Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

control

  1. N

    Control book

    https://www.dropbox.com/s/92mcdar7eprd79l/domestic%20Central%20heating%20controls.pdf?dl=0
  2. G

    Control panels

    Can anyone recomend some good reading material regarding the above had a fault today that took way longer to solve then it should have. Not looking for anything too in depth just basic functional flow typical system set up and the operation of components. Just to get me familiar with it all...
  3. G

    Help needed, unable to control rads temperature

    Hi everyone. Im new to this forum and seeking advise please. I have an old (22 years) vented 10 rad system. The pump started to run very noisy following the system being drained down to remove bathroom rad during a refurbishment. After several investigations by a plumber the valve in the cold...
  4. W

    Can you only thermostatically control a mixer tap?

    As opposed to an individual single hot tap? Never installed TMV's before. Customer has basin with two separate basin taps. Wants hot at set child friendly temp. Thanks.
  5. G

    Replacing central heating control unit

    Hi all, this is my first post. My gas central heating control unit (potterton ep2 twin channel programmer) has switched off. I've taken it off, tried replacing the battery, hit it a few times, with no luck. Is the back plate a universal plate? Can I just buy a new unit and attach it to that...
  6. S

    Remote heating control

    Hey guys Just after if any one has come across this before. I'm after some thing where I can turn the heating on say if I'm on the way home from work etc
  7. D

    Honeywell control panel flashing constantly

    Hi there, I'm new to this site and cannot find the answer I need through other posts. My honeywell st9100c control panel for the CH keeps flashing when I put it to continuous for the heating and the heating doesn't come on. All radiators have heen bled and I've increased the pressure on my...
  8. C

    new unvented tank should the plumber notify building control?

    had a unvented hw tank fitted. should the plumber have notified building control? if so how can I check?
  9. W

    Installing Cold Water Storage Cisterns and Building Control?

    Hi there, Does anyone know if the local Building Control has to be informed when replacing a Cold Water Storage Cistern and F&E tank? I know they need to know when replacing a cylinder, just not sure about storage tanks. Thanks in advance Mike :-)
  10. B

    Mis-aligned control dials on thermostatic shower kit

    Hello after installing a 2 way thermotstic shower kit i have noticed that the temp control dial in the middle has to be turned slightly to the right to be in the neutral (clicked) position and the bottom one which controls the hand held part has to be turned a bit to the left to actually turn...
  11. S

    Gas pipe and boiler control switch searation distance

    What are people's interpretation of the above? Example: Gas pipe running surface up to the boiler and fused switch for the boiler. Regs state meters, fuseboxes and SWITCHGEAR to be 150mm apart. Would you class a boiler fuse spur (not socket) as switchgear (similar to a light switch).
  12. A

    What model is this shower mixer/control anyone? Thanks

  13. F

    Wanted: Mira Platinum Dual Pumped Control Box

    Hi I am in need of the above must be pumped version. Have you got one sat around after a move to a pressurised system? Thanks, Nick
  14. D

    How to install a RAVI or Tapstat to control HW cylinder water temperature.

    Hi All, New to the forum and only have basic plumbing knowledge so here goes on my first post. I currently have no temp control on my HW cylinder and was thinking of installing a RAVI or Tapstat type mechanical thermostatic control valve.At the moment,HW cylinder temp is being crudely...
  15. S

    Worcester Heatslave 2 CH control

    I have a brand new Worcester Heatslave 2 oil boiler complete with a wireless DT10RF controller fitted. The feed to the existing CH system is via a 2 port motorized valve. A new UFH heating system is being installed with a single two port motorised valve on the hot feed to the manifold and a pump...
  16. W

    Ebola 'out of control' in West Africa

    http://www.telegraph.co.uk/news/worldnews/africaandindianocean/guinea/10942598/Ebola-out-of-control-in-West-Africa-as-health-workers-rush-to-trace-1500-possible-victims.html
  17. N

    How to control second pump from Worcester Greenstart boiler?

    I've got a Worcester Greenstar 18i System boiler with integrated pump. The optional DT10RF controller has been installed. The boiler is used only for central heating. I've also got a Wilo pump with three-way blender mixer connected to the underfloor hydronic pipes. The three-way keeps the...
  18. X

    No hot water after turn off heating setting on control panel. HELP pls!

    I live in a two stories home. Covert boiler (Potterton Suprima boiler ) locates in ground floor, cylinder in 1st floor and there's a pump in loft between ground and 1st floor. 5 days ago, I turned off the heating setting on control panel next to the boiler to save some gas in the summer and...