fire | Page 2

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

fire

  1. L

    Any Help Appreciated To Identify This Gas Fire

    Hi All, I am new to the forum and am looking for any assistance to identify the gas fire in the photo's. Unfortunately the data plate is not present and we have no manual so unable to obtain a CP12 certificate. Can anyone advise what make/ model it is or point us in the direction of a...
  2. A

    Control box 569 Riello Thermital Burner fails to fire

    Why does the Control Box 569 for riello thermital supereffe 25 not fire?
  3. R

    Is my gas fire local isolation on the Restrictor?

    Hello Plumbers. We had a gas fire fitted, one of those that looks like a log burner. I need to take it out to paint the wall behind. It has a restrictor valve under it but no isolating valve that I can see. Is the restrictor an isolator as well? Should there be a separate isolating valve? Is it...
  4. wateece

    Worsted Bosch Green Star 24i won't fire

    Evening We have a Worcester Bosch Green Star 24i that keeps cycling on start up, makes some strange noises the inhibition light turns off and then it starts again until eventually lockout and reset. Reset does nothing but restart the process. Pressure is above 1 bar and in the green. It's been...
  5. J

    Gas fire with external gas pipe

    Hi all, My customer has a gas fire with an external gas pipe (runs across the front of the fire - see pic). He'd like a new gas fire. No chance of re-running the pipe through the chimney opening. Any ideas of a gas fire that would suit? I've looked at a few, but would like the gas connections...
  6. L

    Gas Fire manual needed

    Hi All, we are wanting to download a manual for a gas fire at a house recently purchased. It has been serviced & all ok, but we would like a manual if needed in the future. Attached are photos of the two plates on the fire. Thanks in advance
  7. W

    Annoying Gas Fire Problem

    Hi, I have a Kohlangaz Gosford HE gas fire. It has recently been serviced but when it is set to it's lowest heat output setting using the Remote control the heat output now seems excessive compared to that which we have become used to since it was installed in 2017. I contacted the firm who...
  8. C

    Problem with Valor Ultimate Turbochim Side Flue Fire 517SF

    I have a Turbochim side flue fire, installed Dec 2000 and has worked well for 20 years. It would not turn On the other day. Normally you press and hold On button and the fan starts. Now when you press the ON button you here a click and the fan fails to start. The fan has been tested ( Hereford...
  9. Robert Tyrrell

    URGENT Grant Combi 70 MK2 won't fire

    I've fitted a completely new burner to a Grant Combi 70 and the motor will not run (so consequently the burner won't fire) despite there being live 230v power to the control box. I have read the wiring diagrams and even spoken to Grant themselves but I cannot get to the bottom of the problem so...
  10. C

    Replacement of Baxi Bermuda C5 fire

    Hi there I have a Baxi Bermuda C5 fire with back boiler and want to replace the gas fire only with a more modern one but leave the back boiler in place, what are my options please? Regards
  11. J

    Remote controlled gas fire

    Evening Changed a guys boiler yesterday. All went ok. Today he has called and says his gas fire which is a verine dtx500 is making a loud clicking noise and not lighting. I told him to turn main fuse board switch off then on again which stopped the noise. When he tried to light it again it...
  12. D

    Oil feed pipe fire valve(s)

    Hy all, Do oftec regs allow passing of the oil feed through the foundation wall under floor space if the feed pipe is installed in a fire proof steel tube? I wondered if it would help me overcome an installation problem perhaps with a fire valve at either end of the feed as it enters and exits...
  13. B

    When my oil heating is on should it heat the water in my back boiler of open fire as well?

    When my oil heating is on should it be heating the water in my back boiler of open fire as well?
  14. G

    Cannon gas fire Melody FDRN*G

    Hello...The on off slider arm on my Cannon Melody model FDRN5*G has broken. Can anyone suggest where I can get spares here in the UK ? Thanks Grae
  15. M

    Vented, combination oil boiler/open fire multifuel boiler heating system. Air lock ?

    Hello there. . . I have a vented heating system, on an oil boiler. Also connected to the system is an open multifuel fire boiler which can be used with the oil boiler or on its own. Both will heat the radiators and the hot water. . . I recently drained down the system to change a radiator (a...
  16. J

    Gas fire not fixed to wall????

    Hi all, I'm puzzling over a gas fire Valor Homeflame. (I've fixed/serviced quite a few gas fires over the last five years, but am still learning). Every gas fire I've so far come across has been fixed securely to the closure plate/back wall, so it can't be accidentally pulled out forwards...
  17. M

    Capping pipe to gas fire/purging.

    If capping a feed to a gas fire in 15mm do you tend to use compression or solderd caps. I know comp. Is OK if accessible. But I prefer solderd caps. But does purging become an issue with solderd caps?
  18. L

    Fire valve external oil boiler

    Bit of help on the regulations please? An external oil boiler (metal case) sited outside the house but contained in a slightly larger wooden enclosure (foot bigger in all directions, ie not a shed). Would it be acceptable to place the fire valve inside the wooden enclosure?
  19. B

    Vaillant EcoTec 630 - will only partially fire and won't heads the rads

    Morning all, I'm new and shiny here and seem to have developed a heating problem this morning. Any pointers for a quick resolution would be appreciated as my ears are now hurting! :rolleyes: I have a Vaillant Ecotec Plus 630 driving rads, hot water and underfloor heating in some of the house...
  20. J

    Gas fire vermiculite replacement

    I have an old gas fire which wasn't working well. I asked a plumber to do a CP12 test (£40 as an addition to the boiler test) and tell me what he thought was required. After doing this he said it needed servicing, which would be an additional £60, and then would probably be OK. I went ahead with...