Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

Discuss What we all working on this week ? in the UK Plumbers Forums area at Plumbers Forums

king of pipes

Esteemed
Plumber
Gas Engineer
Subscribed
Messages
6,156
I have a insurance job to try and rescue a poorly installed quad shower the customer wants to save the tiling if possible and has a few spare so fingers crossed it may work , the loss adjuster allowed em £1500 that will just about cover materials. Kop
 

Attachments

  • Screenshot_20191031-033038.png
    Screenshot_20191031-033038.png
    400.3 KB · Views: 209
  • Screenshot_20191031-033046.png
    Screenshot_20191031-033046.png
    420 KB · Views: 106
  • Like
Reactions: Dan
Been servicing this boiler for the last 6 years but recently it's developed a series of problems, it wasn't installed vey well and the builders were not the best and didnt finish off very well , I've upgraded to a Ideal Vogue 32kw with their halo control which is very similar to a nest so far quite impressed , finishing off today upgrading the gas removing a redundant section, fitting a new rad and altering some poorly fitted pipework then cleaning the system.
 

Attachments

  • IMG_20220523_112809293.jpg
    IMG_20220523_112809293.jpg
    299.5 KB · Views: 24
  • IMG_20220523_113937041.jpg
    IMG_20220523_113937041.jpg
    303.6 KB · Views: 23
  • IMG_20220523_091212053.jpg
    IMG_20220523_091212053.jpg
    324.8 KB · Views: 27
  • IMG_20220524_171318447.jpg
    IMG_20220524_171318447.jpg
    459.4 KB · Views: 25
  • IMG_20220523_091206154.jpg
    IMG_20220523_091206154.jpg
    297.9 KB · Views: 24
  • IMG_20220524_171307538.jpg
    IMG_20220524_171307538.jpg
    315.1 KB · Views: 20
  • IMG_20220524_171300113.jpg
    IMG_20220524_171300113.jpg
    391.8 KB · Views: 21
  • IMG_20220524_171457909.jpg
    IMG_20220524_171457909.jpg
    264.5 KB · Views: 25
Hmmmm
 

Attachments

  • FC637B92-FC8A-4B07-BB6F-568FD6E5A27C.jpeg
    FC637B92-FC8A-4B07-BB6F-568FD6E5A27C.jpeg
    446.9 KB · Views: 33
  • 14DA2F49-6811-4C91-AE4E-B65756762514.jpeg
    14DA2F49-6811-4C91-AE4E-B65756762514.jpeg
    568.7 KB · Views: 32
Why ???? FFS seen it all now its leaking from the inner seals I'd say 🤣🤣 kop

Zero fall on the flue and seals fecked funny part is it’s been serviced every year this year was a good lad and flagged it up for repair lucky
 
I like the vogue, The fact you cant range rate it, the valves underneath and crappy drain off let it down for me
I used their Halo on this one otherwise or it's weather comp or connected via open therm with a combi pack 4 which ever suits best , added my own drain point and there's one on the filter, valves aren't the greatest but ok if there used and moved and freed up, it's now completed the warranty and paperwork to do and print happy days 😉👍. Kop
 

Attachments

  • IMG_20220526_113837745_HDR.jpg
    IMG_20220526_113837745_HDR.jpg
    1.1 MB · Views: 27
  • IMG_20220526_165915031_HDR.jpg
    IMG_20220526_165915031_HDR.jpg
    1.2 MB · Views: 23
  • IMG_20220526_105711089.jpg
    IMG_20220526_105711089.jpg
    305.3 KB · Views: 22
  • IMG_20220526_105717370_HDR.jpg
    IMG_20220526_105717370_HDR.jpg
    386.4 KB · Views: 22
It’s gotten worse before it’s gotten better :D

All done not the way I would of like to do it but it’s all safe
 

Attachments

  • 4B10745F-6936-47FE-A3D4-D74FE03C4C4C.jpeg
    4B10745F-6936-47FE-A3D4-D74FE03C4C4C.jpeg
    389 KB · Views: 24
  • C13EB7ED-5473-4295-B23D-D5B369217CBC.jpeg
    C13EB7ED-5473-4295-B23D-D5B369217CBC.jpeg
    376.5 KB · Views: 24
  • 6B334D6D-7C13-4B55-90A4-A931FA2072A9.jpeg
    6B334D6D-7C13-4B55-90A4-A931FA2072A9.jpeg
    526.3 KB · Views: 21
  • FE9CE984-72A4-4478-91E3-8FFA40F6BC2D.jpeg
    FE9CE984-72A4-4478-91E3-8FFA40F6BC2D.jpeg
    535.8 KB · Views: 22
  • A9F51AB3-4E07-4660-B092-58025C23238C.jpeg
    A9F51AB3-4E07-4660-B092-58025C23238C.jpeg
    435.1 KB · Views: 31
Yep looks like it mate someone has been trying to seal something up at some stage 🙁 I'd of had to change that I couldn't of put it back the same way but its safe so hey ho, what you working on bud you never seem to post much about your day we could probably all learn a bit from you about boiler repair tips things to look out for common faults ect don't be shy 😉🤣 kop
 
Yep and whole flue system was replaced 3 elbows, stnd horizontal flue, m extension and the top flue gasket on the boiler

Plus a new condy trap as the last f&(!r had lost it

I’m off in a week so will try to put something together 👍
 
what you working on bud you never seem to post much about your day we could probably all learn a bit from you about boiler repair tips
My weeks are very similar mate, really mundane. Being the warmer weather too, I’m on landlord safety checks. I highly doubt I can teach anything as I work on primarily 2 model of boilers - Vaillant Ecotec Pro and Intergas Eco RF - most common faults I get on either - room stat too low or customer has ran out of gas, and don’t know how to reset meter/boiler.

