Search results

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

Search results

  1. R

    Hot water coming on combi sometimes other times not

    Hi guys thankfully not been needing to com on for a while but could do with a pointer. 2 weeks ago I noticed boiler didn’t fire for hot water in kitchen which is next to boiler and cold main in, it came on after a few seconds longer than norm I thought just a blip, but this weekend and since...
  2. R

    How long for boiler to cool to check pressure

    Hi guys really quick question I’m assuming if I’ve not had my heating on for 24 hrs n the boiler pressure is sitting at 1.4 bar which is what it was topped up to after service 3 weeks ago that’s its pressure at cold as in its resting pressure, suppose what I’m saying is after 24 hrs of no...
  3. R

    New rads fitted 4 weeks later one needing bled

    morning guys just looking for some advice I think the answer is hopefully straight forward however just double checking got 3 new rads fitted a just over a month ago however one had a small leak which got sorted a 3-4 weeks ago last night I noticed one of upstairs rads had a slight cold patch...
  4. R

    How do I know if expansion vessel faulty

    Evening everyone so I’m just wanting to as a quick question please, how quickly would the pressure rise to over 3 if my expansion vessel is faulty been using the boiler but only a hour at night and at morning just now as it’s heating up the house with being mild ish outside normally over the...
  5. R

    Very slight pressure loss

    Hey guys I have a quick question I hope you all can help with I have Ariston class he evo 30 boiler it’s just over a year old we got 3 new tads fitted a few weeks ago as old ones were rusting at the top valves anyway we had a small leak in the pipe going into the new one which my heating...
  6. R

    Should my boiler ask for heat constantly when on

    Hi everyone sorry to bother on a Sunday, I have a Ariston clas HE 30 Combi just over a year old, been working fine and kind of still is I’m just on to ask a general question basically I got 3 new rads fitted Friday 3 old ones about 20 years old and up one from a single to double with TVRs before...
  7. R

    Ariston class he 1P1 error

    Sorry deleted thread
  8. R

    Boiler briefly calling for heat after shutting cold water tap

    hi guys any help or advice would be good, I have a Ariston Clas eco he 30 combi boiler it’s only 9 moths installed but just noticed that it occasionally calls for heat if just after the cold water tap is closed it’s litteralky a second the icon for head comes on n then off I’m assuming that’s...
  9. R

    Boiler not listed on BG boiler cover

    Guys I registered for boiler cover with BG guy came out today but it’s not on System for parts I got it installed 7 months ago it’s a Ariston Clas HE evo 30 but the guy did say he thinks it’s due to it being a new model boiler and parts not released yet they can get some but some for special...
  10. R

    Anyone know if BG cover Ariston Clas evo he 30 combi

    Hi everyone just a quick question the boileris only 7 months old but the Mrs wants to put it on a plan basically for piece of mind I know there are some boilers BG won’t cover as the last one we had they didn’t but it was a real bad un!! They are coming out for first inspect in a couple of weeks...
  11. R

    Boiler going on randomly salus RF300 stat

    Guys first time in here I got anew boiler fitted about 7 months ago with aforementioned stat boiler all working well but about a month ago I got back from hols n it started to fire up itself no flame indicated on remote but receiver lite green as if getting a signal I reset the boiler & stat...
Back