I looked at this last week but it's more than I'm ticketed for.
Replace two Keston c55s (in tandem) with another two Keston heat 55s.
Client has got a deal from Keston so he'll supply the boilers.
John
Local branch manager is trying to sell me Vokera C30 combis, says very good boiler but full kit is £400 cheaper than Worcester or Vaillant, they offer 7 year warranty but Iv never fitted or used after sales so no idea, anyone got any answersplease
Hi , I need to quote on a replacement for an old glowworm xtrafast 96 which is a high delivery combi. I only have 470mm outside wall to mount the replacement on which rules out a vitodens 111w and a glowworm 35 which are both too wide. The vaillant 938 is only 440mm wide, can anyone recommend a...
Evening all
Hope everyone is well & have plenty of work.
Been really busy myself for as long as I can remember although I'm not complaining lol
Need everyone's thoughts on a floor standing heat only please
Been to a WB Greenstar 30 CDI regular today & it's f*&ked to be kind lol
Custard not...
https://www.vidaxl.co.uk/c/3508/water-heaters
(and similar)
Seen a lot in Europe but rarely seen in the UK.
I would have thought they would be very useful in a lot of situations.
Maybe they are not approved??
Evenong chaps boiler replacemant job ive gotta do customer has requested a stainless hex any recommendations, heat only around 15 kw, eco blue vallient or viessman , Cheers team
May be useful to some,i once had a nasty bump off a 105 that was on a 3 pin plug,it was unplugged from the wall,the washing machine turned out to be faulty and was earthing through the plumbing and everything connected to it,the 105 got away with just showing a ntc fault,since that incident i...
Decided today to hand back any Chaffoteaux Minima MX2's which come my way! For some reason that god only knows there's loads of these around my way. Dry part change no problem but anything on the hydroblock then forget it. Have killed 2/2 now and my hands with it! All I can think is they must...
A friend has an old Thorn Olympic 20/35F where the gasket on the flue has failed. Shut off by her BG service engineer after combustion analysis.
She wants a new boiler anyway due to its age and has had a couple of quotes. She was told that she could get a grant for some of the cost. Can anyone...
Morning all I am 3 weeks away from completing my gas safe training.
Wondering if anyone knows much about this government funded boiler scheme?
how do I qualify as a installer, how do I apply, is it worth it?
Hi this is my first post and I wondered if anyone would have any views on the advantages (if any) of using twin oil boilers in a very light commercial building ie the local parish church. I have been asked to look at replacing the existing 45kw electric santon water heater with a oil fired...
Can some clearly explain why a combi boiler would need a twin programmer when the hot water will always be priority over the heating.
I know that you could preheat the water so there is less time you wait for hot water to pour out of the tap. But surely that's what you expect from most combi...
Went to quote for a sister of a good customer.
They had old ariston combi in back bedroom and wanted it putting downstairs in pantry. I always thiught you couldnt do it. It had to be a new boiler as its technically a new installation.
Am i right or someone flouti g building regs as im...
Is it just me or are these boilers a pain to service and repair.
Had to replace the PRV on a Junior greenstar 28i and it was a nightmare to replace. Even testing a GV the plugs are on the back so needed to be removed to check solenoids.
Does doing their training course help at all?
Would be good...
Hi all,
Have an existing customer who have had Ideal out to look at her boiler. They have put her boiler at risk on the basis that the main volt harness has been repaired/new one needed.
What does this mean in English please? Presumably it just means the control cables running through the...
Hi All
For all you Worcester Bosch lovers out there, purchase any domestic NG or LPG Worcester boiler this weekend at www.tradeonlyplumbing.co.uk and we will throw in a FREE system filter.
Delivery is free to UK mainland for orders over £100.
Offer ends midnight on Sunday 21st Feb.