Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Wiring a salus t105rf to older Worcester ?? in the Plumbing Jobs | The Job-board area at Plumbers Forums

macka09

Plumbers Arms member
Plumber
Gas Engineer
Messages
1,238
Hi guys. Any advice on fitting the above stat to an older Worcester green star HE? The boiler is existing so already has it’s live neutral earth but the old room stat has been disconnected due to the house being required. Any help would be great thanks.
 
Which greenstar? You ok with electrics and safe isolation? I’m not 100% with why the Salus states 5a fuse rating?
Usually 5 core cable, taking a live and neutral from the boiler or spur to feed receiver, remove the earth cable as not required, the other 2 cables will be live supply (ls) and live return (lr). Neutral will not be required for a wireless stat.
 
Which greenstar? You ok with electrics and safe isolation? I’m not 100% with why the Salus states 5a fuse rating?
Usually 5 core cable, taking a live and neutral from the boiler or spur to feed receiver, remove the earth cable as not required, the other 2 cables will be live supply (ls) and live return (lr). Neutral will not be required for a wireless stat.
It’s the older R25 green star HE COMBI. I’m fine doing it but the instructions with the Salus are terrible. Also I didn’t see anything about a 5a fuse?
 
Com eg live from boiler

No eg call
 
Wiring same as what I’ve quoted, however I’ve been onto Salus website for the following:

07FA0A14-9400-4A12-9CC9-DA6551FC5955.jpeg
 
Is it the Greenstar HE with the computer/digital timer on the front or just the normal model?

If it's the latter as others have said there should just be a LS and LR, then neutral. LS, common, LR NO receiver.

The 5A is the switching load of the relay, not the load required for the receiver.
 
Is it the Greenstar HE with the computer/digital timer on the front or just the normal model?

If it's the latter as others have said there should just be a LS and LR, then neutral. LS, common, LR NO receiver.

The 5A is the switching load of the relay, not the load required for the receiver.

It is just the normal model.
So I just need to run a seperate 3 core to the receiver. LS, LR and neutral?
 
Which greenstar? You ok with electrics and safe isolation? I’m not 100% with why the Salus states 5a fuse rating?
Usually 5 core cable, taking a live and neutral from the boiler or spur to feed receiver, remove the earth cable as not required, the other 2 cables will be live supply (ls) and live return (lr). Neutral will not be required for a wireless stat.
It’s the receiver that I’m wiring up?
 
Is it the Greenstar HE with the computer/digital timer on the front or just the normal model?

If it's the latter as others have said there should just be a LS and LR, then neutral. LS, common, LR NO receiver.

The 5A is the switching load of the relay, not the load required for the receiver.
It says in the salus instructions it needs a 4 core going to the receiver? SL off. Live. SL on and a neutral
 
Unless I have the wrong information, then it shows a live, neutral, common and normally open, which on your boiler setup is: live and neutral from your boiler terminals inside on the pcb. Your other 2 wires go to Ls and Lr on boiler pcb and com and No at receiver.

Edit:

34FF0121-425D-47DA-9E3F-2629BCF9DD53.jpeg
 
Last edited by a moderator:
Unless I have the wrong information, then it shows a live, neutral, common and normally open, which on your boiler setup is: live and neutral from your boiler terminals inside on the pcb. Your other 2 wires go to Ls and Lr on boiler pcb and com and No at receiver.

Edit:

View attachment 39017
That isn’t the info I have for it. I can’t seen to upload the picture.
 
Ls to live
Ns to neutral
Link live to com
Lr to no
 

Similar plumbing topics

Thanks Shaun I will have a go at it on...
Replies
14
Views
2K
  • Question
Its a very ingenious but devilishly cunning...
2
Replies
25
Views
3K
Thanks for everyone's help. Hive is installed...
Replies
7
Views
3K
There’s a spare neutral next to ls in the...
Replies
19
Views
349
Defo the cartridge not seating, probably had...
Replies
10
Views
1K
Back
Top