Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss What we all working on this week ? in the UK Plumbers Forums area at Plumbers Forums

king of pipes

Esteemed
Plumber
Gas Engineer
Subscribed
Messages
6,156
I have a insurance job to try and rescue a poorly installed quad shower the customer wants to save the tiling if possible and has a few spare so fingers crossed it may work , the loss adjuster allowed em £1500 that will just about cover materials. Kop
 

Attachments

  • Screenshot_20191031-033038.png
    Screenshot_20191031-033038.png
    400.3 KB · Views: 209
  • Screenshot_20191031-033046.png
    Screenshot_20191031-033046.png
    420 KB · Views: 106
  • Like
Reactions: Dan
Boiler £492 + Vat - flue £69 - 29 + Vat Scott, I got the boiler & flue , Honeywell T4 , Magnaclean micro , chemicals , 6m of 22mm + 6m of 15mm , £180 piece fittings bucket , filling loop and 15mm salamander inline descaler for £1000. Cheers kop
 
Agreed mate I supposed they are aimed at rental and landlord type properties may be ? add a stat job done may not meet boilier plus but loads out there that don't and who is going to police it nowadays a the best bud . Kop
You can’t meet boiler plus with the mechanical clock and room stat as far as I know.
So you need Weather comp.
Or an external programmer/stat and tell the user not to touch the built in timer as it must be permanently on.

I fitted an Independant c24 recently for a landord, I used a Salus wireless room stat as it was the cheapest available. Doesn’t comply but like you say, who’s going to check.
 
You can’t meet boiler plus with the mechanical clock and room stat as far as I know.
So you need Weather comp.
Or an external programmer/stat and tell the user not to touch the built in timer as it must be permanently on.

I fitted an Independant c24 recently for a landord, I used a Salus wireless room stat as it was the cheapest available. Doesn’t comply but like you say, who’s going to check.
That's what I did mate timer on constant and Programmable Honeywell T4 which meets boiler plus bud .
[automerge]1587622515[/automerge]
Better picture Scott
 

Attachments

  • Screenshot_20200422-185305.png
    Screenshot_20200422-185305.png
    252.5 KB · Views: 27
  • Screenshot_20200422-190206.png
    Screenshot_20200422-190206.png
    324.4 KB · Views: 32
Last edited:
My first biggish job near completion since lockdown started stripping out Thursday and Friday last week , this shower room needed turning round quickly so went for multi panel to blend in with the existing tile that was installed 5 years ago and still looking good , the Victoria plumb shower and tray installed hadn't faired so well was leaking badly and looked shabby , I installed a Aqualisa Zuri smart shower with the processor box installed above in the loft connected to a Viessman 100 combi and Qualitex shower tray and wetroom glass, just the wiring, commissioning, lagging , and the clearing up to do today so 4.5 days which I think is reasonable cheers chaps keep safe . Kop
 

Attachments

  • IMG_20200611_161234.jpg
    IMG_20200611_161234.jpg
    116.3 KB · Views: 27
  • IMG_20200612_134110.jpg
    IMG_20200612_134110.jpg
    107.1 KB · Views: 27
  • IMG_20200615_162825.jpg
    IMG_20200615_162825.jpg
    70.1 KB · Views: 30
  • IMG_20200616_164111.jpg
    IMG_20200616_164111.jpg
    81.6 KB · Views: 26
  • IMG_20200616_145550.jpg
    IMG_20200616_145550.jpg
    166.2 KB · Views: 31
My first biggish job near completion since lockdown started stripping out Thursday and Friday last week , this shower room needed turning round quickly so went for multi panel to blend in with the existing tile that was installed 5 years ago and still looking good , the Victoria plumb shower and tray installed hadn't faired so well was leaking badly and looked shabby , I installed a Aqualisa Zuri smart shower with the processor box installed above in the loft connected to a Viessman 100 combi and Qualitex shower tray and wetroom glass, just the wiring, commissioning, lagging , and the clearing up to do today so 4.5 days which I think is reasonable cheers chaps keep safe . Kop

Panels actually look decent. Which ones you use and how do you attach them?
 

