked heatplate but it looks like I have to take everything apart just to take it off and check it! Has...
  13. P

    Vokera sabre he29 hot water fault

    hello! Tried to post this in the gas safe part but it wouldn’t let me for some reason. I’m gas safe registered Has anyone worked on these Vokera sabre 29he combi boilers? I have one that when you run the hot tap it clicks loudly at pcb area and goes cold then hot . Initial thoughts are a...