power | Page 8

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

power

  1. Riley

    Power flush blues

    Power flushing. Bored. Entertain me!!!!
  2. K

    Worcester Bosch 30cdi - no power to the pump?

    Home owner here. All was working fine this morning. Now the boiler comes on and quickly runs up to to over 100 centigrade and then cuts out for both CH and HW singly or together. I have checked the power to all the 3 port valves and there is power. There is no power to the pump (a typical red...
  3. M

    alpha he cb25 no power no lights

    hi hope someone can help me. my bolier alpha he cb25 has stopped working. no hot water no heating. there are no lights at all. its as if its no power just dead. followed trouble shooting in manual leads to replace pcb???? checked all fuses all fine any help would be great to close to christmas
  4. U

    alpha he cb 25 no power or lights

    hi hope someone can help me. my bolier alpha he cb25 has stopped working. no hot water no heating. there are no lights at all. its as if its no power just dead. followed trouble shooting in manual leads to replace pcb???? any help would be great to close to christmas
  5. L

    No power to boiler unit

    Hi, I have a Worcester Greenstar oil boiler about 6 years old. It suddenly stopped working, the pressure guage is OK but wall gauges are showing blank. A red light is showing on front of unit. Any advice would be most welcome, thanks
  6. P

    A few Milwaukee power tools

    I have a few Milwaukee power tools for sale. All tools are used but in great condition as I am a little OCD about my tools. I have two 18 volt 1/2" hammer drills. I am asking 40£ for one and 50£ for the other one as it is newer and in better condition. I also have a 1/4" impact driver for 45£...
  7. D

    Combi Boiler Dripping when Power Switched Off

    Hi all I've got a Glow Worm Ultracom CXi30 combi boiler which starts dripping water when the power to it is switched off. The house is 6 years old and the boiler was installed when it was built. This happened once about 5 years ago when we went on holiday and the in-laws popped in and...
  8. T

    Power flush cleaner debate

    Evening lads, what cleaner do you use when flushing???? i go for fernox f5, won't trash a boiler and errrrr it's what they sell at my counter lol
  9. finchy01

    Power tripping when dhw/ch demand.

    Evening all, I had a call back today from a month ago or so. The power trips when a) immediate demand for dhw and b) a few seconds after demand for ch. We replaced the programmer, cylinder stat and 3 port before (a different reason). This has only started a couple of days ago so I know it's...
  10. T

    Power flush a grant oil boiler

    Been called to flush a system that's running a "exposed" grant oil boiler. It's been in place for a year. Advice please are they ok to power flush or should I bypass the boiler
  11. U

    Scottish Power Connect / Climote, any experiences ??

    Hi I found this smart thermostat product on the web and am interested in it for a property that's not always in use. I can't find any user feedback anywhere else on the web and wondered if any of you professionals had any experiences you could pass on, positive or negative ! It's sold in...
  12. G

    Recommended power flush company in the Southend on sea area

    Hi all Can some kind soul recommend a decent power flush person in the Essex area Thanks Gary
  13. A

    power flush on a oil fired combi

    Hi fellas, have a power flush lined up for later this week - use a Fernox machine and have done quite a few in the past but never on a combi boiler. This boiler is a Warmflow Kabin Pak system boiler with the twin head pump. I would normally attach the power flush machine to the pump valves but...
  14. L

    Power flushing

    Hi all, when you want to power flush a combi boiler and you turn the mains power of to the boiler, how do you know if the diverter valve is in central heating and not hot water? I.e. the water is being pumped through the main heat exchanger? :drool5:
  15. D

    Salus IT500 killing pump power after hot water cycle is complete

    Hi, I have a Salus IT500 controlling my vaillant ecotec 418 open vented boiler. The hot water is heated for 2 hours and when the time is up the Salus stops the water heating cycle and leaves the boiler to cool down. The boiler shows the pump symbol for the external pump running, but the salus...
  16. AlexGas

    Power Flush...

    I use Power Flush FX2 and the crystals to clean the CH pipe work. I find that it takes ages to get the dump water clear. It took me less than 20 min to do the job by using mains cold water pushing all the dirty water out. 2-3 min per rad, job’s done. OK, it’s a bit of waste of water… What are...
  17. B

    Myson Power Extra MPE322 Problem or not?

    Hi guys I have a Potterton Boiler this heats up the radiators and the hot water. There is also an immersion heater in the airing cupboard too that we leave switched off. Our water was cold the other day and we noticed when the heating and water lights come on on the timer panel the pilot...
  18. B

    Myson Power Extra

    Hi guys, I am new here so would like to say hello All! Is there anyone that could help? At Christmas last year our boiler started playing up its a Potterton that isn't a combi. McAllen the insurance they sent a guy out who replaced the pump in the airing cupboard and then realised that the...
  19. T

    Which power shower would best replace an Osprey 11?

    Hi all, I've got an old power shower to replace and would of course like to make it look good (no visible pipes etc...) but the one I'm replacing isn't made any more. Here's a photo of the insides including where the pipes go into the unit so I'd be very grateful if anyone's got any relevant...
  20. spanner

    power flush

    I'm looking for a decent power flushing unit at a good price.. any offers??? Kamco preferred, and the decent CF90 I'm able to get brand new for £500
Back