flue

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

flue

  1. F

    Flue advice on excess water coming out

    I've recently had a Baxi heat only boiler fitted and just noticed there is excess water coming out of the flue. I obviously will ring the company to get them back. I just wanted to get a bit of information beforehand. Can these flues be repositioned? On mine you can see the water pools forward...
  2. P

    Could the BAXI commercial boiler parts/flue melt ?

    Boiler is SIRIUS THREE FS 70 Potterton commercial. Situation: We are small building contractors and my labourers managed to damage the radiator pipes during the strip out. Not the end of the world as damages happens. I am responsible builder and paying my bills and to repair the damages if...
  3. M

    Viessmann external flue run conundrum

    Hi all. Hope you have all been keeping well. A while back I decided I only wanted to fit one brand of boiler and decided on Viessmann due to space for servicing and changing parts if ever needing to. I am finding my decision rather hard due to the different clearances on flue runs and cupboards...
  4. E

    Can this Boiler Flue be reduced in size?

    Hello All, I was hoping you could help with a potential boiler build query for my father. He has recently had a new boiler installed via British Gas (valiant brand). The external boiler flue seems excessively tall, proving to be somewhat of an eye sore (please see pictures attached). I know it...
  5. B

    Protherm flue extender

    Looking for a flue extender for a Protherm 60-80CI boiler. House is having external wall insulation and needs flue extending to avoid a new boiler just now. The boiler is GC no 41-047-66 and the flue extender had part no 230484. Anyone got one lying on their shelves? Thanks Paul 07761 103482
  6. C

    Worcester Bosch Heatslave 26/32 (Oil boiler 2007) Flue perished

    Oily smell from boiler recently before failed. Great plumber sorted though when opened external baffle at front of sealed flue the internal spring like tube lining outer insulation had all perished. Barn conversion with thick walls (763mm). Worcester Bosch say Flue Kits are obsolete and...
  7. samwardill

    Flue problem . How best to get it looked at ?

    I’m getting water in my boiler which I think is coming from the flue (pictured). Is it likely that the issue is with the flue itself or the roof junction? I guess if it is the roof then I’m better asking a roofer rather than a heating engineer - right?
  8. S

    Flue position - will this be a problem?

    We are considering buying a house which currently has a 20 year old Ideal Icos boiler, so we're factoring in replacing the boiler soon. Current boiler is on an external kitchen wall with the flue going straight out. However, it's positioned in between a door and the kitchen window, quite close...
  9. G

    What type of flue liner do I need?

    Hi Guys, My chimney failed the test so I need to install a flue liner for my Gazco Stockton gas fire. It was over a year ago when the engineer condemned the chimney and I remember him also saying something about it needing some sort of box fitted into the fire recess but I can't remember the...
  10. Stout0607

    Flue integrity failed I'd or at risk

    flue integrity test failed on a room sealed boiler however not effecting combustion and not leaking into room, would it still be I'd or can it be at risk.
  11. O

    Remove Old Unused Flue Pipe?

    Hi, long story short, our boiler has been replaced with a combi and the loft and airing cupboard are now devoid of tanks and pipework, except.... ... this old flue pipe, which was once connected to the original boiler when our home was built in the mid-80s. It runs from a vent on the roofline...
  12. J

    Wanted vaillant ecomax 18e flue collector cardboard template

    Hi can anyone help. Flue collector on vaillant ecomax 18e needs refitting but no longer have the cardboard template included in the kit. Does anyone have one? Full kit is 076560.
  13. dilligaf

    Glow Worm Micron 30FF Flue?

    The flue for a glow worm micron 30ff is apparently obsolete but there must be other flues that would fit it surely, it's just a standard 100mm horizontal flue right? I mean when a bg gas engineer tells you that you'll have to change the whole boiler as well because you can apparently no longer...
  14. S

    Mixing Vertical and Horizontal Combi Flue

    My installation has been classed as Dangerous 'Do not use' by my boiler manufacturer. I have an Ideal Logic 30kw Combi boiler mounted as high as can be on the kitchen wall. Flue exits out through the wall via an elbow but emerges above a flat roof. Unfortunately it's somewhat less than the...
  15. M

    Sealant for external flue run.

    Hi all. Got to run a Vailliant flue externally and been told by vailliant I need a heat resistant flexible silicone. Can anyone recommend which silicone to go for? Cheers
  16. E

    Back boiler venting and flue requirements

    Hi all, Apologies if this has been covered elsewhere but I can't find an answer to my questions. I have a back boiler and gas fire which h has been serviced regularly over the years by different engineers with no issues. Last time , the guy wanted to condem it due to not being compliant with...
  17. G

    Thoughts on this flue

    Installed 2 days ago, Worcester 4000. Haven’t seen anything like this before, any thoughts. Personally I would have gone horizontal with an offset bend in the roof space ( to get minimum distance from boundary) and terminated at the gable end.
  18. H

    Can the flue be bent upwards to meet the distance rule from a window?

    I had a combi boiler put in my rental property about 10 years ago by a contractor arranged by the letting agency and I assume qualified. Gas safety checks have never highlighted a problem. This year they have turned off the boiler because the bottom of the flue pipe is 200mm from the opening...
  19. M

    Vertical flue/ roofing query??

    Hi guys. How many of you use a roofer to help with vertical flue installations, or do you rather do it yourself?? I’m not one for heights so would rather not if possible.
  20. T

    Kitchen extractor ducting to boiler to boiler flue.

    Morning, Im in a top floor tenement flat with access to the attic space. I have a combi boiler with flue that emits vertically up through the roof. My kitchen is situated internally with no easy access to an external wall. Could I fit a kitchen extractor that ducts vertically then right angles...
Back
Top