  1. J

    Why would cold mains feeding the boiler need an expansion vessel?

    British gas fixed a leak in the boiler and said the due to the recently installed water meter the fluxuation in pressure caused the leak. They advised to get a expansion vessel on the the cold mains entering the boiler. I read on here someone say that Worcester wouldn't warranty boilers being...
  2. Lumen

    Lowering Expansion Vessels on Unvented System

    Hi Chaps, Wife has been nagging me about having shelves in an airing cupboard for about a year now. We've had unvented cylinder fitted last year and both expansion vessels are very high to fit a towel shelve (as it will be just below the top of door frame). Can the expansion vessels be lowered...
  3. Jock Spanners

    Where's the best place to site a heating expansion vessel?

    Evening all, I'm converting a regular boiler to a sealed system and unvented cylinder. The Megaflow is in the bathroom and the boiler downstairs high on a wall. I'm running the cylinder vent to the soil stack. I'm struggling to decide where to put the expansion vessel on the heating. It's an s...
  4. N

    Wilo pump & expansion tank - need to repressurise

    I live in Azerbaijan where I have a Wilo MC605-EM pump attached to a Wilo LRS 50/10H diaphragm expansion vessel, which pumps water into my house on demand. We have a large water storage tank sitting between the mains and the pump so there is effectively no water pressure, the pump sucks water...
  5. N

    Best solution for a failed expansion vessel?

    I have a Vaillant Turbomax Plus boiler, fitted in 2005. Recently it's locked out several times due to low pressure, which prompted me to check the expansion vessel. When I pressed the Schrader valve I found that water, rather than air, was released. That suggests to me a failure of the...
  6. J

    Repressurise white expansion vessel

    Hi all, I've got my G3 card. First time I've attempted to re-pressurise the white, expansion vessel above an unvented cylinder. I first turned the water off, ran the taps to relieve the pressure. The vessel (it was flat). I managed to pump it up to 1.2bar with no issues. But then it was...
  7. B

    Expansion Tank Tap/Valve

    This tap sits below my Potterton Combi Expansion Tank, I think its the cold water inlet valve Should the tap be ON or OFF To me is looks currently in the ON position
  8. B

    URGENT water level changes significantly in expansion pipe (open vented system)

    I have made some adaptations to the layout of an existing open vented one pipe system. The pump is now some 6 or 7 metres away from the boiler. The cold feed is on the negative side of the pump as is the expansion pipe. The order of fixing is expansion pipe - cold feed - pump. When the pump...
  9. F

    Best CH expansion vessel

    Hello again from enthusiastic amateur. Previous request for help re daughter's pressure reducing Ideal boiler helped me to get it sorted economically. Today my query is re my own system with Worcester Bosch system boiler where I think the built in expansion vessel is inadequate or faulty. I...
  10. H

    Kerosene Boiler Worcester 12/18 Heatslave "hot water expansion" !

    This heating system is new to me, in reality about 8 years old and in good condition. In the tail end of last winter's heating season, I think I shot myself in the foot. With more bedrooms than occupants and a water cost of about £4/tonne, I had a water meter installed. It might have been a...
  11. G

    Expansion Tank Issues

    Every time I flush my toilets, I hear a popping sound from my expansion tank. I have drained the water from my electric hot water heater. I have shut off all the water going into the house, cut my faucets on to drain them to get any air out my lines. Im going nuts trying to figure this out...
  12. tonyt

    Vented system - Expansion / fill pipe or pipes?

    Hi, I'm coming to the brainy forum for a proper answer! Scene - vented system, was originally gravity with Aga, then oil boiler with integral pump, then new oil boiler last year with fully pumped "Y" system. I have problems with air in radiators. I find there is a single 22mm expansion/fill...
  13. A

    Expansion vessel

    If there is an unvented cylinder being installed in the loft, System boiler downstairs, how would you decide what size expansion vessel to put on the heating side and how will you configure the Pipework for heating expansion vessel in the loft. As there will be an expansion vessel in the boiler...
  14. I

    Expansion Vessel Vibration

    First post after a lot of browsing and hoping for some insight into an on-going issue. I have a Glenhill unvented cylinder setup on my house. Installed 5 years ago (I’ve lived here for a year). Backstory: The expansion vessel was replaced in November as the last one had started to leak. No...
  15. J

    European / international water heaters, no expansion vessel

    I've seen and heard about this a couple of times. When installing an un-vented water heater some parts of the world seem to fit an expansion valve and just allow it to blow off each time the water is heated. No expansion vessel is fitted on the incoming pipe work, they either fit it to a...
  16. Riley

    Exploded expansion vessel

    From the start I will say this is not installed by me. I was called out last night where an expansion vessel on an unvented cylinder has rusted through and gone pop. Serious flooding etc. Went over and made safe and I’m now trying to source replacement parts. I note that rather than using...
  17. 999

    Accumulator or expansion Vessal

    Hi All Ive been looking at accumulators online and ended up buying a Reflex potable water expansion vessal. I orginally googled for potable water accumulators and had a load of pages open and purchsed what might be the wrong item. Can someone confirm an expansion vessal is not the same as a...
  18. M

    Expansion vessel change on a viessmann 200wv

    hi guys. I’m after some advice on replacing a viessmann expansion vessel if anyone has any? I’ve never worked on one or installed one. I don’t normally do part replacements at all if I’m honest so any help would be appreciated please. Cheers
  19. Wetbandit

    Does this expansion vessel need supporting?

    Just noticed this on a job and wondered how dangerous it is if any of you knowledgeable people can tell me if it's supposed to be supported? Cheers wet bandit
  20. R

    Expansion Vessel Combined Boiler

    Got a weird one, no water on on valve and tested integrity using LDF and all fine. Drained down system and left drain off open and pumped to around 1 bar. It’s not holding any pressure but not showing any other of the normal symptoms of a broken membrane. My thoughts are vessel but I’m not...