Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

pump

  1. M

    Efficiency of air source heat pump water cylinders

    Does anyone know the efficiency levels of the unvented hot water cylinders with a heat pump on top with vents to get the air in to it. I think I'm correct in saying a normal direct unvented cylinder will be 1kw of electric to 1kw of heat
  2. Inverness

    Riello oil pump

    Hi. Is it possible to repair a leaky oil pump? Or best to get replacement??
  3. B

    To add a Negative or Positive pump? Same level as tank but shower

    Hi, Had a bathroom renovation done, new shower & bath. Unfortunately the new shower with narrow pipes & joints, splitter tap for fixed head & removeable etc. does not have the same flow rate as the old, actually now fixed head unusable, dripples & removable barely better but can be used. Use to...
  4. Inverness

    Riello oil pump

    With a riello oil pump thats for r 40 riello burner can you fit this to rdb1 50/70sh? The solenoid nut won't reach to screw on? Any advise
  5. Inverness

    Riello oil pump

    What is the difference between the 2 riello oil pumps that you can buy they both look the same but the only difference I can see. Where the solenoid is fitted there is a metal plate where the other doesn't.
  6. M

    Back boiler not heating downstairs radiator multihead 3 pump

    Hi I had my heating on for a few days all of a sudden there was no heating in downstairs radiators, when I turn the heating on it kicks in then turns of after 5 minutes. I have also turned up. The upstairs is heating up and pump is hot, i have bleed downstairs radiator , boiler was serviced in...
  7. P

    Baxi 105e pump head removal

    Hope you confirm something’s for me, boiler calls for how and ch but am not sure if pump is rotating, have checked if it’s stuck via inspection cap on pump which is ok. 240v at pump and on pcb so that’s ok. Can someone tell me how I check if it’s rotating, if not it states drain primary circuit...
  8. G

    Asked to notify DNO of heat pump installation

    Recently had job where could not get Electrical Installation Certificate completed because we had not got approval from DNO for the installation of 4 7kwDaikin air con units. seems they sometimes are not classified as heat pumps, but trying to get clarity. What have you found>
  9. P

    Manual pump to suck air bubbles out of tap?

    Having airlock problems with our hot tap: when is is running we hear bubbling and sometimes it stops completely. We can get it running again by running the cold tap fast at the same time. We are not on the mains. Our plumber used a wet and dry vacuum cleaner to pull water through once, is...
  10. M

    Heat pump hot water cylinders

    Has anyone fit the hot water cylinders with a little heat pump on the top that has ducts to bring inside and outside air in to the unit. Piping up wise is it just the same as a normal direct cylinder?
  11. davidwf

    W-plan pump run on

    Son recently moved into a 20 year old house with what appears to be a W-plan system using, I think a Worcester Bosch Greenstar gas boiler He noticed that the rads were getting hot when the HW was on and I diagnosed the 2 position diverter valve (not 3 position valve!) was well and truly seized...
  12. F

    Damped oil pump pressure gauge recommendation

    I have 2 oil pump pressure gauges, a Nu-Way un-damped one that I have had for well over 30 yrs and no name brand that the glycerine is going white and leaking. Can anyone recommend a good damped one. Ta
  13. I

    Heat Exchanger with AGA and heat pump

    Hi All I have a client asking whether they can still use the AGA to heat rads once the air source heat pump is in. I think it is possible using a heat exchanger so the low pressure AGA and high pressure heat pump systems don't connect. I've seen it done on biomass systems but wonder what the...
  14. J

    How can I check if my pressure pump is working ?

    Hi Guys , Had a valliant engineer out as I could not add any water to my boiler and it’s sitting on 1bar when I used to have more than this and could easily top the boiler up with the two switches underneath. I live on the fourth floor and when I moved in we had a brand new GRUNDFOS Type...
  15. Dan

    Mitsubishi Opens A New Heat Pump Training Centre

    Mitsubishi has opened a new heat pump training centre at its’ base in Scotland as demand increases for greener ways to heat our homes. Heating our homes accounts for around 38% of all gas use in the UK and each gas boiler can put into the atmosphere approximately 2 tonnes of carbon each year...
  16. K

    UK Advice on waste water pump in first floor flat

    Sorry if this is stupid question. We have waste water pump in our first floor flat (not sure what it is called)? It failed and wouldn't drain waste water from shower, we found out too late and the water had drained through the ceiling into the property below us. Probably a bit of stretch but...
  17. N

    Water pump to regulate high pressure?

    Hi, I'm looking for a water pump to pump water from a storage tank at a constant 3 bar pressure. It's at a campsite I run that's at the bottom of a long, steep hill. We struggle with very high and often fluctuating (around 7 bar) water pressure, which wreaks havoc with our water heaters. I've...
  18. jamespipe

    Plumber recommendation for heat pump HWS installation

    Hi, My current hot water system needs to be replaced. Anyone got any suggestions or can recommend any plumbers around Derrimut area that won't rip me off? An office guy recommended me to apply for government rebates and get it installed through timetosave.com.au. How reliable is this...
  19. T

    Shower Pump on air to water Unvented Cylinder?

    Hi, I'm in my new build 2 years and the shower pump has died. I have an air to water unit downstairs is in the utility which I've been told is unvented and pressurised. The cold water feed into this cylinder is from the attic tank, not the mains as I turned off the mains stopcock to see if hot...
  20. MrGatch

    UFH Pump Question - Do I need it?

    We have a three zone heating system plus water cylinder (OSO Super S 250L) on an Valliant EcoTec 637. Two CH zones and a UFH zone. Boiler is rarely at maximum power rating, even at full tilt. The UFH zone has it's own pump and the other two zones (three storey house) are just pumped from the...

We recommend City Plumbing Supplies, BES, and Plumbing Superstore for all plumbing supplies.

Back
Top