I need to lower down the water pressure and have identify the stopcock at main water meter. I am not sure which one i need to buy. I have attached the picture although its not quite clear. Any advise will be helpful. Thanks
Hi. Bored and wondering about a friend's boiler that was fitted a few years ago and that, having been involved with the heating system, I take an interest in. One of these jewels...
Replaced a Willis (Belfast) immersion heating in an open vent heating system. Willis is working ok but flow of heated water see wrong and does not generate a lot of hot water.
Symptoms are (See diagram):
Flow from hot tapes fine (no air locks).
Tank heats up using house oil indirect heating...
Customer has a Main Multipoint BF that needs the diaphragm replacing. I'm attempting to remove the water valve but one of the screws that fix it to the bottom of the gas valve just won't budge. The head of the screw is completely stripped. My trusty neji-saurus screw pliers turned it about 45...
Hey guys
My wife noticed water on the floor in our basement. What I can see is that the elbow is cracked where a 1.5" down pipe enters a 4" pipe that goes beneath the basement concrete floor.
My thought is that I have to break up some concrete to replace the 4" pipe/clean out and reattached...
Hi,
Customer has a Main Multipoint Balanced Flue water heater.
Both the gas rate and burner pressure are under what the MIs state. MI state burner pressure is pre factory set at 14.1mbar and should not need adjusting and my checks showed burner pressure as 6mbar. Gas rate MI state 2.9 m3/hr...
Hi
I have an old 1950s house, and the stopcock on the rising main is quite stiff and difficult to access. I'd like to add a new stopcock in a more accessible position, but leave the old stopcock in place so that that I don't have to turn off the water at the property boundary. Is there any...
Hi all
Would be grateful for any help you can give:
Model: Redring Selectronic Premier - 2016 model
Problem: Water spewing from the bottom of the main unit instead of coming out through the hose.
I initially thought this was due to the PRV having activated but upon further investigation I...
The main circuit board has gone 3 times in the last 3 months after heavy rain. I have a maintenance contract with British Gas but they will not keep replacing the board FOC. How can I stop his happening? The boiler is 7 years old and I have not had this problem until recently so what will have...
Hi,
I'm having some issues with my current water main leaking. We had an extension put onto our house back in 2013, during which we moved our kitchen into the extension on the opposite side of the house.
The stop tap was positioned in what would become the middle of our lounge, so the plumber...
Hi all, looking for a bit of advice. I have a lovely Grohe kitchen mixer. Sadly, after many years of use, the main O ring seal on the swivel has perished and leaking badly. I've descaled her as much as possible but I am unable to release I guess, the threaded, upper part to expose the O ring. Do...
We are considering having our house rads and hot water system replumbed so it's not buried in the 1970's screed that it is at the moment. The cement progressively eats away at the copper if it is not wrapped in Denzo tape (no way to tell without digging up the screed).
We are thinking of...
Hi everyone,
I'm needing to trace a leak on copper main in screed at my son's house. Anglian Water have notified a leak of 18ltr/hr, and we've verified it's not between their stopcock and internal stopcock.
There's no signs of dampness, floors where pipes run are tiled.
Looking for advice...
central heating radiators to feed upstairs and downstairs main paperwork runs in ceiling void downstairs ,need to tee off to radiators downstairs do I tee off from above or below on the main
pipework to avoid airlocks
I have a grant vortex combi and it keeps tripping the main fuse when the programmer calls for heating.
This has just started, it was working fine before.
Anybody got any thoughts
I am perilously close to losing my mind - so any help appreciated!
About a month ago a vibrating sound started on our cold mains (copper pipes).
This noise will often go on for 12-24 hours, always a loud rumbling sound that you can feel in the pipes.
I am in a maisonette, and believe the cold...
About 2 months ago I had a plumber out to remedy a rocking toilet. He pulled the toilet, noted the flange was 1 -2 inches low. He replaced the toilet and left saying he had to get approval for the repair. That night my shower wouldn't drain an the toilet was bubbling air while the shower was...
Hi
Anyone got experiance with sizing a water main for a block of 12 flats? Im after any general tips or points that I should know, such as what water southern water might want to provide for this kind of thing? In smaller blocks that Ive done they have installed a manifold in the ground...