Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

oil boiler

  1. Ant0912

    Fire valve external oil boiler

    We have an external grant vortex pro and the fire valve is on the oil supply line 1.4m away from the boiler . Read somewhere should be a distance of minimum 1 metre away . The sensor end is clipped into clip above the burner correctly . Just wondered if the fire valve should be closer or if...
  2. C

    Worcester Bosch Heatslave 26/32 (Oil boiler 2007) Flue perished

    Oily smell from boiler recently before failed. Great plumber sorted though when opened external baffle at front of sealed flue the internal spring like tube lining outer insulation had all perished. Barn conversion with thick walls (763mm). Worcester Bosch say Flue Kits are obsolete and...
  3. M

    Firebird Envirogreen Condensing Combi Oil Boiler spare part needed

    I have a "Firebird Envirogreen Condensing Combi Oil Boiler 26kW" a part has went and I can't find it anywhere, I was at every plumbers merchant near me but they all need to ring Firebird who are closed till next week. I wonder if anyone can help me find this part please? It's a pressure sensor...
  4. paulm05

    Grant combi oil boiler problems.

    My Grant combi oil boiler is giving me quite a headache at the moment. When I returned home last Friday I'd no heating or hot water. An engineer called the next day and diagnosed a faulty pressure switch. This was changed and everything seemed ok. However then the boiler began to lose pressure...
  5. D

    Oil boiler keeps tripping when it rains?

    We've had a Grant Thornton oil boiler for about 5 years and suddenly it trips the electricity when it rains? The unit is in a wood shed and the exhaust goes out the wall horizontally. I can't see any water ingress in the machine, so at a real loss......and very cold..!!!!
  6. P

    Grant Vortex 50/90 oil boiler with open air tube spigot

    Grant Vortex 50/90 condensing oil boiler where the air tube spigot over the fan is not connected to the existing flue, should this be closed off with a Reillo cover plate to stop vermin getting into the open fan motor.If is blanked over will need a further combustion test to confirm adequate...
  7. G

    Oil boiler not heating up

    I have a danesmore 20/25 oil boiler and it is firing up but it’s producing no heat to the water or the radiators My next door neighbour an electrician has checked the cylinder and thermostat and they all check out ok so he thinks the problem is within the boiler Can Someone help give me some...
  8. R

    Grant oil boiler problem

    Any advice welcome as plumber stumped Had 36-46 grant vortex utility boiler 7 years no problem recently oil tank move and tigerloop install (tank about 1m lower). 10 days later and boiler either doesn't fire or fires stops, fires runs splutters stops. Most it runs now is 10 mins, but that's...
  9. Ant0912

    Flow & Return firebird C26 combi oil boiler

    Hi, can anyone tell me which pipes are flow and return please. I removed old leaking 2008 C26 firebird oil boiler in June . We have now completed damp proofing works & I need to extend these 4 pipes to go through the wall and into a new boiler room. This area will then be stud wall and...
  10. T

    Oil Boiler and System upgrade

    Hi All, We have finally decided after a bit of a persuasion to have installed a utility room in our garage that currently houses our oil boiler. Initially we thought the boiler may stay in place but after discussions with the builder we would have to move the boiler to replace the floor and...
  11. R

    Advice for replacement pool oil boiler

    I've a client with a rusty 20yr+ old Certikin 180 (44kw) oil pool boiler that needs changing. Certikins replacement looks like it is the exact same boiler. It has a riello r40 burner and non condensing 85% efficient boiler... Oftec say it wouldn't be compliant and would have to contact Building...
  12. A

    External Oil Boiler recommendations

    Hi, I'm looking to change our boiler as part of some general house renovations. Could anyone recommend one that's going to be ultra reliable? I'm seeing lots of firebird problems on these forums, not so many Worcester Bosch issues. Are they worth the extra outlay? Thanks Alan
  13. W

    Firebird oil boiler hot water

    My firebird oil boiler hw supply is luke warm, but does heat up slightly when run if the ch is on at the same time. Is this a faulty diverter valve? If so could I replace this myself as I've heard they're expensive to fix. Tia
  14. D

    outside oil boiler fitted not correctly what to do next

    we had a grant condensing boiler fitted last year, the lad works for a heating company and said would fit it. when he did he put the pipes all through the flue hole of the last inside boiler we had copper pipes all laid on top of each other. there was an electrical cable running through a...
  15. D

    oil boiler overflow dripping

    Hi, We have a Grant oil combi boiler. Only 3 years old. Been a right pain. Already had expansion vessel replaced and the 3 bar PRV and another thing that I have forgotten name of, but it has a load of copper mini pipes is a square loop. Then when it was really cold the overflow started chucking...
  16. S

    De Dietrich oil boiler manual

    De Dietrich oil boiler Looking for the manual or draiwings of the attached De Dietrich oil boiler. I will appreciate if somebody knows the model name. Thanks in advance. Sandouraki
  17. S

    Camray 5 Combi Oil Boiler locks out on hot water demand

    Having a few issues with my combi boiler, its 14 years old now and due to be replaced as we are building extension, but need to get another 10 months out of the combi yet! Was having pressure and lockout issues and the relief vale had activated couple times, expansion tank is fuel of water so I...
  18. Crossfingers

    Oil boiler dripping hot water

    Please help Our Grant Vortex Pro oil combi boiler seems to have developed a drip from some sort of valve where it looks like there's a limescale build up. There is no water at all from hot tap and no pressure in the boiler. The heating works fine however. Is there something I can do or should...
  19. Crossfingers

    Oil Boiler installation

    Hi What are the regulations around installing a second hand oil combi boiler, am I right in saying they have to follow manufacturers instructions and building regs? Had people install on and it's positioned where I can't take the rear cover off to reach the condensate. The installation...
  20. M

    Oil Boiler gets too hot

    Hello everybody! I have little issue, and hope you will be able to help: I have very old oil boiler on conventional system. What happens is: When i turn central heating on, boiler is heating for about 1 hour, what happens at the end is pipes sound really loud(loud crackling sound) and overflow...