Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

system

  1. P

    Replacing Immersion tank with energy efficient system

    I am moving into an all electric small flat which has an Elson Opal 144ltr immersion on eco 7. However, the bathroom has been modernised with an electric shower and bath removed, so now ony a bathroom and kitchen sink needs hot water. I was wondering whether the immersion tank could be removed...
  2. P

    water pressure problem, unvented system

    I'm trying to sort out a problem with low water pressure at my elderly parent's house where they have an unvented system. I got a plumber in about a month ago who repressurised the system, after which it seemed better. However there still seems to be a problem, which is most noticeable with the...
  3. H

    Central heating system cleaning

    Hi all, I have added a bottle of Fernox F3 into my towel radiator upstairs, I have run the heating for a good few days now. I have bleed off points downstairs I can attach a hosepipe to drain the system. Question when all the water has drained out can I leave the hosepipe on and fill the system...
  4. T

    New plumbing & heating system advice

    Hello, I'm installing a new central heating & plumbing system and just wanted to run through my design choices to make sure I haven't overlooked anything! It's a 2 bed, 1 bathroom semi-detached house. These are the proposed appliances: WC, Basin, Bath, Shower, Bath, Washing Machine, Kitchen...
  5. T

    New plumbing & heating system advice

    Hello, I'm installing a new central heating & plumbing system and just wanted to run through my design choices to make sure I haven't overlooked anything! It's a 2 bed, 1 bathroom semi detached house. These are the proposed appliances: WC, Basin, Bath, Shower, Washing Machine, Dishwasher...
  6. M

    One pipe system condensing boiler.

    Would a one pipe system work efficiently on a condensing boiler as the return type would likely be below 54c all the time. So the boiler would run in condensing mode. Alot of condensing boilers don't run in condensing mode.
  7. B

    Is there a flexible pipe suitable for a secondary hot water circulatory system?

    I'd be grateful for some advice please. I'm doing a stable conversion which requires a secondary circulatory system. The plumber (yes, he is qualified) initially didn't realise this and when questioned, didn't actually appear to know what a secondary system was! He did come back to install one...
  8. P

    Changing from system to combi boiler with under floor pipework.

    Wondering should i change a system boiler with a combi if I have underfloor pipes in a single storey 2 bed 90s bungalow There are only 9 bungalows in the close and I was told 2 of these had leaks in floor when they changed to a combi by a neighbor. He said as he was an engineer he would not...
  9. S

    Closed system top up fed by domestic storage tank.

    I know of multiple estates built during the celtic tiger where the closed system heating is topped up by teeing into the cold feed to the copper cylinder using a check valve and expansion vessel left permanently connected. Recently went to one of these houses just to fit a new tap, but...
  10. F

    Open vented system, No HW, CH works fine, BAXI 80HE boiler shows Dry Fire after every restart

    Hi, I have an open vented system with Cylinder and F&E tank in the loft. I have noticed for about 2 weeks now that the hot water has been gradually getting less hot and currently is only luke warm. I tried raising the termostat on the cylinder which does not seem to take any effect. I do not...
  11. S

    Toliet takes ages to fill up in system

    Wonder if some can help our toilet once the toilet has been flushed it takes ages to fill up before you can flush again any help please tks
  12. M

    Boiler in loft draining system/ refill

    Is there any extra procedures to take when draining and re-fillling a system with the boiler in the loft. High point. Thanks?
  13. T

    Air inside ideal Logic 24 boiler system

    Hi All, Anyone know the best way to get air out of an ideal Logic 24 boiler please, I have bled all of the radiators successfully starting at the bottom of the property, and also utilised the two bleed valves at the highest point above the boiler (photo attached) but there is still air bubbling...
  14. M

    1 pipe system, 2 downstairs rads not heating up properly.

    I have had a problem where 2 downstair radiators are not heating up the same as the rest of the radiators around the house, now previously i had an electric boiler which heated all the radiators just fine, but around a few years ago i had a gas one fitted and the radiators in the living and...
  15. K

    Understanding heating/water tank system

    Hi, We moved into a new property yesterday and are a little baffled by the heating/water tank situation. The previous owners unhelpfully left any kind of instructions/manual and therefore trying to figure out ourselves. We have what looks like a boiler/water tank system (coming from a standard...
  16. F

    Replacing an installed megaflow system with a combi-boiler when current boiler needs replacing

    Home owner looking for some advice pls. We have a megaflow system which we are considering removing as the tank takes up a lot of space and we don’t find we are using more than one shower or bath at a time. Our plan is to do this when the current boiler needs replacing (probably in the next...
  17. alanmcm

    Moving into a new home and boiler system is 17 years old

    My daughter bought her first home and was hoping to convert to gas but its not available in the area, so thinking a boiler upgrade is the better way to go. Just after some advice and rough costs involved, is it worth getting a pressurised system installed and a new boiler and oil pump? Heating...
  18. S

    Repiping Central Heating System Advice

    I am repiping my whole house and changing from combi boiler to a 30kW system boiler & 250Ltr or 300Ltr unvented indirect hw tank. Can somebody give advice on my rough plans/sketches for repiping my radiators using 22mm & 15mm. I have only shown the flow line as the return line will just be a...
  19. N

    Replacing a Radiator Valve on a Boilermate 2000 system.

    My daughter's place has a small water leak on a ground floor radiator valve. The radiator pipework is small diameter.i.e 8 or 10 mm. A plumber is coming back in a day or so to make necessary repairs. I am a little concerned as the house has a Boilermate 2000 on the upper floor and the...
  20. J

    Old un-pressurised heating system - top up valve

    Hi All, I hope you are doing well. I have old un-pressurised heating system and I need to top up the water but I cannot locate the bloody valve. Where is it? Is it in the attic? I also have this valve with black screw on top. Should this be opened or closed? Thank you