main | Page 3
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

main

  1. N

    Main Meter Stopcock key- How to identify

    I need to lower down the water pressure and have identify the stopcock at main water meter. I am not sure which one i need to buy. I have attached the picture although its not quite clear. Any advise will be helpful. Thanks
  2. R

    "Main" (Baxi) 24HE A Heat only boiler temperature setting

    Hi. Bored and wondering about a friend's boiler that was fitted a few years ago and that, having been involved with the heating system, I take an interest in. One of these jewels...
  3. T

    Baxi main Ecco 25 combi boiler bypass pipe 5114715 is leaking from both ends one end is fitted to the 3 way valve assy

    Baxi main Ecco 25 combi boiler the bypass pipe 5114715 is leaking from both ends one end fits into the the 3 way valve assy
  4. B

    Willis Immersion issue - no hot water getting to main tank

    Replaced a Willis (Belfast) immersion heating in an open vent heating system. Willis is working ok but flow of heated water see wrong and does not generate a lot of hot water. Symptoms are (See diagram): Flow from hot tapes fine (no air locks). Tank heats up using house oil indirect heating...
  5. T

    Removing water valve on Main Multipoint BF

    Customer has a Main Multipoint BF that needs the diaphragm replacing. I'm attempting to remove the water valve but one of the screws that fix it to the bottom of the gas valve just won't budge. The head of the screw is completely stripped. My trusty neji-saurus screw pliers turned it about 45...
  6. W

    I have a cracked 1.5" pipe elbow going into a 4" main drain under basement floor. How do I fix this?

    Hey guys My wife noticed water on the floor in our basement. What I can see is that the elbow is cracked where a 1.5" down pipe enters a 4" pipe that goes beneath the basement concrete floor. My thought is that I have to break up some concrete to replace the 4" pipe/clean out and reattached...
  7. S

    Main Multipoint BF Water Heater

    Hi, Customer has a Main Multipoint Balanced Flue water heater. Both the gas rate and burner pressure are under what the MIs state. MI state burner pressure is pre factory set at 14.1mbar and should not need adjusting and my checks showed burner pressure as 6mbar. Gas rate MI state 2.9 m3/hr...
  8. O

    New stopcock on rising main

    Hi I have an old 1950s house, and the stopcock on the rising main is quite stiff and difficult to access. I'd like to add a new stopcock in a more accessible position, but leave the old stopcock in place so that that I don't have to turn off the water at the property boundary. Is there any...
  9. S

    Redring Electric Shower - Water coming from main unit

    Hi all Would be grateful for any help you can give: Model: Redring Selectronic Premier - 2016 model Problem: Water spewing from the bottom of the main unit instead of coming out through the hose. I initially thought this was due to the PRV having activated but upon further investigation I...
  10. J

    rain water coming into Ideal Combi boiler through flue and causing main circuit board to blow.

    The main circuit board has gone 3 times in the last 3 months after heavy rain. I have a maintenance contract with British Gas but they will not keep replacing the board FOC. How can I stop his happening? The boiler is 7 years old and I have not had this problem until recently so what will have...
  11. J

    Regulations for fitting new water main from meter to house

    Hi, I'm having some issues with my current water main leaking. We had an extension put onto our house back in 2013, during which we moved our kitchen into the extension on the opposite side of the house. The stop tap was positioned in what would become the middle of our lounge, so the plumber...
  12. N

    I have a leaking pressure valve on my Main combi eco elite

    I have to replace my pressure relief valve on my Main combi eco elite as it is leaking , what sort of job is this ?
  13. K

    Need help opening up a Grohe mixer tap to change the main swivel O ring

    Hi all, looking for a bit of advice. I have a lovely Grohe kitchen mixer. Sadly, after many years of use, the main O ring seal on the swivel has perished and leaking badly. I've descaled her as much as possible but I am unable to release I guess, the threaded, upper part to expose the O ring. Do...
  14. B

    Hot water ring main in the bungalow roof void rather than screed

    We are considering having our house rads and hot water system replumbed so it's not buried in the 1970's screed that it is at the moment. The cement progressively eats away at the copper if it is not wrapped in Denzo tape (no way to tell without digging up the screed). We are thinking of...
  15. J

    URGENT Where to hire leak detection equipment for copper main in screed?

    Hi everyone, I'm needing to trace a leak on copper main in screed at my son's house. Anglian Water have notified a leak of 18ltr/hr, and we've verified it's not between their stopcock and internal stopcock. There's no signs of dampness, floors where pipes run are tiled. Looking for advice...
  16. K

    Avoiding airlocks in central heating system teeing off from the main pipework

    central heating radiators to feed upstairs and downstairs main paperwork runs in ceiling void downstairs ,need to tee off to radiators downstairs do I tee off from above or below on the main pipework to avoid airlocks
  17. D

    Boiler keeps tripping main fuse

    I have a grant vortex combi and it keeps tripping the main fuse when the programmer calls for heating. This has just started, it was working fine before. Anybody got any thoughts
  18. T

    Noisy pipes on cold main

    I am perilously close to losing my mind - so any help appreciated! About a month ago a vibrating sound started on our cold mains (copper pipes). This noise will often go on for 12-24 hours, always a loud rumbling sound that you can feel in the pipes. I am in a maisonette, and believe the cold...
  19. J

    Wax ring in main sewage line

    About 2 months ago I had a plumber out to remedy a rocking toilet. He pulled the toilet, noted the flange was 1 -2 inches low. He replaced the toilet and left saying he had to get approval for the repair. That night my shower wouldn't drain an the toilet was bubbling air while the shower was...
  20. M

    Water main for 12 flats

    Hi Anyone got experiance with sizing a water main for a block of 12 flats? Im after any general tips or points that I should know, such as what water southern water might want to provide for this kind of thing? In smaller blocks that Ive done they have installed a manifold in the ground...
Back
Top