Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

heating system

  1. Deanoss

    Advice for heating system to install

    Hi Guy's, I am moving into a property that currently has storage heating and no gas supply. The hot water system is a vented set up with tank in the loft and cylinder in a cupboard under the stairs. I have arranged for a gas connection to the house but am left wondering what to do for the best...
  2. G

    sealed heating system air lock problem

    Ive now got to run a heating zone through a flat roof structure where the pipes will have to rise 300mm for 8m before dropping to a single rad using plastic pex pipe. Its obviously a sealed system but im worried about airlocks. Has anyone done something similar with no problems. What do you...
  3. D

    Help with my Y plan heating system please

    hi everyone I’ve noticed a small issue with my heating and it’s bugging me because I can’t put my finger on what’s causing the radiators to randomly come on when our Nest therm is off. I don’t think the Nest is at fault because the heat link is not showing “Heat on” lights when the boiler...
  4. K

    Central Heating System Noise

    I've recently moved into a rented property. Its an old terrace house that's had a great refurb. My problem is they have fitted a brand new Ideal i-mini boiler. The central heating and hot water works fine but there is an irritating hum around the house when it's on. Its loudest when it comes on...
  5. M

    Multi input heating system

    Hi First thread so hopefully I am in the right place. I will try to give all the information as best I can, however please request more details if this request is lacking. We bought a house about 4 years ago from a plumber. It contains the following heating inputs. A 16kw boiler stove A...
  6. M

    Cannot fill my closed loop heating system

    I am having a strange problem trying to repressurise my closed loop system. I believe there is a (small?) underground leak in the system as the pressure regularly drops. Typically takes a few days So regularly I repressure the loop with a feed valve. There is a pressure meter near the feed...
  7. B

    Constant air in central heating system

    I used to have a duel fuel system at home where I had oil heating and a multifuel stove with back boiler linked up to the heating system and they worked fine together for years. Around a month ago I got the oil taken away and a new worchester gas boiler installed. From this work was carried out...
  8. O

    Flushing central heating system

    How often do you flush , replace inhibitor in closed system. Partly extended in 2008.
  9. M

    Issues with commercial heating system

    I have got a problem with a commercial system. One zone is working fine, the other isn't. There are two vaillant boiler linked together through a low loss header and controlled by a VRC 630 control unit. When the zone which is causing issues is turned on, the zone valve opens as per the...
  10. M

    TF1 Omega Filter on heating system

    Hi all, not on the tools now days just the odd job for family and friends. Need to put a filter on the heating system my problem is all the pipe work goes from the boiler into the loft and across the loft floor, (Bungalow) the only place to put filter is between the boiler and ceiling 9" (228mm)...
  11. R

    How does my heating system work? Very confused

    Hi all, just bought a house and can't for the life off me figure out how my hot water is been heated.. I had a Honeywell controller thingy that I swapped for a hive, when I turn on central heating boiler fires up etc house gets warm all is well but here's the bit that confuses me... When I turn...
  12. mbc0

    Creating A Multi-Zone Heating System

    Hi, I have bought quite a large house to renovate and have completed the upstairs but am now wanting to create a multi-zone heating configuration. I have bought a nest thermostat, we already have many google home's in our house so this was a logical step. I am not a plumber but can get my...
  13. A

    Constant Pressure drop on central heating system (grant boiler)

    We purchased an incomplete house 2 years ago. It was a bargain so we were prepared for possible unpleasant surprises. So far the only major problem we are having is the heating system. In Ireland during the big freeze there was issues with central heating pipes bursting. Our house was a vacant...
  14. B

    Wirsbo Under floor heating system, downstairs totally cold :(

    My system is split into upstairs and downstairs. The upstairs is working fine but the downstairs is off. There is no hot water in any of the pipes in the downstairs system, the pump is on/warm and there are gurgling noises, but all pipes are cold even under the tap (like a radiator tap) Any...
  15. T

    Advice on new heating system?

    Hi Folks, Not sure if I am in the right place but looking for some help from more enlightened ones on the issue of home heating. My current situation is as follows. I live in the UK in a 1970s 3 bed room semi detached. Oil fired boiler, open front fire with a back boiler that heats the hot...
  16. R

    Need to identify 2 zone heating system issue

    Hi all i've come cap in hand to ask for help identifying a heating issue i've found myself involved in. Backstory is all the pipework is done and the system is operational. Zone 2 valve is operated by a flowmasta wireless thermostat. The boiler has a switched live and is not operated by flow...
  17. K

    Help what heating system is this??

    I am currently purchasing a property that has a cooper boiler. However in a couple of rooms there is small brown boxes that appear to look like speakers. However the estate agent seems to feel they are part of the heating system any advice would be great I have attached a picture for reference...
  18. G

    Glow-worm central heating system not heating up properly

    Hi I'm looking for some help or advice about why my central heating is not heating up fully. The radiators are heating up a bit, but most are not hot. The upstairs ones near the boiler are hottest. The boiler is a Glow-worm Ultracom2 30SXi. Looking at the control panel, the temperature is...
  19. T

    Hive Heating system- wiring the thermostat

    Hi there, I just bought a Hive Active Heating to replace my Honeywell CM900 thermostat (R6660D) linked to myVaillant Combi boiler ecoTEC plus 937. I would like some help re wiring my new Hive thermostat. At the moment I have a blue cable wired onto the N, red cable wired onto the first L, a...
  20. P

    new heating system for annexe, part 2

    Hi everyone I'd appreciate any suggestions with a heating solution I'm looking for. I have had 3 engineers come round for an opinion and quote and they all have different ideas. I am sure this heating system can be simplified, and be built cheaper - all the quotes are about £6-7,000...