  1. phil hair

    main combi 30 eco diverter valve

    hi, i have a main combi 30 eco that has heating but no hot water. I changed the diverter cartridge but that did not fix it. the hall sensor is on, the diverter motor is working, the preheat is working , and although the 'tap' led is lit up, the fan doesn't start, no ignition,ect. should i have...
  2. O

    main water upgrade ..........

    Hi Lads, Could anybody tell if I am allowed to upgrade a mains water supply with 25mm plastic from outside the new mains stopcock ( which is on the footpath ) to the staircase at the property? its basically a straight run of 7-8m? the customer has got already the new stopcock put in at the...
  3. Hobo128

    Main 24he hot water fault

    Main combi 24 he. When i open the hot water tap the pin from the diverter only comes out slightly not enough to make contact with the micro switch. I am going to change the diaphragm tomorrow with hope that this will solve it which it usually does but i have had it where it doesnt make much of...
  4. H

    noisy main 18 he heat only boiler

    Hi guys, Got a customer with the above boiler that makes a loud noise on start up then stops. this happens intermittently, any come across this?
  5. R

    Problem with rising main tap connections

    Our old mains water tap seized, so we had it replaced a couple of days ago. The original was brass, connected directly to the blue supply pipe, with a smaller outlet going to a pressure control valve with a pressure gauge. The replacement is as shown in the photo. About 40 minutes after it was...
  6. M

    Main combi eco30 pressure fault

    Good morning all, I have been having some issues intermitently with my own boiler, if left off sometimes over night the pressure gauge drops just below the .5 bar mark, the boiler then wont fire up. Commence the topping up via filling loop into green zone around 1 bar (cold) and once boiler...
  7. sammathias

    new build sprinker system/32mm main

    I was told today that apparently on new builds that sprinkler systems are required to confirm with building regs and that a 32mm main is required as standard.... is this just a load of hot air or???
  8. S

    Main he heat only boiler

    Got a boiler service on a main he boiler on Thursday. Never worked on a main boiler before. Anything to look out for? Said keeps cutting in and out so first check will be electrodes. Cheers
  9. D

    15mm rising main to 4 apartments?

    Hi I’m currently working on a 3 story house that’s being converted into 4 flats. I installing 40kw boiler, 15 rads, 4 Heating zones plus a hot water zone. Etc etc Each flat has a kitchen sink, toilet, basin and electric shower. Problem is, I’ve got a 15mm rising main. ‭Im hoping it’ll just...
  10. Matt0167

    Main Water heater problem

    Hi Guys Need some help of you more experianced guys if anyone could help Main weater heater 52-476-40 lighting on to main burn once you light the pilot, as soon as you've energised the pilot and release the pilot button main burner comes on even though there is no open tap, faulty gas valve...
  11. N

    Need help about a parallel pipe with the main pipe

    Need some help to understand an additional pipe and its reason which comes out from the main pipe and then joins back in to the same pipe but with a service valve in between . I am looking for a good place to connect the water softener in my main pipe. I would like to keep the drinking water...
  12. M

    Main 15he secondary hex leaking

    Hi chaps. I have been to the above boiler where there is water running down the side of the combustion chamber. Where the secondary hex is on the opposite side. The connection where it is leaking looks like aluminium foil? Anyone got any experience of these and can advice. Please see the image...
  13. D

    Baxi Main eco 30 combi Heat exchanger screws burred

    Help! Above boiler needs H/E cleaning or replacing but looks like some one tried before and they have completely burred the inside of the screw. The screw looks like it has an 8m external socket head but less than 1mm protrudes so can not get a socket on. Any one with any idea how to get these...
  14. P

    Distance from main supply pipe or bolier most importnat for balancing

    Im going to balance my radiators because some are struggling, but I would like to understand the calc better. I have a central 22m supply and return pipe running from far left of house to far right of house through first floor joists, Boiler is at far left, pump is near boiler on supply pipe. I...
  15. M

    Working out the weight of lead main

    Hi, can someone tell me how we worked out the weight of lead per foot by using a piece of string and wrapping it around it? I cannot see it on the search bar any where. Cheers
  16. T

    Main mersey super multipoint burners staying lit

    Any ideas please on why burners are staying lit when hot taps closed? Recently had thermocouple replaced.
  17. U

    Advice on fitting a stopcock to lead rising main

    Hi all, I've realised that our 2nd floor flat doesn't have a stopcock where the rising main comes into the flat or it is under a floor or something. We have gate valves or stop cocks in front of kitchen sink and cold water cistern for bathroom for servicing, however all of them are either...
  18. H

    How should I connect to a 4 inch cast iron water main

    Hi I want to replace some old iron water main pipe and broken stopcock ideally with a larger bore pipe eg 28mm. In digging into the basement floor i found that the rougly 1 inch iron pipe comes off a 4 inch? Cast iron pipe. Not sure i dare try to unscrew the end cap. Should i just cut the iron...
  19. phil hair

    leaking HX manifold main 24 he

    hi, i have a main 24 he with a heat X manifold that has had small leak on it for a while, the inside of the box was all furred up. ive cleaned it up and replaced the manifold, but for the life of me, i can not get it to seal. What can i use to make it seal? something like plumbers mait? would...
  20. RoryD

    Main Eco combi 30 DHW Problems

    CH works ok. When there's a demand for DHW the boiler fires, modulates and then stops. The process then continues in this fashion ad nauseum. The flow pipe from the Heat exchanger doesn't get hot, the pump continually "surges" on/off and gets very hot. When the preheat kicks in the pump...
Back