Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

floor

  1. S

    Bringing pipework through ensuite floor

    When bringing pipework through the floor of the ensuite, I wonder just how tight I need to make the fit between the floor and the pipework? I have seen a previous comment about getting the fit as tight as possible, but I’m not sure why that is necessary? Reason I ask is that it will be a PITA...
  2. T

    Under floor heating system issue

    Hi. Hoping for some advice. Yesterday I did have an authorised tech round whom fitted a new control board and electrode/cable and my DUO TEC Compact+ 24 GA came back to life but things are not going as expected and unfortunately I am in Lithuania full time since lockdown and do not speak...
  3. W

    I have a cracked 1.5" pipe elbow going into a 4" main drain under basement floor. How do I fix this?

    Hey guys My wife noticed water on the floor in our basement. What I can see is that the elbow is cracked where a 1.5" down pipe enters a 4" pipe that goes beneath the basement concrete floor. My thought is that I have to break up some concrete to replace the 4" pipe/clean out and reattached...
  4. A

    Ground floor toilet waste location

    Busy rebuilding an old bathroom in an old cottage. Bathroom is downstairs and on removing the toilet I can see it goes straight into the ground (see photo). We did want to site the loo about 3ft to the right but cannot for the an extension to the pipe through the cabinets. I could box off the...
  5. R

    How do I top up the water in the radiators on an Ideal Mexico super 2 floor boiler?

    I am needing to bleed the radiators at the church building and I opened up the boiler cupboard to see if there are any cock valves to refill the system, but can't locate any. I haven't been able to locate a pressure gauge either and it appears that this boiler doe not have a loft tank either...
  6. A

    Under Floor Heating - one of the valves sticking?

    Hi - I'm not sure what these things in the picture are called, but water flows to each room when the "float" moves down, but one is stuck. Last year a heating engineer came and unstuck the valve by tapping on it with his screwdriver head. I've tried that, but no luck - three of the floats move...
  7. J

    new bathroom fitted bath draining out via shower and floor

    just had new bathroom fitted ..taken 8 weeks ..so far! Bath is emptying via shower and all over the whole bathroom floor. Fitter says must be my drains. He is speaking of attempting to get under floor in next door airing cupboard which houses the gas boiler and try to put a vent pipe into the...
  8. A

    Sewage smells in bathroom of 2nd (top) floor flat in Leeds, UK

    We have various smells - usually sewage - coming from our bathroom occasionally. Sometimes every day then nothing for a week or two. It's a second/top floor flat and the smells come from the main bathroom wihch shares the soil pipe with floors below. We have checked all of the traps (sink, bath...
  9. R

    Ground floor flat - intermittent sewer smell

    Hi All, I live in a ground floor flat and sometimes when the back door is open get a sewer smell come into the hallway. It's very intermittent and only happens when the upstairs flat is running water. There's two drains from upstairs, one from the kitchen and then one from the bathroom which is...
  10. N

    Different flow rates on ground floor

    Hi, I've bought a four bed house, it's about 20 years old and has an adjacent garage. It has a downstairs toilet, utility room and kitchen and upstairs there's a main bathroom and an ensuite shower room. It has a vented system with boiler in garage heating cylinder on landing and a 40 gallon...
  11. P

    shower leak on floor

    Any ideas what i can do to fix this without tearing out the shower? shower drain never backs up, but pipe below it does leak below shower floor and only when taking shower. See pics. The drain must be leaking. It gets wet inside that wall and with long showers, it leaks out onto the finished...
  12. king of pipes

    Buffalo board Floor protection

    This product is a good option for protection of shower trays and flooring comes on a large roll so will do multiple jobs, picked it up in the crown decorating centre may help you out chaps if your needing to protect easily damaged surfaces . Cheers kop
  13. C

    Half of drains cause floor drain in basement to overflow

    We most likely have a clog problem that we can't seem to resolve. These are the details: The drain has been slow in the tub in bathroom #1 (located on the east end of the basement of our ranch home) for a while, but it was always keeping up pretty close and finished draining within 30 seconds...
  14. D

    Hot water boiler for floor heat bleeder valve question

    have a hot water boiler (was converted to steam before me). Want to run the oxygen Barrier pex under the bathroom floors for heat. Do these loops need a bleeder valve? Thanks
  15. J

    Indirect Drainage Problem (without getting thru the floor)

    Hello all! glad to be here.... gonna be doing quite some plumbing work with a handyman of mine to lower cost of my new business so I hope this is the right place to get some good pro info! So with my new biz, they are requiring a 3 basin sink like a restaurant kitchen, and with this they...
  16. M

    Need help with a garage floor drain cover

    Does anyone have any suggestions on where to find a replacement cast iron garage floor drain cover. Mine is severely rusted through. The diameter of the opening is 13 inches and the depth for the legs is 3 inches. I have attached some pictures of the old cover. I have tried home depot and...
  17. G

    leaky pipe under floor

    Hi, Ive hot a lot of standing water under my floorboards. I cant get access right underneath, but can guess at it being a certain speedfit pipe as I can hear dripping from a certain area. its not protected in anything, Im wondering if theres an easy way of attaching a new pipe and pulling ot...
  18. S

    Hair line crack in soil pipe under floor.

    Hey. So I’m after the best way too repair this. So here’s the set up. soil pipe internal drops down a boxing into a black connector at ground level right at floor boards which then drops into this orange pipe.The void under the floor is maybe enough I could lay down in there then this drop is...
  19. S

    Black Specks in Water (only on 2nd floor)

    I'm getting black specks in my water when running hot water, but it is only on my second floor. We have well water with a salt water softener. The specks are more oil-like and smear if I press my finger on them. The specks come out when I run the hot water (hotter the water = more specks). It...
  20. O

    In Floor Heating Issue...

    Hi all, have a condo with in floor radiant heating. The system doesn't seem to be working properly as the condo won't warm up, floor doesn't feel warm. The water unit seems to have power. Of course there are valves all over the place on this, and lots of levers to shut water flow on and off...