    Newly fitted isolation valve keeps leaking

    Hi all, I fitted some new isolation valves on my bathroom sink pipes in order to screw in my new basin tap flexi-hoses. Hot water one is fine, though been having trouble with the cold one. It seems to pool over time in the olive/nut area shown in the picture. I tried several olives after a few...
  2. M

    What size/type valve is this for kitchen mixer tap

    Hi please can you help? What size/type valve is this? I previously asked a plumber and was given the wrong size:(
  3. T

    How to Open a TPR Valve

    Temperature and Pressure Relief (TPR) valve made by Reliance. How do you open and close it. I believe its a twist one. Do you just twist it anti-clockwise or do you have to pull it out a bit first
  4. A

    New toilet syphon fill valve clunk noise

    Never had water hammer clunk noise untill i had a new rimles toilet fitted a week ago, is there a more silent syphon/fill valve i could use, all the parts came with the new toilet therefore i am unsure of the brand. if any one has any ideas that would be appreciated since this sound is driving...
  5. vertexape

    Shower Valve Thermostat Fault?

    Hello, I fitted a shower last year that has two outputs, one standard shower, and another rainfall head in the ceiling. When I setup the valve control, I made the median temperature an acceptable warmth so that the dial was directly between hot and cold and in the center of the valves travel...
  6. davidwf

    blisters on flush valve seal

    Had a leaking flush valve in the cable operated Fluidmaster drop dual flush valve in the toilet cistern that initially turned out to be some limescale debris stuck between the flush valve (drop valve?) and its seat..... After removing the unit and cleaning it all out I noticed what I can only...
  7. D

    Isolating valve

    Is it good practice what I'm planning to do. I want to drain the central heating and then put 2 isolating valves on the flow and return in readiness for when I purchase another radiator and that way after doing a little bit of pipework I can just top the system up. I want to drain now while the...
  8. M

    Isolation valve with double check valve

    Does anyone fit these internally for outside tap installation? Instead of an isolation valve and a separate double check valve.
  9. M

    Viva full valve double check valve

    Do these fill valves have a double check valve in the tail? Seems to imply it in the technical.
  10. Ant0912

    Fire valve external oil boiler

    We have an external grant vortex pro and the fire valve is on the oil supply line 1.4m away from the boiler . Read somewhere should be a distance of minimum 1 metre away . The sensor end is clipped into clip above the burner correctly . Just wondered if the fire valve should be closer or if...
  11. D

    What valve is the flow

    Hi all I removed a radiator off the wall and forgot to note what valve was the flow as I'll be replacing with a new radiator with a trv. Without putting back and re connecting how can I tell what pipe is the flow and what pipe is the return because I assume the trv goes on the flow. Btw both...
  12. G

    Where does the bellows fit on a Grohe adagio single valveflush?

    I can't see whether the bellows which activates the flush is supposed to fit inside the opening at the top of the valve or press down on the edge. It doesn't seem to be aligned with the top so I don't know what's up with it.
  13. D

    Vent valve greenstar 35cdi compact how to get back inside

    Hi Took the vent valve off which has a spring clip and sits in the top right hand side of the boiler, particular to this install it's in a cupboard making access difficult on top of a step ladder and sliding into the cupboard. I have Drained the system. Silicone greased the new valve for...
  14. B

    Replace central heating gate valve with 2-port valve

    My house has a separate central heating loop that heats an annex. The annex loop has 3 x radiators (all with TRV), pump (manually switched) and a gate valve. The gate valve is very awkwardly sited, and difficult to operate, so I am wondering whether it is a good idea to replace this with...
  15. I

    Cleaning a Magnetic Filter without an isolation valve

    Hello All, We have a Vaillant boiler, it has an advanced protection kit fitted that gives it a 10 year warranty. My understanding is that this is essentially a magnetic filter that captures all the deposits before the enter the boiler and contaminate it, thus invalidating your warranty. I...
  16. G

    Leaking shower valve set

    I have a dripping shower valve. I have take away the face plate and at a complete loss at what to do. There's currently a bag sitting over it which isnt pleasing the family. Any guidance appreciated.
  17. J

    Replacement Diverter valve for obsolete tap

    Hi, I have a Bristan Matrix Bath Shower Mixer Tap, the diverter valve has been temperamental for some time and has finally failed with a split rubber washer. The tap is obsolete and spares are no longer available. (I have contacted Bristan.) The bath is built in and access to the tap is not...
  18. A

    Location of water meter with main shutoff valve.

    I am refurbing my bathroom & need to replace the dodgy main stopcock from the rising main. It is easily accessible and the job should be straightforward. I live in a first floor flat in a block of 6. When I contacted Yorkshire Water, to ask for a meter location, a rather shirty young man...
  19. T

    Ferolli boiler leaking water from gas valve

    I have a ferolli HE31C and it has developed a water leak that appears to be from a porous casing in the gas valve. I can not see where water even enters the gas valve as I presume the gas goes in the bottom and out of the top of the valve. To check this out I dried it off and put some sealant...
  20. F

    screw in direct cistern valve replacement

    Leaking toilet - needs replacement flush valve but existing screws direct into cistern not fixed with nurt and seal. How do I get this type of valve or is the thread size the same as the spigot and nut type so I get one of the latter and dispose of the nut & seal?