  1. D

    Single Radiator Stone Cold After System Maintenance

    Had to have an Auto Vent Valve changed today so system was drained down from the boiler, as this is higher than all the downstairs radiators I am assuming it was only the upstairs part of the system that drained? Anyhow, valve was changed and system refilled, started up on Hot Water only all...
  2. A

    vokera boiler (fault code A02 )

    do i need to drain system for replacing a high limit thermostat on vokera boiler (fault code A02 )
  3. F

    Choice of pipe for hot water secondary/recirculating system

    What plastic based / barrier pipe can you use in a hot water secondary/recirculating system. I note Hep20 and Polypipe make it clear in their specs it must not be used. Other than copper what do you use.
  4. N

    Where to put softener in water system?

    I live in Azerbaijan, the house has three full bathrooms and has had up to 7 people living there. We store about 5-6 tonnes of water - a necessity because we've had no mains water for the last 2-3 days. We currently have two plastic tanks but they are impossible to clean, so I am replacing them...
  5. P

    Replacing Immersion tank with energy efficient system

    I am moving into an all electric small flat which has an Elson Opal 144ltr immersion on eco 7. However, the bathroom has been modernised with an electric shower and bath removed, so now ony a bathroom and kitchen sink needs hot water. I was wondering whether the immersion tank could be removed...
  6. P

    water pressure problem, unvented system

    I'm trying to sort out a problem with low water pressure at my elderly parent's house where they have an unvented system. I got a plumber in about a month ago who repressurised the system, after which it seemed better. However there still seems to be a problem, which is most noticeable with the...
  7. H

    Central heating system cleaning

    Hi all, I have added a bottle of Fernox F3 into my towel radiator upstairs, I have run the heating for a good few days now. I have bleed off points downstairs I can attach a hosepipe to drain the system. Question when all the water has drained out can I leave the hosepipe on and fill the system...
  8. T

    New plumbing & heating system advice

    Hello, I'm installing a new central heating & plumbing system and just wanted to run through my design choices to make sure I haven't overlooked anything! It's a 2 bed, 1 bathroom semi-detached house. These are the proposed appliances: WC, Basin, Bath, Shower, Bath, Washing Machine, Kitchen...
  9. T

    New plumbing & heating system advice

    Hello, I'm installing a new central heating & plumbing system and just wanted to run through my design choices to make sure I haven't overlooked anything! It's a 2 bed, 1 bathroom semi detached house. These are the proposed appliances: WC, Basin, Bath, Shower, Washing Machine, Dishwasher...
  10. M

    One pipe system condensing boiler.

    Would a one pipe system work efficiently on a condensing boiler as the return type would likely be below 54c all the time. So the boiler would run in condensing mode. Alot of condensing boilers don't run in condensing mode.
  11. B

    Is there a flexible pipe suitable for a secondary hot water circulatory system?

    I'd be grateful for some advice please. I'm doing a stable conversion which requires a secondary circulatory system. The plumber (yes, he is qualified) initially didn't realise this and when questioned, didn't actually appear to know what a secondary system was! He did come back to install one...
  12. P

    Changing from system to combi boiler with under floor pipework.

    Wondering should i change a system boiler with a combi if I have underfloor pipes in a single storey 2 bed 90s bungalow There are only 9 bungalows in the close and I was told 2 of these had leaks in floor when they changed to a combi by a neighbor. He said as he was an engineer he would not...
  13. S

    Closed system top up fed by domestic storage tank.

    I know of multiple estates built during the celtic tiger where the closed system heating is topped up by teeing into the cold feed to the copper cylinder using a check valve and expansion vessel left permanently connected. Recently went to one of these houses just to fit a new tap, but...
  14. F

    Open vented system, No HW, CH works fine, BAXI 80HE boiler shows Dry Fire after every restart

    Hi, I have an open vented system with Cylinder and F&E tank in the loft. I have noticed for about 2 weeks now that the hot water has been gradually getting less hot and currently is only luke warm. I tried raising the termostat on the cylinder which does not seem to take any effect. I do not...
  15. S

    Toliet takes ages to fill up in system

    Wonder if some can help our toilet once the toilet has been flushed it takes ages to fill up before you can flush again any help please tks
  16. M

    Boiler in loft draining system/ refill

    Is there any extra procedures to take when draining and re-fillling a system with the boiler in the loft. High point. Thanks?
  17. T

    Air inside ideal Logic 24 boiler system

    Hi All, Anyone know the best way to get air out of an ideal Logic 24 boiler please, I have bled all of the radiators successfully starting at the bottom of the property, and also utilised the two bleed valves at the highest point above the boiler (photo attached) but there is still air bubbling...
  18. M

    1 pipe system, 2 downstairs rads not heating up properly.

    I have had a problem where 2 downstair radiators are not heating up the same as the rest of the radiators around the house, now previously i had an electric boiler which heated all the radiators just fine, but around a few years ago i had a gas one fitted and the radiators in the living and...
  19. K

    Understanding heating/water tank system

    Hi, We moved into a new property yesterday and are a little baffled by the heating/water tank situation. The previous owners unhelpfully left any kind of instructions/manual and therefore trying to figure out ourselves. We have what looks like a boiler/water tank system (coming from a standard...
  20. F

    Replacing an installed megaflow system with a combi-boiler when current boiler needs replacing

    Home owner looking for some advice pls. We have a megaflow system which we are considering removing as the tank takes up a lot of space and we don’t find we are using more than one shower or bath at a time. Our plan is to do this when the current boiler needs replacing (probably in the next...