Vaillant's suffer from mainly Diverter’s (leaking or letting by), F75’s and PCB’s.

Intergas - mostly low water pressure sensors, blocked expansion hose (dirty systems), ignition leads.

The other boilers I have worked on, but infrequently, Worcester combi’s, Baxi Neta-tec, potterton performa, potterton ultra. (All combi’s).

Currently feeling apathetic and possibly have low self esteem. I’ve forgotten a lot of basics, and just winging everything else. I’m at a stage in my life where I don’t know what to do. I bet you’re glad you asked now 😂
 
Last edited by a moderator:
My weeks are very similar mate, really mundane. Being the warmer weather too, I’m on landlord safety checks. I highly doubt I can teach anything as I work on primarily 2 model of boilers - Vaillant Ecotec Pro and Intergas Eco RF - most common faults I get on either - room stat too low or customer has ran out of gas, and don’t know how to reset meter/boiler.

Vaillant's suffer from mainly Diverter’s (leaking or letting by), F75’s and PCB’s.

Intergas - mostly low water pressure sensors, blocked expansion hose (dirty systems), ignition leads.

The other boilers I have worked on, but infrequently, Worcester combi’s, Baxi Neta-tec, potterton performa, potterton ultra. (All combi’s).

Currently feeling apathetic and possibly have low self esteem. I’ve forgotten a lot of basics, and just winging everything else. I’m at a stage in my life where I don’t know what to do. I bet you’re glad you asked now 😂
No I'm not mate it's good to get it out at least you know you have a problem but it's only you who can change that, our trade can and is a lonely one at times I often spend weeks in bathrooms with only the radio for company, I have to agree if I spend to long servicing or on breakdowns I find it quite boring and mundane getting access to properties, parking , dealing with landlords or estate agents shortage of spares stocked locally always means hassle and another visit sometimes two and often I haven't the time, but it's a valuable service and very important so you shouldn't be doubting your self worth , post some pictures of things you come across in your day don't really matter what? that way you can interact with more of us boiler problems can be tricky to diagnose especially if you don't do much of it but a picture or two of before and after a repair and what you did may help one of us on here or a younger member and you are reaching out to more members on here , now give yourself a kick up the ars- find a hobby or interest this life is it mate it's not a practice the time fly's by and it's not healthy to carry on as you are so rather than back slapping us let's see more of what you're doing ok bud . Regards Wayne aka kop
 
No I'm not mate it's good to get it out at least you know you have a problem but it's only you who can change that, our trade can and is a lonely one at times I often spend weeks in bathrooms with only the radio for company, I have to agree if I spend to long servicing or on breakdowns I find it quite boring and mundane getting access to properties, parking , dealing with landlords or estate agents shortage of spares stocked locally always means hassle and another visit sometimes two and often I haven't the time, but it's a valuable service and very important so you shouldn't be doubting your self worth , post some pictures of things you come across in your day don't really matter what? that way you can interact with more of us boiler problems can be tricky to diagnose especially if you don't do much of it but a picture or two of before and after a repair and what you did may help one of us on here or a younger member and you are reaching out to more members on here , now give yourself a kick up the ars- find a hobby or interest this life is it mate it's not a practice the time fly's by and it's not healthy to carry on as you are so rather than back slapping us let's see more of what you're doing ok bud . Regards Wayne aka kop
I'd do Boiler Servicing and Repairs, system troubleshooting all day long tbh. However most of mine are nice customers, we do very few landlords reports so that's a big bonus. There's just not enough money in them for us, with the hassle of getting access and that.

Bathroom's tbh I hate, and we've got loads of them to do. Just on a 3 weeker two man job at the minute. Then i've got another 6 to do before the year is out.
 
You get some Rubbish ones but most are fine and some you need to wear a hazmat suit and wipe your feet on the way out :D
 
That’s me done on this one can tell the x to f I’m done
 

Attachments

  • FEE8FA08-2073-4A5D-9859-37630430F63E.jpeg
    FEE8FA08-2073-4A5D-9859-37630430F63E.jpeg
    333.1 KB · Views: 26
  • 3558E205-24A2-4368-9B4E-0C754FA7BE51.jpeg
    3558E205-24A2-4368-9B4E-0C754FA7BE51.jpeg
    362.4 KB · Views: 31
  • DB36F225-9573-4C05-97CD-1C4CA2ED6F84.jpeg
    DB36F225-9573-4C05-97CD-1C4CA2ED6F84.jpeg
    673 KB · Views: 27
Do you not get fed up with all the s*** off tenants? Or is it not that bad. I find them all arseholes 😂
Totally bud pita, access , communication, often live like pigs and have no respect for the owners property 😠a nightmare throw in the supposably management agent who want to do as little as possible then FM not a great way to earn a crust 😂. Kop
 

Similar plumbing topics

  • Question
Very hard to follow your post Tina. What...
Replies
18
Views
4K
  • Question
Yes, The size of the external expansion...
Replies
17
Views
10K
No, I believe you absolutely. My own problem...
Replies
9
Views
247
  • Question
The customer had a Mira Sport they had bought...
Replies
14
Views
224
    • Like
  • Locked
Have another guy working for me but on this...
2
Replies
25
Views
5K
Back
Top