Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

ideal logic

  1. P

    Ideal logic

    Evening chchaps are there any known faults on a ideal logic that will cause it to lock out. Boiler says check other gas appliances, I haven't looked at it yet. That's all the info I have. I'm not really familiar with them.mwas serviced recently by and all was well, by another chap in work.
  2. M

    Noisy ignition on Ideal Logic + 24 combi

    Landlords check on a year old Logic + combi today with complaints from the neighbours of noise from "the pipe outside". Turned up and it was sounding like a fog horn when it fired. Anyone care to guess the problem?
  3. G

    Ideal logic stand off bracket

    Can anyone tell me how many mm this adds to the depth of the boiler Cheers
  4. S

    Keston vs Ideal Logic?

    I've currently got a Keston C36 due to a longish flue run but looking to replace it. The flue can't be changed easily (buried in a roof void). I see that Keston were bought out by Ideal a while back and the new Kestons (C30 / C35) are rebadged Ideal Logics. The Ideal Logic is cheaper to buy...
  5. L

    Help Ideal logic 24 combi

    been trying to get this blighter working! called out recently, only firing on low rate with lot of woomping noise and as soon as it tries to go to high rate cuts out on F2 fault. 3 years old and been fine to date So: checked ionisation sensor wiring has continuity back to pcb. checked...
  6. R

    Help!ideal logic 30 f1 fault low pressure filling loop not working

    Having problems my boiler (ideal logic 30)had a f1 fault last week so toped pressure up with filling loop everything worked fine then same fault occurred 5days later so tried to fill up again but this time when opening the filling loop nothing happens cant hear any water going through and...
  7. R

    Ideal logic 30 f1 fault wont pressure up from fill from loop

    i have this boiler and have the F1 error i looked in the boiler manual on the fault and what to do topped up the water pressure with the filling loop and boiler worked fine for 5 days then the same problem occurred tried using the filling loop again but when i open the valves blue fully and then...
  8. Scott_D

    Picture request - Ideal logic or independent in box

    Strange request but has anyone got a good quality picture of an Ideal Logic or Ideal Independent unopened in the box? Doing a little picture story of a boiler swap for my website but didnt take any while in the box, I wont be fitting any more before xmas Thanks:1eye:
  9. F

    Ideal Logic call out no gas - Landlords need slapping

    Got called to a Logic + today, boiler not working. No gas it says on boiler. Investigate, gas at meter but not at boiler. Blockage I think to myself. Find a blanking cap in meter, so inform customer who reckons they are in credit but previous tenants are being chased for bad debts. So...
  10. D

    ideal logic losing pressure

    been to a logic losing pressure , iv drained boiler regassed expansion tank fired boiler hung around for 40mins all heating on fine holding at 2.5bar put tools away gone home 1hr later phone call its dropped again gone back doesn't look like its blown off, checked vessel all fine hung around...
  11. A

    ideal logic plus or ideal vogue

    Looking to purchase a boiler, i have shortlisted the following for a 2 bedroom property, we are also considering a loft conversion so there shall be a large double rad in the loft too, so i guess it would be 3 rooms... bathroom has no shower so the bath shall be used ideal logic plus 24 DHW...
  12. M

    Brown sticky residue inside Ideal Logic

    Was working on said boiler and I noticed on the inside there was a small puddle of thick brown residue, there was no visible leak from pump or anything else either, if never seen this before. I should of took a picture, anyone ever came across this nah.. lol
  13. N

    Ideal logic vs independant?

    What the difference between these 2 models? Looking in the Williams catalogue there's about £50 difference, yet the warranty is (currently) the same, so what's inside the box of one, but not the other? Cheers in advance
  14. R

    Ideal Logic + goes back to 7 yrs warranty - joined by Independent +

    A little birdy tells me that from Nov 1st all Logic + and Independent + boilers will be back to 7 year warranty.