Got called to a service today boiler fitted for nearly 3 years visual there kane in the flue 89000 ppm wow my kane shut down No Mi no LPG sticker on the boiler guess what natural gas boiler running on LPG !!! ID the whole install and the guy doesn't no who fitted it ect he's lived there 10...
Hi folks,
First time playing with one of these beasts! It's been installed about 4yrs and never serviced until I took it to bits last week. Issue I faced was intermittent "flame lift" displayed.
I removed the burner to find this Ahaa! I thought, issue found so I cleaned this out and the...
Hello moderator, I just posted a thread regarding a ariston boiler and I belive that you have closed it and you must have a reason.
But I was going to reply if any good engineer are available to finish up the repair in SE8 london area.
Thanks
Hello friends,
I will try to make this proble short.
Boiler started going to lockdown and refuse to ignite, engineer replace PCB, no joy, then diagnosed that there is power to the spark generator but no spark, so new spark generator is fitted and boiler is firing ok.
The problem now is the DHW...
Evening all
went to look at the above boiler tonight which keeps cutting out with a 5 P3 error code. Hit reset and works fine for another 5-10 mins.
When I tested water was fluctuating hot and cold so I was leaning toward plate hex but I'm stuffed if I can find this 5 P3 code anywhere to...
Hope there is someone out there that can help, I am trying to find a installation/service manual for a Ariston Fast 11CFE, the owner does not have the manual and there is no data badge to be found. I have looked on the Ariston website but there are no old gas fired water heaters. If you can...
Had a look at this beautifully crafted machine earlier, igniting as should and the flame lit light pops on very briefly before running for 5 seconds, then cutting out and throwing the first ignition fail fault code.
Flame rec electrode looks ok, the lead has continuity through it. I found...
Looking for help Y'all,
Was looking at an Ariston micro genus 24 which had a fault code A05 on it which seem's one of the most common. Tried new electrode but no good so ordered new pcb. Installed this evening and fires up ok but display is not displaying temperature properly. Stuck in the old...
dunno why i bother to do repairs, spent all day trying to get the hot water working changed the plate ex checked the sensors, told by tech help there must be a blockage in the boiler so spent all afternoon with my flushing machine all to no avail , having to quote for a new unit tomoz. i dont...
Alright guys first post, go easy...
Looking to fit an external timer to an Aristo Dia after the integral timer broke, it says in the instructions that "the room stat and/or timer must be of low voltage type."
May be a stupid question but would a volt free contact clock be what they mean, as in...
Seems my boiler is leaking at the back of the heat exchanger, so I'm hoping it's just a case of replacing the seal.
Anyone have any experience with that and can offer a rough estimate of how much time it would take ?
The service manual doesn't look too bad, take the cover off remove the...
Hello,
Went to service a ariston eurocombi last night and the front panel seal that seals the chamber is totally ruined. Just phones technical to get a part code for a new seal and have been told to use heat resistant silicone!?
This does not sound right to me but, it was their technical...
I have been called out to look at this boiler which is not working it sound like igntion problem
took the combustion door off to look at the electrodes which they are looking ok then tried the boiler and is working ok on hot water and heating and put the cover back and the boiler goes to lock...
Can anyone shed some light on a possible cause when a boiler does this... Same fault found on YouTube!
Ariston EuroCombi Fault - YouTube
its a 16 year old ariston eurocombi
i went to one on Friday, exact same fault, it goes thru this sequence about 3 times then lights correctly... The boiler...
Hi All I have the above Boiler and I haven't had any Hot water since Dec 22nd 2013
Due to an Error Code E34. So I googled it and this is what I found out about the Fault.
BELOW IS A GUY WHO HAD THE SAME ERROR
I had this problem last year. Shropshire Gas came and fitted a new pcb .. costing me...
Hi all, I just been working on a ariston microgenus23 mffi combi and the problem is that it fires up and its cool and as soon as u turn on the hot tap it diverts to hot water and when you turn the tap off the boiler goes out then it go through the firing up sequence and sometimes it goes out and...
Am posting for general consensus. On the 11th of December i carried out work in a flat, while i was there they asked me to service their non condencing ariston boiler. I noticed a water mark on the ceiling along the probable flue route. Gained access to the loft. On inspection i found evidence...
Got this 10 days ago for a customer, he used it for a week then decided he wanted a bigger unit (His fault its what he wanted) Cost almost £400.00, need £250.00 to break even on job. Don't have any instructions ,customer lost them, Pick up only as this is a large item, Located 15 miles out of...
I installed an Ariston E-Combi Evo 30FF on Friday. It's been working fine until a few hours ago. As soon as hot water or heating is called for, the boiler locks out, the reset light comes on. On the display it alternates between RESET and 612. Now there isn't an error/fault code in the booklet...