Hi new to this forum any help available would be appreciated, have got a domicondense ferroli f28 combi boiler that has been throwing a f05 and a15 fault which shuts the boiler down,have got a service plan which they replaced an air pressure switch and was told primary exchanger slightly scaled...
Hi all,
Im hoping someone can help me out as this problem is driving me crazy!
Me, the missus and our 4 month old daughter moved into a new flat recently which has a Ferroli T-ONE 30c HE boiler and it sucks..
The problem is when it is switched on it has both central heating and hot...
Davey Roberts
Thread
boiler
central
central heating
combi
combi boiler
ferroli
heating
hello all,
i have fitted a sallus room thermometer to my ferolli optimax combi bolier.
it all seemed fairly straightforward apart from one thing, the wiring plugs.
i removed the old wiring plugs from the clock and noticed it was numbered 1, 2, 3, 5
on putting in the boiler control module i...
Hi All,
This is my first post to the forum - brought on by a lack of central heating....!!
We have a Ferroli Modena 80E which has been fine until recently.
Central heating water pressure had been dropping recently. We'd top it up a bit, back to about 1 bar. That'd be fine for a day...
I'm in need of a engineer that covers ferroli boilers, have had engineer fix new sensor and Venturi, but still having problems. It worked for 10 hours, now
the system starts for 10 secs then Shuts down and low pressure light flashes, both central heating and hot water does the same, so need...
Hi any help would be appreciated, not been to look yet just posting for heads up. C
Customer has said the HW is very poor. is there anything these things are commonly know for failing on the HW side of things.
I know to check Diverter & NTC
I've fitted a best to a ferroli optimax and it won't turn off! I've spoken to ferroli and said that I have installed in onto the voltage free and he said yes that's right. He then said to add a link in but that has done nothing!
Any ideas?
Hi,
Can anyone give me a few of their opinions on what they think of the Ferroli Sigma 40-60 boiler. I have one installed that is fitted downstairs in an out build at the back of my property. The property is 2 terraced houses knocked into one and the boiler has to heat up 7 rads but only 1...
Hi Folks
Guess many of you have your own view on Ferroli s and the fact City Plumbing and many others have stopped dealing with them. Company turnover (2009 - 27.5m) (2013 - £9.7m).
Got drawn into buying a replacement for the first one by 5 year warranty on the Optimax. Called them out...
My brothers just moved in to his house which has been unoccupied for around 2 years.
Ferroli Optimax He Plus 31C at the property, so he asked if I could go and check it out as it hasn't been used for so long.
Emissions were miles out and it was making all sorts of noises, so set them up and...
Does anyone know if there is a seal kit available for this boiler?
I went to sort a leak on the boiler, just replaced the fibre washer in the return iso, but when tightening, the male part of the thread started turning inside the pump. I took it out and there's quite a thick o ring sealing it...
Hi All
My old faithfull Ferroli has finally given up on me.
The pilot ignites fine, it calls for heating/HW BUT will not ignite main burner as the air pressure switch is not operating.
The pressure switch itself is fine as i have applied very slight pressure to the intake side that...
Hi All
I have no DHW or CH from my Ferroli 701 combi boiler.
The fan is running fine, ihave looked at the led status for faults and it gives nothing.
The CH boiler pressure switch is working fine.
The pilot light ignites fine and stays lit so Thermocouple is ok.
The Overheat...
Good evening folks, We have a Ferroli Modena 80e boiler in our house and I am looking for some advice and also a good ferroli engineer local to Birmingham. We have been in...
Good Evening
I've got a problem with a boiler, it has air in the heating system and keeps shutting down.
It gives a fault code of F43 I've tried everything to get the air out but nothing will shift it or I'm doing something wrong.
It's meant to have an automatic air vent but this doesn't...
Hi,
I have the above boiler which is around 4 years old. Recently it has started giving me a number of problems and unsure if they are all related.
I now have these problems:
1. Despite the heating regulating dial being on very low the water is scalding out of the tap. However on...
Hi, I have a Ferroli HE 31C boiler and it keeps returning the error code F37 (which according to the manual, is for low water pressure) after switch on even though I had already topped up the pressure from 1.4bars, .1 bar at a time all the way until 2.5bars now.
Furthermore, I had tried to...
My Ferroli DOMIcompact boiler loses water through the condensing pipe at the rate of three quarters of a pint every five minutes. This turns the boiler off, it then will work again if the water is topped up.
When the plumber arrives, will he know what the problem is with this particular boiler?