Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

boiler

  1. B

    Re Condensing boiler

    Hi Just wondering if anyone can help? I moved into a new build several years back and have noticed that every time I empty dishwater into my sink the boiler (in my kitchen) makes a gurgling noise. The sink waste and the boiler overflow both run into the soil pipe! Is this anything to get...
  2. Ant0912

    Fire valve external oil boiler

    We have an external grant vortex pro and the fire valve is on the oil supply line 1.4m away from the boiler . Read somewhere should be a distance of minimum 1 metre away . The sensor end is clipped into clip above the burner correctly . Just wondered if the fire valve should be closer or if...
  3. M

    Plastic flow/return into boiler case normal?

    Hi I was viewing a house today and came across a few questionable plumbing practices. Looking at the outside oil boiler I noticed pushfit plastic flow/return going into the case and wanted to know others opinion on this? I would of thought building regulations required copper from the boiler...
  4. S

    Boiler sounds like a plane

    Can anyone advise why my Worcester Bosch System boiler when heating hot water does this sort of surging/woosh/hum that's a slightly higher pitch than the normal water heating noise noise like a plane taking off every 5 to 15 minutes? It last about 10 to 15 seconds each time. It's very noisy and...
  5. T

    Indirect (Boiler Fed) Megaflo Doesn't Stop Heating

    Hi, I noticed yesterday that when my HW is on, that the boiler runs constantly... I even tested this morning after it ran last night so no water usage overnight and it ran for 30 minutes before I turned it off on the controls. No dripping from Tundish. My suspicion is the thermostat in the...
  6. H

    Boiler filling loop

    Hi, is there anywhere you can just buy a boiler filling loop, ie without the shut off valves on the loop, already have all the connections fitted below my boiler.
  7. H

    Combi boiler problem

    Hi this is my first post so please be gentle. I have a Worcester greenstar 28i junior combi fitted in my house, we were having a troublesome drip from the back right of boiler, we found a gas safe plumber who come round and had a good look, he told me the back right hand block was leaking and...
  8. L

    Hot water issue with combi boiler

    I have a combi boiler, the hot water to my bath and taps upstairs is hot and stays hot, aswell as the hot tap in my downstairs bathroom, but in my kitchen the hot tap gets very very hot but it only lasts a couple of minutes then runs cold. I don’t know if it’s connected but the previous owner...
  9. P

    Worcester Bosch Greenstar Regular Boiler - Always ON

    Morning all, I've noticed very recently that our Worcester Bosch Boiler is constantly ON and making a fair bit of noise. The flame is not on, but certainly sounds like the pump is running, AND the water temperature does seem high considering we've not had any demand for it for a good 48hrs or...
  10. S

    Electrician Boiler Fault

    Boiler Fault I’m hoping someone can help with this boiler problem. Couple have just moved into a house that has a Grant Vortex combi boiler. The current setup is a two channel programmer, turn the heating on at programmer & it calls for heat at stat that then returns to CH terminal inside...
  11. M

    One pipe system condensing boiler.

    Would a one pipe system work efficiently on a condensing boiler as the return type would likely be below 54c all the time. So the boiler would run in condensing mode. Alot of condensing boilers don't run in condensing mode.
  12. P

    Changing from system to combi boiler with under floor pipework.

    Wondering should i change a system boiler with a combi if I have underfloor pipes in a single storey 2 bed 90s bungalow There are only 9 bungalows in the close and I was told 2 of these had leaks in floor when they changed to a combi by a neighbor. He said as he was an engineer he would not...
  13. A

    Combi Gas Boiler Intermittent Problem - Need to identify replacement part?

    Hi All, Combo Gas Boiler - Immergas Zeus Mini I’m hoping you can maybe help me with an intermittent issue I’m having with my Immergas Zeus Mini Combi Boiler. It works for weeks and then has a sporadic issue with igniting the boiler? I’ve uploaded a video so maybe you can take a Quick Look to...
  14. A

    Problem with Vaillant eco tec boiler

    My 10 year old Vaillant Eco Tec Boiler pump/fan occasionally turns on for 10 secs when the cold water supply is turned off at the tap or toilet after use. If the tap is turned off slowly, it doesn't happen. Any suggestions please?
  15. T

    Ferolli boiler leaking water from gas valve

    I have a ferolli HE31C and it has developed a water leak that appears to be from a porous casing in the gas valve. I can not see where water even enters the gas valve as I presume the gas goes in the bottom and out of the top of the valve. To check this out I dried it off and put some sealant...
  16. F

    Open vented system, No HW, CH works fine, BAXI 80HE boiler shows Dry Fire after every restart

    Hi, I have an open vented system with Cylinder and F&E tank in the loft. I have noticed for about 2 weeks now that the hot water has been gradually getting less hot and currently is only luke warm. I tried raising the termostat on the cylinder which does not seem to take any effect. I do not...
  17. S

    Firebird condensing Boiler issues help needed

    Hi there Well after my last posts, we have a new ufh manifold and return temp is good. But we still have an issues with the water being blown out the condensate trap when the boiler starts up and melting the condensate pipe. We have a .65 80s nozzle, pump pressure 12 bar, air set to 5, co2...
  18. M

    Boiler in loft draining system/ refill

    Is there any extra procedures to take when draining and re-fillling a system with the boiler in the loft. High point. Thanks?
  19. H

    Vailliant Boiler insanely hot water

    Hi I have a 5 year old Vailliant boiler and for the past few weeks the hot water has been coming out scalding hot. I have tried turning the dial down on the front of the boiler but it doesn't seem to do anything. It is so hot that even with rubber gloves on my wife says it still burns her...
  20. J

    Boiler pressure on EcoTec keeps rising

    Hi All, I have a problem with my 10 year old EcoTec boiler. The pressure keeps rising to over 3 bar every few days. To get it running again I am releasing about a cupful of water from a radiator to get it below 3 bar. The filling loop is disconnected and I’ve noticed water from the pressure...