control
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

control

  1. H

    Shower temperature control not working - goes hot and cold

    My shower temperature control isn’t working. One moment it’s freezing and the next it’s boiling. It’s a three-way shower - two shower heads the bath as well. I’ve no idea what brand if shower it is. I took the knobs off and gave them a clean but can’t figure out how to take off this middle...
  2. B

    Reliance inlet control valve 3/4.5 is overflowing

    My unvented domestic heating and hot water system incorporates a RWC CWIC 2000 3/4.5 bar pressure control which recently has begun to overflow periodically outside the house. The system is only 3 years old. I am not fully sure of the 5 RWC connections but the two regulated outlets feed the...
  3. C

    Replacing Grohe wireless shower control unit

    Hello I need to replace my Grohe Geotherm shower cubicle mounted control unit. Its around 17 years old but replacements seem to be available The main hot / cold water control unit is in the loft, I think its working ok How do I get the replacement cubicle control to connect to the loft unit...
  4. D

    OSO unvented hot water cylinder - Wi-Fi / programmable control

    Hi all, I have an OSO Direct 210 hit water cylinder installed in my home, with 2 switches (on/off; and boost). The boiler is for hot water only (rads are electric). In the 5 years that I’ve lived at this property, I’ve never once turned the boiler off; however, with soaring energy prices, I’m...
  5. ericmark

    Google Nest Central heating control how to improve?

    I have a home with an oil boiler in a garage turned into a flat, heating both flat and main house, running c plan with two pumps, two motorised valves simple bi-metal thermostat on wall in flat with 4 standard TRV's rarely used so not worried about the flat, and main house has Nest Gen 3 in the...
  6. R

    Warmflow B1 Thermostat Control

    The boiler is a Warmflow B1 Oil CH Boiler. Does the thermostat fail in an open state or closed state with a hard failure? Can they simply start to malfunction and not control the temperature correctly in a soft fail situation? The boiler is working but the homeowner says it's running all the...
  7. P

    Replacing Thermostatic cartridge -temp control housing stuck

    I'm attempting to replace an ultra SASF2 – M thermostatic shower cartridge but, having removed the temperature control knob from the housing that incorporates the temperature 'stop' mechanism, I cannot pull this housing free from the rest of the assembly. I can see no circlip holding it in...
  8. J

    GROHE smart control tap

    Hi just purchased above tap it has 19mm flexi tails and want to fit to a standard 15mm isolation valve. Is there an adapter available as isolation valve is male type, so 19mm flexi needs to screw onto standard 15mm coupling. Any advice appreciated.
  9. G

    Control System for 3 zone Central heating?

    HI folks, this post is a follow up to my post relating to my single pipe heating system. In summary, I have a house built in 1980 (I bought it 2 years ago) that had a single pipe heating system but over the years there have been some changes made to the system that meant it didn't work. I have...
  10. notsure

    Grundfos Pump Domestic, Speed control

    I'm making my own replacement for a boilermate 2000 controler. I need more electical information on the pump so I can work out how to control the speed on it. does anyone know where I can find detailed electical info for this not just "on off" it looks like the original controler used PWM to...
  11. B

    Trevi CTV volume control handle removal

    I'm removing a Trevi CTV but struggling removing the volume control handle. The temperature control knob is removed but I can't see how to remove the volume control handle. It won't budge. Does it just clip off?I Any help would be appreciated Thanks
  12. C

    Building control and LPG installation for cooking hob.

    Outside of using a gas-safe LPG engineer, do I have to notify building control for the installation of pipework, hob and a 15kg propane bottle?
  13. J

    Please Help Identify Shower Thermostatic Control Cartridge Brass Screw

    Hello, The brass "screw" that connects the shower handle to the cartridge broke. I have asked numerous plumbers and supply stores, but no one is able to identify the company, part, or model number. I thought I found the part from Rohl, but after speaking with their customer service, they said...
  14. N

    Please Help Identify Shower Thermostat Control Cartridge Brass Screw

    Hello, The brass "screw" that connects the shower handle to the cartridge broke. I have asked numerous plumbers and supply stores, but no one is able to identify the company, part, or model number. I thought I found the part from Rohl, but after speaking with their customer service, they said...
  15. J

    Heatslave 20/25 lockout not control unit or burner

    Hello!! I’ve got an old heatslave 20/25 running on kerosene. Came up with a lockout today. Tested everything I could. Symptoms, blower not starting. But… The burner runs and the boiler works if I bypass the “back to mainboard” loop for the blower motor live. To be specific, pin 4 pink wire from...
  16. D

    Is it possible to 'repair' a Hep2O (Wavin) UFH flow control?

    After balancing the flows, one of these blighters has started to drip very slowly from under the red cap. It feels loose to turn, so I suspect the seal around the spindle is to blame. It won't be 'worn' as such, as they don't get fiddled with for years, but this tiny adjustment was seemingly...
  17. E

    Setting temperature control on Heatmiser Slimline

    I have preformed a Factory Reset and re-calibrated the Thermostat. Can anyone tell me if I now Set the Temperature Control will that cover the total 24 hour period. I have tried to do this and then found the stat set at 5oC hotter - not a great idea in these cash-strapped times!!
  18. D

    Need help identifying shower control and cartridge?

    Single handle no markings any where. The seat rides on a cylinder and is concaved or valley shaped instead of flat. Been too every pro plumbing supply store and box store in town no help.
  19. M

    Will Building Control permit a combined rainwater / sewage system?

    Our Victorian house's rainwater down-pipes are connected to the foul-water sewer. In order to accomodate new wider French windows I want to move the existing soil stack. When they see the plans or site do you think Building Control will want to alter the existing rainwater arrangements? All the...
  20. I

    Honeywell Evohome hot water control for new boiler

    Looking for a quick bit of advice since I'm trying to wrap my head around what work I need done. Right now I have an old conventional boiler that heats my hot water tank. The water tank has manual open/shut valve so that I can only heat the water tank and not the heating. I'm replacing this...
Back
Top