  1. A

    problem with water flow in a new mixer tap

    Had a new bathroom fitter, and the sink has these taps on Ideal Standard Tesi 1 lever Chrome effect Deck Mono Mixer Tap. The hot and cold water flow is reduced. But when the fitter took the taps off the water flow was increased, Could there be a problem with the new taps or is this because they...
  2. A

    Pipe size length bends junctions to Combi - affect on water flow rate?

    Hello! Advice required, please. Trying to understand implications of pipe size, length of run, and number of junctions etc. en route between the incoming water feed to the Combi-boiler. For various reasons it is difficult to get from stopcock to boiler without taking indirect route back across...
  3. C

    Poor flow of hot water in bath

    The hot & cold pipes to my bath are 15mm, shouldn't they be 21mm. The hot water is feed from a hot water tank and is a dribble whilst the cold is very strong. Should I have the pipes changed to 21mm or would an electric pump on the hot water feed suffice? If fitting a pump, are they robust and...
  4. F

    Pipe sizing - Replacing a one pipe system with flow and return

    Hi, I'm a first time poster with a skill set akin to that of a competent DIY'er I guess. I'm planning on replacing a old in efficient one pipe system with a flow and return. This will be done on our recently purchased bungalow which has an oil fired boiler. Whilst I'm confident a 22mm flow and...
  5. M

    Changing type of shower flow rate valve

    I have had the following thermostatic shower installed: Moods Round Shower https://www.homesupply.co.uk/Moods-Round-Shower-Pack-2-with-Two-Outlet-Valve-and-Rigid-Riser-Shower-Kit-DICMP0036 The flow rate control on this shower is full on or off. Would it be possible to change this valve to...
  6. M

    Changing flow rate valve

    I have this shower installed: https://www.homesupply.co.uk/Moods-Round-Shower-Pack-2-with-Two-Outlet-Valve-and-Rigid-Riser-Shower-Kit-DICMP0036 The temperature control is variable, but the flow rate control is either full on or off. Would it be possible to replace valve to a variable one? Thanks
  7. B

    Ideal Vogue S32 Gen2 occasional ‘NO WATER FLOW FAULT’

    Hi, Following an Anglia Water complete loss of Water Supply in Milton Keynes, I had a call from a Tenant reporting the No Water Flow Fault On the Ideal S32 Gen2. When I arrived at the property I found the pressure in the System Loop was absolute zero. There were boiler manual papers out in the...
  8. W

    Do NRV's reduce flow on gravity and/or need minimum pressure to work?

    Fitted a mixer tap and the mains forces it's way back up gravity hot. But the hot pressure is already very poor due to it being a flat with a combination cylinder on the same floor level as the tap. Carefully chose one that looked fairly modern (as customer wanted) but had good flow on low...
  9. B

    Arrow flow of water on valve query

    Hi everyone, I have a question about what happens when the incoming mains water valve with the arrow on it has water flowing backwards rather than forwards. For example the arrow on the water stop valve is pointing left but the water coming in is going right instead of left, would this pose as...
  10. M

    Which is flow/return

    So bit of an odd one right. I have 2 pipes, to the rad a flow/return. I cut the flow/return and capped the flow. I went to fill up the system, the water start to leak out the return. Is that normal? Is the return really the flow?
  11. brazilianx

    Flow Noise > Can't believe taps should be this noisy!

    Hi. First time poster. I've just had a new bathroom fitted in my loft and am having an issue with noisy taps - modern mono mixer. Not water hammer, but when they are half on they make a noise that I find unacceptable, yet my plumber insists this is just the way it is. However, my other taps...
  12. C

    I have fitted flowmasta bottom fill valve. the water flow

    I have fitted flowmasta bottom fill valve. The water why flow is very slow. Anyone any ideas why
  13. V

    flow sensor and flow switch help on ecodan hybrid setup with boiler

    Hi guys, I’m in the process of installing ecodan 8.5kw hybrid setup with my boiler existing boiler and a buffer tank. Heating zone 1 only (central heating ) I’ve been studying the manual and have had discussed plans with a local plumber to place pipes in for me. I’m not sure with one part...
  14. S

    New taps, poor flow rate

    Fitted these new bathroom taps yesterday. Hooked them up to 15mm pipe work which is on a gravity fed system. Upon first use it was obvious the flow rate was much worse than the old taps. Other than the taps themselfs, the only difference was that i had to fit a 15-10 mm reducer from the...
  15. F

    Hot water decreases flow after 5 minutes (electrical)

    I had a new electrical water heater (Rheem) installed in our apartment - before it was inside the closet, but now we installed in the basement of the building. Due to the new layout, the main hot line is connected to a different point, near the laundry shut off. The old heater tank connection is...
  16. K

    TAS2000SR Flow Rate Dial not working

    Hi I've just purchased a TAS2000SR but once connected the flow rate dial doesn't seem to change the flow at all. Its completely the same no matter which way the dial is turned. The only difference to my old AS2000XT is that I've located the new one TAS2000SR ~2m further away on the opposite...
  17. S

    Combi boiler over flow pipe?

    I have a end terraced house. Boiler attached to concrete wall on the end of the terrace. There’s a copper pipe curved into the wall with maybe a 1-2cm gap. The water sometimes leaks onto the wall and I’m worried about the damage it might cause. The kitchen drains are on the other side so would...
  18. S

    Mega flo issue: no water flow from hot tap, cold tap ok

    Hi all, I recently re pressured my mega flo, isolated water then drained water into tundish etc. Turned on hot water tap and no water coming out. I turned on cold water two and the water pressure and flow is ok. Does anyone know why there is no water coming out of the hot tap? Thanks
  19. A

    Any luck rifeng flow meter?

    Any luck on the rifeng flow meters . I’m looking for two fine thread too !
  20. A

    Cold water flow problem has stumped 3 plumbers...can you help?!

    Afternoon all - We have a problem with very little/no cold water flow on the ground and first floor of our (fairly new build, 7 years old) 3 story town house. All flow is fine on the top floor and the hot water is unaffected and runs throughout the house. It's an unvented, balanced system...