fault | Page 3

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

fault

  1. L

    Advice on fault finding courses

    Hi, I currently work on new builds with very limited work on the repair, maintenance and fault finding side of boilers. I’m currently renewing my ccn1 and cenwat gas card as I type this and it has made me very interested in getting into this line of work or even have a better understanding of...
  2. T

    Drayton MA1 mid position actuator intermittent fault.

    Can anyone advise what could be the cause and how to overcome an actuator intermittently not responding when boiler is calling for heat. Possibly slightly loose fitting to valve, as actuator re-activates with hand pressure movement when boiler is calling for heat. This is an intermittent fault...
  3. moonlight

    Worcester Bosch Fault code P3

    A customer rang this morning, says they have a intermittent fault on the boiler P3. Its a Worcester CDI30 I think from a past visit. I did quote for a new boiler 10 months ago, but the old one is still hanging in there. I looked on line as I don't have the book with me. Any suggestions? He says...
  4. seanadams121

    Ferroli f34 fault for my sins

    Hi. Does anyone know the cause and solution to the f34 fault on a ferroli? The manual is saying its the low voltage error and to check the supply. Im assuming that its correct as installed and this is a pcb fault. Has anyone had any experience with this fault before i go out tomo? Cheers lads
  5. M

    Electrical fault finding?

    Hi guys. I’m still very new to boiler fault finding but was wondering whether you could advise me on a particular multimeter or tester that would help with fault finding? The wife has been a good one and got me a Martindale ET5 open jaw tester but I’m unsure whether they’re any good? I can’t...
  6. king of pipes

    Ideal icos 24 HE boiler fault

    Dodgy one today chaps this could of been very dangerous the boiler still runs with s hole in it .
  7. D

    F75 fault with Vaillant when pressure is okay

    Can someone help me understand what could be causing this fault? It only seems to happen when the pressure in the boiler drops below around 1.5 - 1.7 bars otherwise it works fine. The boiler is a Valiant Eco fit pure 835 and the building is a 3 storey house with 10 radiators. Thanks
  8. N

    Honeywell ST699 switching fault

    Honetwell St699, will switch on in once mode at desired time but won't switch off at desired time will just continue, any ideas would help greatly
  9. D

    URGENT duo-tec 28 fault code e168 new PCB

    Duo-tec 28 fault code e168 PCB replaced PCB turned boiler on same fault code e168 could it be a faulty new PCB or am I missing something
  10. B

    New Grundfos UPS3 15-50/65 130 Circulator pump fitted no heating and hot water - FD Fault code

    I have a 5 year old Ideal Logic 15 boiler that has been working alongside an old Grundfos pump possibly about 10years old. The boiler was recently (about 3 weeks ago) repaired and services by an Ideal technician. I had a plumber yesterday from Local Heros who came to fit a new Grundfos UPS3...
  11. T

    My double flush toilet has developed a fault. It won't stop filling eve when I pull the float arm right up. I have replaced the inlet valve diaphragm

    My double flush toilet has developed a fault. It won't stop filling eve when I pull the float arm right up. I have replaced the inlet valve diaphragm but this has made no difference What else can i try?
  12. L

    Vaillant ecotec 831 F61 fault

    Just wondered if anybody could help me with this one....... or advise... Called out to an ecotec 831. fault code F61. The gas valve had been changed by a third party a week before... I checked the ignition electrodes and they were caked in sh*t. Cleaned and fired back up. Advised...
  13. moonlight

    Worcester boiler with F0 fault

    I just had a call from a new customer, the boiler a Worcester 32cdi boiler is not working, hot water or heating. He told me it has an F0 fault. I looked at the manual in the office and it suggests a internal fault. He said the boiler blew the trip switch. I am going to the property on Wednesday...
  14. L

    Boiler fault F 20

    Hi everyone, I have problem with my boiler HEAT LINE CAPRIZ PLUS 28 I have error code on screen F 20 In manual instructions is F 20 : Overheating fault , Overheating safety device activated (97°C) What I should to do ? Lukas, Hemel Hempstead
  15. B

    Combination valve fault issue low pressure

    Have a combination valve with 6.5bar incoming pressure. The valve would have been set at 3 bar presumably, but the property is having lower than normal water pressure from the outlets and operating a second outlet dramatically affects the first outlet. Once the issue was noticed the static...
  16. P

    Keston C55 Fault code E36

    Hi Guys, I have been called out to a Keston C55 boiler that had a E36 Fault code, changer the flow and return thermistor but still getting E36 code? have checked all connections and wires. Any ideas. Thanks
  17. gingalig

    Gloworm 30cxi, f1 fault

    Hi all, I attended a gloworm 30cxi running on lpg today. Changed the return pipe on the heat exchanger as the rubber connector had gone hard and was leaking all over the place. Boiler fired up ran for 20 secs on dhw then fan increased speed and it went out. Went through the ignition sequence a...
  18. N

    URGENT Vaillant F23 fault Christchurch, Dorset

    My boiler has tripped out showing F23, British Gas came out two weeks ago cleaned out the pump and it worked but now has tripped out again. I need someone who can give the system a power flush. It is an open system with a hot water tank. Many Thanks in Christchurch BH23 4ER
  19. H

    Called out to fault on Alpha HE 33. New Fan Installed.

    Hi guys. First post on here. Called out to fault on Alpha HE 33. Fast blow fuse found to have blown. Faulty fan found to be problem. New fan installed and tested. Four days later and a call from customer to say boiler not working again. fast blow fuse found to have gone again. Replaced and gone...
  20. S

    10 year old Bosch Greenstar Junior water sloshing noise, then fault

    I noticed the boiler making some strange noises last night. It made the same noise previously during a severe winter several years ago when the condensate exhaust which runs into a sink waste outside froze. I checked the brass spiral filter and purged it and quite a lot of brown debris powder...