Hi All,
Combo Gas Boiler - Immergas Zeus Mini
I’m hoping you can maybe help me with an intermittent issue I’m having with my Immergas Zeus Mini Combi Boiler.
It works for weeks and then has a sporadic issue with igniting the boiler? I’ve uploaded a video so maybe you can take a Quick Look to...
Hello Plumbers
I’ve replaced a 540mm high cast iron rad with 740mm high, like for like but still a 20mm valve extension was required.
All was ok until I've spotted a v small leak (like 1 drip per hour) between the valve nut and extension piece.
So I suspect I just need more PTFE + compound...
Do any of you guys use this type of reducer?
It doesn’t have an olive and the bottom part of the brass compresses onto the pipe by the looks of it and the top is removable.
I haven’t used them before tbh.
I can only seem to find the 3 part versions by me.
I have a "Firebird Envirogreen Condensing Combi Oil Boiler 26kW" a part has went and I can't find it anywhere, I was at every plumbers merchant near me but they all need to ring Firebird who are closed till next week. I wonder if anyone can help me find this part please? It's a pressure sensor...
Some advice needed please re a 3 year old combi gas boiler. The hot water works but no heating. A gas engineer was already booked to do the annual safety check before the fault developed. He said the boiler is ok with no fault. He said there must be a leak under the floor boards causing hot...
I am in need of a spark generator 60080/002 part number 003939 for a very old Ideal Mexico Super RS40/60 boiler. All of the online retailers indicate obsolete not in stock. Can anyone recommend where I could purchase new or refurbished?
Hi guys
What connection goes on to the part floats please? It looks like it should be a compression to me rather than tap connector?
I’ll add a pic
Cheers
Hello,
Have had a leak on my UFH manifold. Originally incorrectly diagnosed as being the nuts/washer to the pump, it now looks like it's coming from this thermostatic valve.
Have tried googling "ufh thermostatic valve" and none of them look like this or have connectors like this (guessing part...
Our Adey product range includes an assortment of award-winning filters, chemicals, and water testing solutions. These products, trusted by heating engineers worldwide, are designed to shield your heating system from boiler breakdown, decrease carbon emissions, and ultimately, reduce energy...
Looking to see what iron pipe part can fit a 10mm ball joint? In this pic there is a part that connects the ball joint (or whatever they are called) to the 1/2 inch pipe. I am looking to connect to a 3/4 inch pipe. Are there any threads that do this? Thanks
I have been told that in North...
Hi,
I have a radiator which is unbalanced; I believe due to a missing outer part, please see the attached images. Is the missing part called a Flange? Any advice where I can buy this part? Thank you
Struggled with an element that was far too wide to come out of the aperture (how was it ever put in ?) I had to cut one loop. After some brute force the head broke off leaving the broken ends of the element protruding. I wiggled half of it out at which point the other half fell back into the...
This is doing my head in, so I am turning to the experts here for any wisdom...
In the last couple of days I have very low cold water pressure in my downstairs utility room and downstairs bathroom (they back on to each other). The main cold feed (kitchen tap) is normal pressure. And all the...
Hi All,
I am looking to purchase this part, if anyone has one or can point to to where I can purchase one then I would be grateful, as local to NN10 would be ideal.
3/8" x 1/2", MPT x FPT Connection, PVC Construction
Thanks all.
Hey folks, I'm wondering if someone could possibly help, I'm looking for a possible part number b4 I call ideal in the morning, I fitted an Ideal vogue 6years ago so it's generation 1 vogue c32, I also fitted a RF wireless controller (prt4) The reciever part plugs directly onto the boiler...
Hi everyone, I have been searching the Web for a spare part for a Worcester 35 cdi ng boiler that is obsolete. I can't find one anywhere and its looking more and more likely I'm doomed . The part is the door extrusion seal 87161031280. I have sold my house STC and this has just happened , so...
Hi, one of the two hooks on my toilet Torbeck fill valve has broken, and so the float can't connect. I've bought a new fill valve, however it's incredibly difficult to access underneath and replace the whole valve. I therefore just want to replace the plastic part that has the two hooks...
got new oil and tried to start my reillo g3b oil burner ,when it idnt fire and went to lockout i bleed the pump and check the nozzle ,and eventually took apart the pump to find lots of black oil slug around the oil pump.so i cleaned all the stuff of and cleaned through the pump and the only...
Hi,