I have a Viessmann Vitodens 222-F FS2B 26kW Storage Gas Boiler installed in 2014.
The boiler has developed a problem recently where it short cycles but only when hot water is used.
When hot water is turned on (on any tap in the property) the boiler remains off for about 45 sec. At the...
My partner has an Alpha CD25C fitted and worked until a couple of weeks ago. Intermittently it will switch off after working for 4-5 days.
When checking the boiler lights A + B flashing red alternately and light D is green. Tried doing a reset and switching off the main power and restarting...
Hi all
Just had a new mains water pipe fitted and the hot water is very slow almost a trickle. We have a combi vaillant ecotec pro 824 and it seems to come out fast to begin with then slows down considerably. It seems the boiler is struggling to provide hot water at the adequate rate that it...
Purchased property, all electric heating has combination cylinder doing hot water for 1 bathroom only , updating bathroom to have a shower, bath a basin and kitchen sink that needs hot water with no gas main or boiler , what’s the cheapest system to install to heat this property’s water...
I have a Viessman Vitodens combi boiler. When running the hot tap (or shower), the water comes through hot but then the boiler shuts off, water gets cool, boiler fires up, water gets hot, and so on... Only started happening a few weeks ago.
I have replaced the flow sensor, checked voltage where...
Hi all, just this morning seem to have a new problem to us with our Rayburn. Oven and central heating all operating as normal, however we have no hot water from any taps. We would normally hear the Rayburn kick in when hot water is demanded… however it is not.
Any help hugely appreciated
Hi guys. Do any of you knowledgable lot have any recommendations for hot water in a small cafe kitchen? They have a combi boiler which serves the property but she’s been having issues with it which then means she can’t open due to having no hot water? Any advice would be great.
We have a Drayton 27101 - 3 port motorised valve 22mm compression
Issue: when heating switches on there is no hot water, when you switch heating off you get hot water.
I replaced the motor in the motorised valve, everything started to work like it should. But an hour later and the same...
Hi Morning, I am looking at a new boiler and hot water cylinder setup for a house I am refurbishing and am getting conflicting advice on my question: Can I use a Combi or System boiler to have a different flow temperature for the hot water tank heater and the radiators. I appreciate the hw...
Hi all,
The hot water tap on our bath only dribbles, even when fully open. Our hot water pressure in the house isn't amazing, but it's not bad - the kitchen sink in the next door room is absolutely fine.
I tried to link a video but the forum wouldn't let me, so have attached it instead.
Does...
Hello
I have a salon and the plumbing for the hair wash basins is taken from the toilet, so when we are washing hair and the water is a good temperature, when the pump goes the water goes cold it takes a wile to come back. It used to do it a bit and now its much worse.
A plumber said it cant be...
Having a few issues with my combi boiler, its 14 years old now and due to be replaced as we are building extension, but need to get another 10 months out of the combi yet!
Was having pressure and lockout issues and the relief vale had activated couple times, expansion tank is fuel of water so I...
I have a strange fault with a Vaillant EcoTec combi-boiler.
It's 100% reliable whenever the heating is called for, ie. by the room-stats.
It's also 100% reliable when hot water is called for, ie. hot tap or shower, as long as the heating isn't running at the time. But if the heating is already...
Hi, I have an oil burner which is controlled via Tado to heat my home. My hot water cylinder is heated with water from the burner and also has a dumb immersion. I don’t use the immersion at all
And would like to replace it. The burner heats the water in my hot water cylinder with a TRV valve...
Hi.i was asked to take a look at my customer worcester 28i. When calling for hot water the boiler fires up fine and the water gets hot. After approx 30secs of running hot water the boiler shuts down. With the hot tap still running( water gone cold) the boiler then fires up after about 5sec and...
Hello, looking for a heating engineer to recommend / install a pressurised cylinder and combi boiler system.
There is ufh for a living space and two bathrooms, and radiators for the rest of the house. It's a 3 bed 2 bathroom property with solar panels on the roof, located in ringwood bh24.
Any...
Hello all,
I'm looking for suggestions on heating controls.
We'll be upgrading our boiler (To a modulating oil system boiler - EOGB Sapphire) and unvented cylinder (To a Mixergy cylinder) as we currently have a 13 year old fixed output combi boiler with a unvented cylinder which is fed solely...
Hi
We have recently had a 35kw combi boiler installed in a 4 bed 2 bathroom property.
Since the combi boiler was installed we are getting slow hot water pressure affected shower and bath I wouldn’t say it is trickling but it is not a good pressure where you feel clean. The bath takes longer...
I have an Ideal combi isar HE 24. Heating works perfectly but hot water does not at all.
Turn any hot tap on and water gets luke warm after about 10 seconds then boiler disengages and water gets cold again.
Been told it could be thermistor, or a couple of other things. Can anyone please help?
Morning All.
I hope you can help. We recently had a (mostly) successful visit by an Intergas engineer who fixed problems with our boiler randomly turning off.
However. Since his visit the hot water has been noticeably cooler than it was before.
I’ve tried to change the temperature of (DHW)...