Hi everyone,
I am looking to see if anyone has purchased a bar shower where the hot is incoming from the right and cold coming from the left, really struggling to find a bar shower and riser kit to accommodate this, any advice be much appreciated thanks
Been getting large amounts of sediment coming through the electric shower.
Had two plumbers look at the job who are unsure of how the sediment can be getting through to the electric shower. The electric shower is run off the mains not from the cold water tank. Any ideas on how this has...
Vaillant ecomax 18e boiler noise at cold start.
Replaced heat exchanger with reconditioned unit and new flue collector as kettling was getting problematic. Works fine except vibrating for around 10 seconds on cold start. Didn't do it before. Any ideas?
I refer to modern purpose-built flats - built within the last 35 years, say. How common is it, in this type of accommodation, for the cold water supply to a bathroom washbasin to come indirectly through a cold water storage tank? Or is it far more common for the cold water supply to come...
Hello. I have an oil fuelled combi boiler and the hot water starts hot, then goes cold for a few seconds and then back to hot... Is this right? Thank you.
For residential housing, what are the current regulations and/or recommended/standard practices regarding the supply of cold water to the taps on kitchen sinks and bathroom washbasins? Must the supply come directly from the mains or can it come from the cold water storage tank? Or is the...
Hi all,
Hope you’re all doing well.
I had a new bathroom installed recently which involved new piping, and also capping off some redundant pipes. Since then, my boiler (pretty new Vaillant combi) turns on when I turn the cold water on. I’ve done some reading and it seems like the problem is...
Hi, I’m having issues with cold water to multiple outlets. Taps, showers, toilets cold water is fine at the kitchen sink. The hot water system is a Glenhill unvented cylinder. Hot water is fine at all outlets. I assumed the cold outlets not working were from the balanced cold from the...
I just had installed a Navien NPE-2 with built in recirculator pump. I have a dedicated return line. The check valve for the recirc is built into the unit; a spring check valve was placed on the cold line (per the manual) after which there is an expansion tank (on the cold line) in a T junction...
This is doing my head in, so I am turning to the experts here for any wisdom...
In the last couple of days I have very low cold water pressure in my downstairs utility room and downstairs bathroom (they back on to each other). The main cold feed (kitchen tap) is normal pressure. And all the...
If changing a combi boiler system to a heat pump. What do they usually do with the balanced cold connection on the hot water cylinder? Cap it. And put a pressure reducer on the mains so they have equal hot and cold pressures? I can't see them repiping a balanced cold from the cylinder to each...
Hi everyone,
Recently all the water tanks in the attic were disconnected to connect to the mains water supply (mine was already on mains but the other 5 flats in the building needed to be connected to mains water) and the company were also going to fit PRV's and isolation valves to the pipework...
I'm in a house with the cold feed coming up in the kitchen. In 25mm mdpe. The boiler is in the garage adjacent. I plan on running the cold from the sink in the kitchen under the kitchen units to the garage to feed to boiler. And the 15mm coming back from the boiler to the sink. Would there be...
I had my indirect hot water cylinder removed a few days ago and the central heating boiler and pump is turned off at the fuse spur right next to the boiler.
I have been without hot water for a few days which is fine - The plumber left the flow / return to the cylinder uncapped as well as the...
Hi,
We had a Valiant ecoTECplus 938 installed a couple of years ago. The past few months we've noticed it come on with the cold taps rather than just the hot. A plumber came to service it and said this is normal but we don't think it is + it's a waste of valuable gas. I've read up and think it...
I live in an apartment and have a cold water tank in it. The cold water tank feeds the cold water tap in the sink and the bath. Recently, I refurbished my bathroom and, according to the plumber that fitted the new taps, high-pressure taps were fitted. Consequently, the water that comes out of...
Hi,
Recently noticed an issue with thermostatic shower that was determined to get sorted. The shower would drop (which got worse) and would not maintain temperature,due to water quality here and visible limescale in cartridges,decide to just replace entire shower for a nice new one.
This...
I’m doing a bathroom refit, and there’s some strange pipework design that I’d like some advice on, please.
I want to remove the cold water pipe running through the loft space because I would rather avoid having a cold water pipe buried under the loft roll insulation.
Instead, I’d like to reuse...
Hi, I had a Madrid 2 Triton shower, I had it for 6 years then one day it started to run cold, so I purchased a Triton Seville shower and changed them over, that was running great for 3 days and now that has gone freezing cold, any advice? Thank you