flush

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

flush

  1. M

    Best flush cones for low level cistern connections?

    Any recommendations other than the usual clear ones that seem too rigid most times? I’ve tried the white rubber ones as well but sometimes they don’t allow the pipe to insert fully.
  2. G

    Concealed cistern o/flowing any tips what make is it. Pics encl

  3. G

    Where does the bellows fit on a Grohe adagio single valveflush?

    I can't see whether the bellows which activates the flush is supposed to fit inside the opening at the top of the valve or press down on the edge. It doesn't seem to be aligned with the top so I don't know what's up with it.
  4. C

    Close coupled seal for 2" flush with 100mm OD?

    I'm trying to locate a close coupled cistern seal (foam or rubber) for a 2" flush with a 100mm OD and 67mm ID. All I can find is 105mm, 107, or 110mm OD. The pan recess for the seal will only accept 100mm OD. Any ideas on where I could go?
  5. damobolton

    Ideal Standard Dual Flush Cistern Overflow Problem

    Any help greatly appreciated. It appears that every time i flush the toilet the cistern fills up then overflows back in to the toilet. This can last for 2 minutes or is continually running. I have replaced the cistern dual valve as it was very loose and parts had broken off it and it wasn't a...
  6. whitegold

    Mains Water Closet direct Flush valves still a rarity in UK?

    Just was at a caravan site in Lake District recently, which had some very interesting Delabie electronic tap and shower fittings, also direct WC flush valves which worked extremely well. Always wondered why these valves didn’t seem to catch on in UK when very many other countries never use...
  7. T

    Toilet flush button cistern replacement

    Hello I’m trying to find a replacement flush button but although the thread looks like a siamp I don’t think it is. I found what I thought was the correct button but it didn’t have a strike bar which should fit in a rectangle hole in the centre of the top thread. I’m wondering if that bit was...
  8. A

    Blocked sinks, gurgling and toilet flush problems

    Started having drainage problems yesterday. The washing machine waste pipe backed up, so did the kitchen sink. I have an upstairs bathroom (toilet,sink,shower) and a downstairs toilet and sink. The downstairs toilet sink backed up also. The upstairs bathroom all drains like normal, but when I...
  9. P

    How much would you pay for a universal flush valve that enables replacements in under 5 minutes?

    How much more would you pay for a flush valve (drop valve) that was completely universal and enabled you to replace a flush valve in under 5 minutes.
  10. D

    Shower cold/warm - hot when flush tap

    Can anyone help My shower is warm, but when I flush the toilet or leave the cold tap on, if gets Hotter. The temperature I imagine a shower should be. How to fix this. Can anyone help
  11. L

    Toilet flush pressure question

    Hello, I have a question on flush pressure. When I press the bigger button, there's hardly a flush. I understand that's normal but it's a very minimal flush. And then the smaller button is quite hard to press and I think doesn't do a full flush either. So when I flush I press both and it works...
  12. Luca

    Internal cistern flush valve replacement

    Hello, I have to replace the flush valve and/or the washer but unfortunately it's inside the vanity unit. The only way is removing the toilet. I turned the screw on the cistern pipe to stop the water. I removed all the silicon around the toilet, now I can easily lift up the Front panel but...
  13. W

    Ideal standard push Btn flush valve

    Hi all, I am trying to find an alternative flush valve to fit the cradle of a ideal standard push btn flush. It is all tiled in and changing to a Siamp or fluidmaster is not an option anyone have any ideas Thanks
  14. J

    Comfort height toilet flush pipe

    Hi guys So a bit of a dilemma Normal WC Unit height 766mm which is around the average mark. quite alot of bogs lets say the flush pipe center from floor is 330-340ish. However I have a comfort height Pan here and the center to the flush pipe from floor is 405MM So we're looking 65-75mm...
  15. M

    Flush valve with handle

    Has anyone if this flush valve using the handle instead of the button? Are they good?
  16. C

    Need help to find sealing washer for this flush valve.

    Hi all, can anyone identify this flush valve, there are no manufacturers marks on it, the seal needs replacing, thanks.
  17. D

    Do you need a power flush still with new rads

    My Mother-in-law was quoted £1,000 by British Gas to do a power flush on her system as her rads aren't performing well. I was wondering, as 4 radiators need to be upgraded to doubles, would this need to be done if they are drained off and replaced? How does one actually know it needs a power...
  18. B

    Water in my house cut out after toilet flush

    We have recently had water hammer issues. Plumbers have installed an arrestor near our kitchen sink and a device in the toilet cistern to slow water shut off. Worked for a bit, but hammer returned. This morning, while the toilet was refilling and the shower was on, there was a loud thud that...
  19. B

    Replacement Cistern flush valves

    My toilet flush valve is continually draining (the rubber seal has perished) . . . I'd be grateful if someone could give me a link to parts that will fit in there and replace the current valves?
  20. P

    Drain down/flush options for combi return that goes up not down.

    Hi All This is following on from thread I made a few days ago but can't seem to find I'm in a bit of a bind with my CH design where I want to sort all of my rads and do some other bits including fitting a filter but I'm stumped on how to drain down due to how the system is put together...
Back