Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

boiler

  1. P

    Lukewarm water problem with Veissmann v 50 gas boiler

    Hi all, thanks for adding me. My Veissmann v50 combi gas boiler has recently started to supply only lukewarm water to the bathroom above it. This is about 3 metres away, so quite a short pipe run. It supplies hot water fine to the kitchen taps, which are about 1 metre away. It also supplies very...
  2. D

    Password to check the programming of a Grant Spira Wood Pellet Boiler?

    What is it? It apparently is obvious when one knows it. The last numbers of the serial number for example. Anyway, it hasn't been changed from the Grant factory set password,,, though it is numbers.
  3. M

    Banging boiler with embers?

    Hi, I turned my central heating on for the first time today this year and it started to bang and the flame inside looked a bit erratic. Upon looking in the pilot light viewer it looks like there is debris/embers burning resting on the bottom. I turned everything off and switched it back on to...
  4. N

    Vailant thermostat vrt350 not pairing with ecotec pro 28 boiler

    Hi everyone, I’m writing on behalf of my elderly neighbour and hoping this is a problem someone on this forum has experience of and remedied. The boiler was not responding to the wireless thermostat. The various settings on the thermostat seemed fine and 3 heating times and temperatures were...
  5. siricosm

    Boiler replacement in Norwich

    I need someone to replace my boiler, I am thinking to get an Intergas HRE 24 SB. Our current boiler (and old Ideal) is in the kitchen, and we would like to relocate it to the laundry room or loft, so a new gas line needs to be run. I would prefer someone local in Norwich that can also do the...
  6. H

    Zone Problems with Boiler

    I have an older gas boiler HW heating system with a taco circulator pump for each zone that worked fine last season. When turning it on for the 1st time this season I found a problem with the boiler not running on one of the zones. If I turn on the heat to zone 1 I hear the system...
  7. J

    System or Heat Only Boiler

    A (if) CH system has a very high head loss due to improperly sized pipework and long runs and possibly partially blocked pipes and requires a UPS2 pump running at its 8M head to feed 21 rads with a theoretical output of 25kw at a 20C dT. A fairly old Vaillant 438 boiler is being replaced, the...
  8. D

    Ideal logic combi boiler with mechanical timer swap with electrical

    Hi all, i moved recently in new home and realised that there is no room external thermostat wired to the Ideal Combi boiler. There is only mechanical timer on it. I saw some videos on Internet that mechanical timer can be replaced with electrical one but i am not sure if it is compatible with...
  9. P

    Combi boiler: my hot water has started running lukewarm.

    I have a Combi boiler and, a few minutes ago I turned on the hot tap in the kitchen and the water was far from hot. In fact, it was decidedly lukewarm. I checked the boiler and the tap icon was lit up, showing it was delivering hot water to the taps and I could hear the boiler running and the...
  10. J

    Boiler or pipes STILL banging when CH is cooling down,any ideas?

    I posted in summer as HW system banged when cooing down it is now even worse once CH is cooing down but it's common between both systems any ideas folks, desperate now. Potterton combi boiler 10 yr old inherited 4 yr ago when I bought house, no issues until earlier this yr.
  11. S

    Can I override boiler ,thermostat broken

    I have a ideal logic 30 boiler ,the thermostat receiver looks to have died ( no lights on wired receiver ) I believe this need# replacing but in the mean time does anyone know if I can override the thermostat if heating is required please? the handheld thermostat is working it’s the boiler...
  12. R

    Seized baffles in worcester boiler

    Seized baffles - can anyone give advice how to free them ? Worcester Camry boiler
  13. B

    New boiler overheated

    I must be cursed The new boiler that was fitted yesterday had a problem on commissioning, when the central heating was turned on the boiler fired but the pipework was only getting hot up to a certain point, it took the plumber a couple of hours to figure out what was happening, the problem was...
  14. Z

    Baxi duo tec combi 24 HE A Boiler de-aeration

    Hi everyone, I wanted to ask is there a function to remove air from a Baxi duo tec combi 24 HE A. If there is can some one kindly tell me the procedure. Looking online i found on newer baxi boilers that you turn the heating knob all the way back (12-oclock) anti-clockwise and then 2 quarter...
  15. J

    Boiler making loud noises recently

    Hi All, my boiler starts to make some loud noises recently when running (a sound file is attached). A gas engineer will come around sometime next week. In the meantime, appreciate any advices on what could be the cause. Thanks very much!
  16. RenzoPan

    Boiler and Megalow mistery

    Boiler and Megalow mistery Hi, Just moved into a house from a flat and I have a couple of queries. We have a Worcester gas fired boiler - Greenstar Ri (in the kitchen on ground floor) and a megaflow (on the first floor) plus a small red tank that I do not know what it does. Heating is set to...
  17. N

    Intergas Boiler pressure dropping

    Intergas Boiler (only 2 years old and serviced each year) pressure dropping to 0b after just 1hr of running - can anyone help? No leaks anywhere
  18. R

    Grant oil boiler problem

    Any advice welcome as plumber stumped Had 36-46 grant vortex utility boiler 7 years no problem recently oil tank move and tigerloop install (tank about 1m lower). 10 days later and boiler either doesn't fire or fires stops, fires runs splutters stops. Most it runs now is 10 mins, but that's...
  19. B

    Boiler in tall larder unit ?

    Is it OK to have my boiler in a full height 600mm larder unit 2000mm high,instead of a normal wall boiler unit ? So i can store stuff underneath ,but maintaining the minimim gap around the boiler for servicing etc See pic of my boiler
  20. Z

    Oil fired boiler on lockout

    My oil fired boiler won’t fire up it is in lockout After a power cut my oil feeder is showing out of fuel- it isn’t. And now my boiler is in lockout and won’t fire. It was working fine before the power cut. Checked & no air in the system Plumber thinks I need a new feeder but I’m unsure...