mains

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

mains

  1. M

    Aqualisa electric shower, mains water entry point blanking plug

    Hello, Im looking for help in tracking down a replacement part for an Aqualisa Energy 10.5 Kw Shower. The bit that has started leaking is the top facing mains entry point- Im using the bottom entry point. Ive attached a few pics of the part in question. It has the grey sleeve in the centre of...
  2. whitegold

    Mains Water Closet direct Flush valves still a rarity in UK?

    Just was at a caravan site in Lake District recently, which had some very interesting Delabie electronic tap and shower fittings, also direct WC flush valves which worked extremely well. Always wondered why these valves didn’t seem to catch on in UK when very many other countries never use...
  3. Alex1986

    Banging on mains water pipe, could an issue with the water mains cause it?

    Hi everyone, for the last few months ive had a random banging on the mains water pipe. This happens when nothing is being used, no taps, no washer, no toilet flush no boiler etc. Just a random banging and i can feel it vibrate allway through to mains pipe on the boiler. If i listen carefully...
  4. P

    LCS to new water mains

    Hi, I have an old steel water mains pipe (approx 45mm) that I need to connect to a new pehd water mains (25mm). I can't get at it to create a new thread so what's the best way of connecting the two? Cheers, Peter
  5. L

    Mains supply to mixer tap is pushing cold water to hot water pipe

    I live in an apartment block where generally hot water is supplied from the communal hot water cylinder and cold water to bathrooms is supplied from cold water tanks in the loft. It is a vented system. However, in a basement flat and a ground floor flat cold water supply to bathrooms is...
  6. A

    Kitchen tap Connection to mains issue

    Hi, I am replacing a kitchen tap and have run into some trouble when connecting the flexi hot and cold pipes to the hot and cold mains pipes. The connection end of the flexi pipe from the tap is a15mm, however the mains pipe I need to connect to is a 12mm. What connector do I need to buy? So far...
  7. S

    Gravity or mains shower?

    I have a dead 1990s Triton T70 shower and, for purposes of replacement, I'd like to know if it's mains or gravity fed. As it won't even switch on, I cannot get any water out of it so I can't just switch off water at mains and see if water still flows from the shower. I note that current Triton...
  8. J

    Strange grating noise when mains water is running

    Hi all, Got a strange grating noise when the mains water is running in a property I'm looking after. It's a ground floor flat, with a first floor flat above it, and both share the same mains water pipe, and I believe the stopcock behind the washing machine isolates all water to both properties...
  9. R

    Connecting gas fired generator to mains gas

    I've had an idea to use a gas fired generator running on mains gas to top up a large off grid battery bank when solar power is insufficient. Can anybody tell me if this is legal in the UK? Mains gas is much cheaper than electricity per kwh and the fact I've never heard of anybody doing the same...
  10. B

    Separate mains water connection query

    Hi I have a question, I want my flat to be separately connected to the mains water supply for water coming into my kitchen and bathroom instead of sharing the same pipework as my neighbours. Is this doable and if so is it the water board who will carry this out or a plumber? My flat has shared...
  11. D

    Electric Shower to Mains

    I currently have an 8.5kw electric shower on a gravity fed system in bathroom which doesn't give great flow when hot turned up but to get a 10mm cable to fuse board would be really difficult at best (I've checked and on 6mm at the minute) I would like a mains shower however changing to unvented...
  12. K

    Mains boost pump in top-floor flat

    Background I have a small one-bedroom flat in the roof space in a victorian house. There are three floors below and each floor has a single one-bedroom flat. The mains pipe bringing water into my top-floor flat is 15mm copper pipe. There is a water meter in the flat and a stop valve. There is...
  13. B

    electric shower vs. mains from dual cylinder submersion heater

    Hello, and thank you for reading. My partner and I have just purchased our first property that came with a dual cylinder electric water heater, and an electric shower in the bathroom. As it happens, the shower needs replacement, and we were thinking of removing the electric shower (Mira Sport)...
  14. A

    Mains water pressure and water softener/ leaking manifold

    Good morning I installed a Harvey’s water softener recently. Have a semi detached property with 3 showers and a 2 toilets with a mega flow cylinder 25mm mains pipe work with 22mm onwards. I put the softener before the prv which was pre installed with the unvented cylinder as the rep said...
  15. A

    mains pressure lower than minimum combi system pressure

    We have a vaillant combi boiler that over ~ 2yrs loses a bit of pressure, and recently after 2 weeks away and no use the system would not fire and errored with F75. We attempted to refill, but the mains pressure is only 1.0bar, and the combi needs more than that to light. I ended up removing...
  16. E

    Connecting to black rubber mains pipe

    I have a cold mains in that is a black flexible rubber looking pipe. Please see photo 1. It is currently connected to a 22mm stopcock. I’d like to send it 90 deg to the right. This is so I can lower the shelf above it and have the mains come in at a more convenient place. See photo 2 (with...
  17. J

    Bath tap mains fed or from tank

    Hi guys I'm wanting to install an electric shower in my new property what's the easiest way to check it bath tap is coming from mains ? The mains stop tap is located near the toilet in the room underneath me, when I switch that off it shuts all cold water off for every tap in the house. If I...
  18. Z

    Mains pipe in pitched roof??

    I need to get a 22mm mains to an unvented tank in my loft. Is an old house and the first part of the roof is pitched and sloping from the inside. The easiest way to get it into the loft is straight up the wall internally and then into the sloping roof the other side of the plaster board. This...
  19. R

    Can you have mains pressure cylinder on a back bolier?

    I have been told that I can't have a mains pressure unvented hot water cylinder with a back boiler on a wood burning stove as the heat source is uncontrollable. Is there a method to make the heat source controllable? I was imagining that if the cylinder was at its maximum temperature then if...
  20. A

    Thermostatic Mixer shower can be fitted to Mains and Gravity Hot?

    Hi all, I've been researching and planning a job for my home the past few days and a few pieces of advice would be welcome to help me along the way. I have a cloakroom toilet which has a toilet and a sink, where the sink currently is there is good room to put a small shower cubicle and a...