Attachments

  • Screenshot_20200617-193412.png
    Screenshot_20200617-193412.png
    204 KB · Views: 23
Hi KOP, I was told by aqualisa that a flow limiter can damage the pump so could only go down to 10l/min (if I remember correctly) - what do you go down to and have you had any problems?
I too have wanted to hold the bugger back occasionally!
 
Hi KOP, I was told by aqualisa that a flow limiter can damage the pump so could only go down to 10l/min (if I remember correctly) - what do you go down to and have you had any problems?
I too have wanted to hold the bugger back occasionally!
9 litres a minute bud I will contact Aqualisa and check ? after second thoughts I may adjust where I limited the flow to the incoming supplies that way theres no back pressure , the stainless steel grate is the problem luckily my brother is the production manager in a factory that produces sheet metal products so hes going to fabricate a new one with 40 more holes in then restriction can come out ??? cheers Kop
 
You’ll probably have a market for those grids! I find positioning the riser rail/fixed head makes a hell of a difference to waste removal - but of course this has to be run past customer, if it wasn’t for them this job would be easy.
 
Update chaps after talking to Aqualisa technical , I have adjusted the processor control unit to HP eco mode from combi mode this reduces the flow by 2 litres a minute and removed the flow limiter it is not guaranteed to work faultlessly and can fluctuate slightly on temperature but a 2 litres a minute saving is worth trying also getting a grate made with 40 extra holes so should help. Kop
 

Attachments

  • IMG_20200618_113022.jpg
    IMG_20200618_113022.jpg
    151 KB · Views: 24
  • IMG_20200618_104935.jpg
    IMG_20200618_104935.jpg
    180.4 KB · Views: 30
  • Screenshot_20200618-183059.png
    Screenshot_20200618-183059.png
    95.6 KB · Views: 22
Started a bathroom upgrade this week new owner hates the assisted bathroom look and it's fixtures and fittings so a full strip and new tiling is taking place, updating everything . Kop
 

Attachments

  • MVIMG_20200622_085813.jpg
    MVIMG_20200622_085813.jpg
    127.8 KB · Views: 20
  • IMG_20200622_085827.jpg
    IMG_20200622_085827.jpg
    68.6 KB · Views: 20
  • MVIMG_20200623_100728.jpg
    MVIMG_20200623_100728.jpg
    122.2 KB · Views: 22
  • IMG_20200623_100732.jpg
    IMG_20200623_100732.jpg
    144.7 KB · Views: 20
  • IMG_20200623_100739.jpg
    IMG_20200623_100739.jpg
    103.5 KB · Views: 23
Looks good Scott you do the prep eg hardie ? And Mira shower ?
 
I hate bathrooms 😄
This is the tray I asked for advice on another thread. Went for SBR and flexible tile adhesive in the end.
View attachment 44319View attachment 44320
Looks tidy Scott 👍 sorry bud must of missed that one I would have done the same . What were the wall panels made of ???? Kop
[automerge]1593064039[/automerge]
Got a few tiles up it all taking shape nicely . Kop
 

Attachments

  • IMG_20200624_164605.jpg
    IMG_20200624_164605.jpg
    81.3 KB · Views: 24
  • IMG_20200624_164553.jpg
    IMG_20200624_164553.jpg
    126.9 KB · Views: 25
Last edited:
New posts

Similar plumbing topics

  • Question
Very hard to follow your post Tina. What...
Replies
18
Views
4K
  • Question
Yes, The size of the external expansion...
Replies
17
Views
10K
No, I believe you absolutely. My own problem...
Replies
9
Views
246
  • Question
The customer had a Mira Sport they had bought...
Replies
14
Views
223
    • Like
  • Locked
Have another guy working for me but on this...
2
Replies
25
Views
5K
Back
Top