Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss Which UFH wiring centre is this in the Central Heating Forum area at Plumbers Forums

Messages
149
Just put a new boiler in a property that only has UFH and old boiler switch live came from the UFH wiring Centre which is 230 volt. Problem is now that the new boiler sw/l is only low voltage so cant use the same cable. I'm trying to find out what make of unit this is so I can get some info on it but all I have is Pipe 2000. Would anybody know who makes this unit
 

Attachments

  • Screenshot_20200911-204925_WhatsApp.jpg
    Screenshot_20200911-204925_WhatsApp.jpg
    349.2 KB · Views: 41
  • Screenshot_20200911-204905_WhatsApp.jpg
    Screenshot_20200911-204905_WhatsApp.jpg
    147.6 KB · Views: 35
use a relay

a1 switch live from the ufh
a2 neutral

then use the contacts to switch the boiler
 

Similar plumbing topics

Thanks Shaun I will have a go at it on...
Replies
14
Views
2K
I have a home with an oil boiler in a garage...
Replies
0
Views
637
That's what I originally thought... I think it...
Replies
21
Views
3K
You will need a check valve to stop reverse...
2 3
Replies
61
Views
7K
The Baxi 105e doesn’t recommend 3 wires, it...
Replies
5
Views
1K
Aquarius
A
Back
Top