How to turn off cylinder | Central Heating Forum | Plumbers Forums
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss How to turn off cylinder in the Central Heating Forum area at Plumbers Forums

Hi, I've recently moved into a new house with a traditional heating system (header tank in loft, cylinder in airing cupboard, and boiler). I'm having a problem in that the hot water cylinder won't turn off completely at all at the moment, even when the central heating is switched to 'off' at the controls. This will turn off all the radiators except the one in the bathroom which just keeps going forever. Is there any way I can turn off the heating manually? E.g. there is a plug socket with a switch in the cupboard with the cylinder, but I don't know what switching this off will do. I don't want it to keep using up gas constantly, and the sound of it being on throughout the day and night is a little irritating. Any advice would be much appreciated! I've attached some images of the inside oft he cupboard with the cylinder if that helps.
Many thanks,
Peter
 

Attachments

  • 20220107_095753.jpg
    20220107_095753.jpg
    258.7 KB · Views: 36
  • 20220107_095750.jpg
    20220107_095750.jpg
    415.4 KB · Views: 36
  • 20220107_095757.jpg
    20220107_095757.jpg
    330.4 KB · Views: 39
Hello Peter,

  • check the immersion heater, it may be on, so therefore the water is always heated, and turned on.
  • the cylinder thermostat isn’t strapped to the cylinder properly, and looks like the wrong cable has been used, and it’s located too far down the cylinder.
  • Where the programmer is located on the left hand side, trace that conduit, the wiring is in there and should go to a switch.
  • Is the boiler firing?
 
Make sure your programmer (time switch) isn't set on constant, picture of it would be useful.
If it is in a switched off position you maybe have problem with the hot water motorised valve.
 
Hi, thanks for the replies. I've attached a picture of the programmer, if that helps, and the white box below it. The only wire from the programmer goes into that box, so I'm not sure if it links to a switch I could turn off. In addition to the plug socket on the opposite side of the wall to the programmer, there is also a fuse switch just above it - both have wires that go into the floor, so I'm unsure what they connect to.

Do you think it would be safe to try turning each of those off to see if they turn off the system? Or might those switches be linked to something important (I don't want to do anything disastrous by mistake!).

Many thanks again,

Peter
 

Attachments

  • 20220107_110949.jpg
    20220107_110949.jpg
    295.9 KB · Views: 31
  • 20220107_095757 (1).jpg
    20220107_095757 (1).jpg
    330.4 KB · Views: 27
Your programmer is in the off position so if boiler/pump still running chances are motorised valve problem.
You will need a multimeter and be competent to use it to check it out.
Should not be any problem turning off fused spur to check if it turns heating off.
 

Similar plumbing topics

N
If it takes ages to heat up I’m guessing due...
Replies
2
Views
1K
Replies
3
Views
759
That’s why I think they’ve done it the wrong...
2 3
Replies
61
Views
9K
    • Like
From this post, I think you’ve got a good...
2
Replies
47
Views
6K
Is your hot water discoloured ? Has the...
Replies
19
Views
2K
Back
Top