connection | Page 7

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

connection

  1. G

    Gas cooker connection unusual

    Hi all. I've bought this candy gas oven second hand but unused. The problem is It won't connect with the usual gas hose to the mains. I have shown this to a relative who's a heating engineer and he hasn't seen this before. I also contacted candy and they were worse than useless. On first glance...
  2. M

    Using existing copper M10 tails for push fit connection

    Hi all Is it possible to cut existing M10 copper tails feeding existing monobloc tap at the 15mm section and then connect push fit M10 tap flexies? Reason I ask is that the original M10 copper tails are eminating from two compression 15mm isolation valves with a lot of other pipework in the...
  3. R

    Parkray multi fuel stove connection

    hi folks, I am trying to connect a new parkray multifuel stove in my living room. Problem is that having removed old burner, the joining cuff is firmly sealed to the flue. Only way to receive it will be to cut it off, thence losing a few inches of the flue length. I will them need some kind of...
  4. Carole

    Dishwasher connection

    Have just moved into a property when there is a circuit and dedicated plumbing for dishwasher. Photo in profile . Can the top of this just be removed and the water draining pipe from the dishwasher be pushed into this pipe or do I need any other fitting? There has never been a dishwasher...
  5. A

    Concealed connection - tape or thread sealant

    Hi I have a Grohe concealed shower valve I’m in installing and the casing it has 1/2 inch BSP-P female threads built into the box. Therefore I need to attach 1/2 inch BSP male to 15mm fittings to allow me to connect up the pipes. As I will be tiling over I wanted to ensure the best libg term...
  6. J

    Unusual grohe deck mixer hose connection

    Hi all Struggling to find a new hose for this unusual union on a grohe deck mixer it almost looks like a outside tap hose lock, it’s not threaded at all, just a male spigot with an o-ring. Thanks
  7. T

    Mains gas connection

    Hey guys does anyone know how much they charge to connect a house to the mains? Less than 10m Cheers
  8. MrGatch

    New Water Supply - Domestic Connection Options

    I have a new 32mm MDPE supply pipe being fitted at my property and my builder and I have been discussing how best to connect it up to the existing 22mm copper water pipe inside. There obviously needs to be a stopcock, meter adapter and drain-off valve in between the two. There doesn't seem to...
  9. K

    help gas cooker connection issue

    HI is this self sealing end. Thanks
  10. A

    Anyone recognise this shower hose connection?

    I'm new to the forum (hello). Been trying to get a replacement shower hose for ages, but can't find any that are like this. Any ideas? It's the connection on the left that I can't find anywhere. It screws into the shower unit outlet (side/hand shower) Any help would be appreciated. :)
  11. J

    FLEXI TOILET CONNECTION

    Can anybody help please. Can someone tell me if the flexi connector in the picture on the toilet fill has too tighter a bend on it i have asked my plumber if he would connect the toilet in copper because 1 I think it would look better and 2 i think it is bent so much it may fail prematurely. He...
  12. D

    Boiler & Immersion connection recommendations please.

    Hello all I have just replaced and relocated a hot water tank and immersion heater. The two were previously connected with 14mm copper and a tap on just near the outlet of each. Obviously the taps used to be opened and closed to take hot water from either the tank or the boiler. My intention...
  13. M

    Special fibre washer for gas boiler connection?

    I fit mainly ideal boilers and they come with a blue coloured fibre washer that is specified for the gas connection to the boiler. Can anyone explain why a fibre washer used on gas has to be different for the ones used on the wet system? Thanks.
  14. S

    Salus thermostat lost connection with receiver

    Hi there, I would really appreciate some help if possible. I have an Ideal Instinct boiler and a Salus RT510TX thermostat. Last night the Salus thermostat stopped connecting with the receiver- there is a red flashing light on the receiver, the heating no longer comes on and it no longer responds...
  15. A

    Slow dripping L connection under sink

    Hi, I have a leak under the sink and have found the source, that being a L shape pipe connection which is behind some plaster board. To the right of the sink there is a dishwasher and to the left there is a washing machine. The damp plasterboard is due to my genius idea of putting a rag around...
  16. R

    Baxi 105 HE heat exchanger connection question

    Hi All, I've re-fitted the primary heat exchanger on a Baxi 105 HE and there is a leak from the return pipe connection. I've tried cleaning all mating surfaces and refitting using putty but to no affect. It's a push fitting of the copper pipe into the heat exchanger and is held in with a clamp...
  17. S

    What size is this rad/valve connection? picture included

    Hi all. I'm removing the rad in the picture for decorating and want to blank off the connection from the thermostat/valve to the rad (will do both ends obviously). The thermostat/valve has 1/2 bsp stamped on it but pretty sure the connection to the rad is not 1/2 bsp, I have a couple of 1/2 bsp...
  18. Inverness

    I need oil pressure test gauge and hose connection

    I'm looking for a cheap oil pressure guage and the hose that connects to oil pump. can someone recommend on eBay for a basic gauge and hose. I can get a gauge for £15 but I don't know what hose size I need.
  19. A

    Sundial Wiring Centre Room Thermostat Connection

    I have a very old Sundial Wiring Centre box on a Y-Plan CH system. It currently does not have the room thermostat connected to it but terminal 1 and 3 in the wiring centre's room stat block are linked by a single wire as instructed in the documentation for the Sundial Wiring Centre. However...
  20. A

    Flexible Connection to Hob

    I have often read that you cannot connect a hob with a flexible connection under Gas Safe rules and regs. I was also told this by my gas fitter. Just in case you are not aware there is now a way, albeit a "semi-rigid" pipe, but to all intense and purposes it is a flexible. See Screwfix part...
Back
Top