    Ideal gas boiler sudden ignition lockout

    Hello - I have a Ideal 35kw combi gas boiler. Everything was fine until I switched the heating on for the first time this year. Then I got a L2 Ignition lockout error, and resetting the boiler doesn't fix it. The gas is definitely on, and the pressure is fine - any ideas? Thank you!
  2. J

    Ideal Logic Code Combi E38 not working

    Turned the system from hot water only, to hot water and central heating the other day. After it working briefly, it has now stopped all together. The display isnt showing a fault or anything - it is just blank. After reading the service guide that came with it - I am confident there is power...
  3. D

    Ideal logic combi boiler with mechanical timer swap with electrical

    Hi all, i moved recently in new home and realised that there is no room external thermostat wired to the Ideal Combi boiler. There is only mechanical timer on it. I saw some videos on Internet that mechanical timer can be replaced with electrical one but i am not sure if it is compatible with...
  4. P

    ideal c35 independent

    I just installed second zone onto my ideal independent c35 original I had one hive thermostat now I added two two port valves ( with Bypass) and two hive thermostat V3 it wired into a wiring centre looking at the wiring on the boiler shall I put back the room stat/ timer loop back in as...
  5. P

    Ideal Logic Combi 35 constant F1 fault

    Got up on Wednesday morning no hot water, (only cold water coming out of hot tap). Checked boiler, it had zero pressure and F1 fault showing. So I refilled the pressure using the filling loop, up to about 1bar which is where it usually is, which worked fine, had hot water all day. Same thing...
  6. F

    Pressure issues Ideal Logic Combi 30

    Hi, We have a new Ideal Logic Combi 30. A radiator today came off the wall and developed a leak. Plumber came and fixed (but didn't). At that time the boiler was fine. Today the boiler has lost pressure. I have followed the videos on yt and nothing works. Just stays telling me F1. I have...
  7. BENNEJ0

    ideal standard dual flush valve problem

    i have 3 sottini toilets with a compact cistern. It has an ideal standard dual flush mechanism. 2" entry The ideal standard is poor quality in my opinion, I have replaced the washer and complete unit several times but it always leaks within a short time (between 0-18 months), I would like to...
  8. kris

    Ideal vogue c32 (gen 1) wire link part number needed

    Hey folks, I'm wondering if someone could possibly help, I'm looking for a possible part number b4 I call ideal in the morning, I fitted an Ideal vogue 6years ago so it's generation 1 vogue c32, I also fitted a RF wireless controller (prt4) The reciever part plugs directly onto the boiler...
  9. M

    Help needed on Ideal Logic Heat 15 System Boiler showing F3 error code

    Ideal Logic Heat 15 System Boiler Hi. Just started to get an F3 Fan Fault on this boiler. On power up there seems to be a quiet thump from somewhere then it goes through the start up sequence. It spends a few seconds on the ‘c’ display before coming up with the F3 error code. Can anyone advise...
  10. D

    Ideal Icos HE12 constant F L Code

    Folks Me again I am at my wits end. I want to replace the boiler but I am on my backside and cannot afford to. I have been getting an intermittent F L Code. For around a year. I've had an engineer out 4 times. In that time boiler has had a new PCB, new electrodes, new gaskets, new...
  11. B

    Anyone fitted an Ideal Standard i.life S Basin & Full Pedestal?

    Has anyone fitted an Ideal Standard i.life S 50cm compact washbasin with a matching i.life S & B full pedestal? The basin is T518501 and pedestal is T519901. I have a problem with the pedestal boxed and packaged as the T519901 (but marked T2839 inside as below) - it does not fit and from the...
  12. F

    ideal drill bit size for 15mm pipes

    I am tiling a shower wall and need to drill holes for 15mm pipes that will go to a thermostatic valve, what size of drill bit for the holes is best?
  13. R

    Ideal Logic Combi ESP1 Time clock jumper link

    Hi looking to remove my existing rf time clock and refit the oem link, but the installer didn’t leave it, anyone point me in the right direction
  14. M_Nash95

    Ideal System 15 losing pressure; pressure dial violently twitching

    Hi there, I am renting at the moment. Our boiler is an Ideal System 15. Within an hour or two of moving in and turning the heat on the boiler lost pressure. Now it loses pressure any time that it is turned on. If the boiler pressure is set below 1.5 bars cold it will lose all pressure in about...
  15. Beshman

    Need new Thermostat for 2016 Ideal Logic Plus Combi 30

    I've got a 2016 Logic PLus Combi 30 and a Salus RT505TX RF Thermostat The thermostat seems to keep losing connection, no matter the placement. It can be next to the boiler or in the next room and it still not get a connection. Just a weird blackspot in the kitchen blocking it (could be the...
  16. S

    Ideal boiler had the F1 code, so topped pressure up but code persists.

    After researching as much as I can to sort this problem, I keep reading that if your Ideal boiler has an F1 code and the pressure is low, it needs topping up. If it has an F1 code but the pressure is fine, then this indicates a potential pressure sensor fault. What if it was low (completely...
  17. hotpointer

    Ideal Classic FF350 cuts out after 10mins

    Hello , I have an Ideal Classic boiler ff350 which runs for 10 mins before the boiler cuts out. The circ pump keeps running at this time. The Pump and The Three port valve have been checked and the User Stat on the front has been Changed (by a Gas safe engineer) when the Boiler cuts out there is...
  18. T

    Uncoded intermittent ignition fault, Ideal logic heat 18 .

    Ideal logic heat 18. Uncoded intermittent fault near end of days use only. Burner reignites every 15 seconds on and off, but no fault code showing. Boiler isolated and restarted okay but same uncoded fault repeated at end of next day.
  19. F

    Constant Lockout issue with Ideal Concord CXS/SD40/H

    In our Village Hall we have a Ideal Concord CXS/SD40/H central heating boiler. This was installed new when we had an extension built and the existing boiler needed upgrading. The Mechanical Engineers advising the architect insisted that we had a conventional cast iron combustion chamber boiler...
  20. R

    What is ideal pump size for Vaillant ecoTEC Plus15kW Heat Only Boiler?

    What is the ideal pump size for Vaillant ecoTEC Plus 400 15kW Heat Only Boiler? The property is a studio with 1 large room, a small kitchen and a small bathroom. I've been advised to use Grundfos UPS3 15-50/65-130.