I am having a new gas boiler fitted for central heating only.
The pump needs to be part of and contained within the boiler.
What boiler do I need?
Heat only or Combinaton boiler ..... or?
Hello I’m hoping for some perceptive / input as I’m a long-distance landlord trying to unpick the best thing to do. Gas safety certificate was done on my rental flat (1st floor) which has a 10 year old Aviston E-combi EVO boiler. It failed based on rusting external flu components, which has...
Hi All,
Looking for a recommendation for a heat only boiler to replace my 30yrs old ideal boiler.
Any makes you would recommend and any to avoid?
Thanks
During an install of new boiler ('old' boiler died after 11-12 years) the system was "drained" but I guess maybe 90% of water was left in the (rather large) underfloor pipe system. What is the best way to tell how much inhibitor should be added in this case? (also taking account that system was...
I need some help and advice with a boiler issue. We have F29 and then F29 appearing on our new boiler. This happened after few days where water was dripping from the condensation pipe. Our regular gas engineer(who installed the boiler) was not available and will be in a couple of days. The...
Hello, We had an extension built seven years ago. Initially the builders' plumber connected the heating to the house system but this didn't work. The builder got him out again and he created a separate heating circuit from the boiler (ie one circuit for the house, the other for the extension)...
I recently purchased the ground floor of a detached Victorian property in Dorset. As part of the refurb, I will need a new boiler and about 94m2 of low level UFH. The flooring is currently very solid floor boards.
Hi,
Is it normal/usual or acceptable for there to be this much metal filings in a heating system following a new boiler installation only 5 weeks ago?
A supposed Chemical Flush was completed as part of the installation process.
Hi All,
Looking for a bit of advice on the best way to pipe this.
- 24kW Worcester regular boiler in kitchen, approx. 9 years old - unvented tank, zone vavles, pump, expansion is on first floor in airing cupboard
- Currently piped as S-plan.
- Hive controls.
- Would like to fit 6-zone...
I must be cursed
The new boiler that was fitted yesterday had a problem on commissioning, when the central heating was turned on the boiler fired but the pipework was only getting hot up to a certain point, it took the plumber a couple of hours to figure out what was happening, the problem was...
I am currently in the middle of a complete rennovation of my house and need some advice on what kind of boiler to get.
The house will have 4 bathrooms in total. One on the ground floor (shower), two on the 1st floor (en suite has a shower and family bathroom has a bathtub and seperate shower)...
Hi, had a new boiler fitted, didn’t notice at the time of fitting. you can see daylight around the overflow and condensate pipe, not an issue at present but should this be sealed to stop cold air coming in?
Hi, I have a Y plan open vent system, boiler 30+ years old, and requires replacement. My plumber is recommending fitting a new Viessmann 11kw System boiler in the current boilers position. The problem is he plans to run two new separate pipes fro the boiler to the hot water cylinder.
Once this...
The council are offering to update the fire and inefficient old radiators and replace the old fashioned boiler with a new combi one. They want to move the boiler from the tank cupboard in the bedroom to the much bigger walk-in wardrobe, presumably for convenience as there seems to be a gas pipe...
Looking for a quick bit of advice since I'm trying to wrap my head around what work I need done.
Right now I have an old conventional boiler that heats my hot water tank. The water tank has manual open/shut valve so that I can only heat the water tank and not the heating. I'm replacing this...
As above new boiler fitted and new Hive, Hive is set up correctly and works as it should but when it comes to scheduling on/off times via Hive the boiler doesn't cooperate, the radiators are set at 50 on the boiler but when the temp drops below this on the boiler it fires up. Now my way of...
Ive got a new replacement boiler to install and the Energy Saving Trust whole house boiler sizing is no longer being allowed to be used to correctly size new boilers.
Apparently there is an app you can use for room by room calculation anyone with a link.
I've looked online and keep just...
Just fitted a new boiler for customer have gone to gas rate when commissioning and batteries are dead in gas meter. Gas supplier won’t come out until 6th Jan. Does anyone have any ideas what I can do? Customer obviously needs heating and hot water over Christmas
Hi, i have had a new boiler installed and they have left the property without completing full scope of works.
Also have plugged the boiler into an extension lead on top of a toilet. (I will try and add a picture)
Any advice if this is ok or not please