Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

plus

  1. J

    valiant ecotech plus 624

    Damsel in distress....I have a valiant ecotech plus 624 boiler and suddenly I have no hot water the boiler feeds a tank in the airing cupboard. I have tried everything and did succeed in getting hot water but only if I also put the CH on! There are no fault numbers showing. Could this be the...
  2. Y

    Vaillant Ecotec Plus 624 question- only radiator sign comes up

    Dear All I recently had the above Vaillant stem boiler with megaflo system installed. I have 2 issues if someone could please kindly help: 1. When I check the control panel no hot water tap symbol appears. Only the radiator symbol even when hot water is switched on. Is this normal or do I...
  3. S

    Vaillant TurboMax Plus Boiler Issue - Fan not working

    This week my boiler failed giving an S.33 message "Check air/flue system" message. My plumber came around and identified the problem as a failed fan. I had my old fan handy (I replaced it 4 years ago due to it becoming noisey). He fitted that and all was well. However, when I next tried the...
  4. M

    Vaillant ectotec plus 824, hot water but no heating.

    Hi all. I'm a bit stumped with regards to a repair I've been called out to.
  5. L

    Ecotec plus 824 r1

    Hi chaps Have one of these that builds temp within 30 secs and cuts out in heating or hot water. Vaillant have told her she needs a flush but the rads are brand new and the water looks like drinking water. Don't think a flush will cure it. Wondered if anyone has come across the same...
  6. B

    Worcester Bosch Greenstar R40 HE combi plus

    Hello, I have a worcester Greenstar R40 HE Combi plus that had been over heating and coming up with Fault code E9. I have had two engineer visits with the first one replacing CH sensor and DHW flow sensor. And the second engineer replacing fuses on the mother board. The boiler still overheats...
  7. C

    Vailant Eco Tec 630 Plus Filling Loop leaking not refilling system bucket collecting

    Hello we have a Valiant Eco Tec 630 plus which was functioning fine however the pressure was low so we opened up the filling loop - water came out of the loop system under pressure 'like a back pressure' from within the sytem itself which meant water was spraying out from the valve head until...
  8. woodsy

    Potterton profile 80e to Vaillant ecotec plus 430

    Been asked to change a Potterton to the Vaillant - not fitted the Vaillant before so looking for any possible headaches , wiring alterations etc that I need to take into account.
  9. P

    Vaillant 415 ErP Ecotec Plus or Baxi ecoblue advance 25

    Evening all I need to get a new boiler and have got quotes from 2 installers - one for the Baxi ecoblue advance 25 and one for the Vaillant 415 ErP ecotec plus. I am in a quandary as to which to go with. Any views please? Thanks in advance Ian
  10. J

    Low Pressure on boiler - Help! (Vaillant ecoTEC plus 618)

    Hi guys - I have a Vaillant ecoTEC plus 618 VU GB 186/5-5 that's showing a low pressure error. I understand I have to top up the pressure by turning/releasing some valves - the only problem is I have no idea where they are! I can't see any 'grey taps' and tried reading the manual but it's quite...
  11. I

    Vaillant Ecotec plus - Pressure Low and wont fill up

    Hi guys, Woke up this morning to no heating and hot water. Looked at boiler and pressure was low. Tried to top up using taps underneath but nothing flows through. Disconnected braided pipe and turned on and water comes through. I will call engineer out, but wondered if there was a way of...
  12. N

    New boiler combo swap needed, plus capping and moving a few gas pipes in West Norwood

    Hi, Just joined the forum, I'm renovating a house and need a boiler combo straight swap for a new alpha intec 30c, plus capping and moving a few gas pipes in West Norwood, SE27 If anyone can recommend a good gas safe registered plumber, or provide us with a quote, that would be great. Thanks...