pressure | Page 10

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

pressure

  1. N

    Low cold water pressure only in bathroom

    Hi, I’m new to the forum and would really appreciate some advice on this problem I have with my bathroom cold water pressure. We recently moved to this one bedroom flat and our hot water comes from a communal boiler in the basement. In the kitchen the water pressure is good for both hot and...
  2. Orchid_2022

    High Pressure Commercial Toilet

    I am looking for suggestions /advice on getting a commercial high pressure toilets that does the job in one flush. Does anyone have any toilets they can recommend?
  3. Arelia

    Water pressure in British homes

    Good morning, Can anyone tell me what water pressure British homes have? Thx in advance
  4. P

    Why the sudden drop in kitchen faucet water pressure?

    Just had strange occurrence and hope someone can please help. Noticed a small leak under kitchen sink. Wanted to troubleshoot shut off valves for possible leak, so I turned them off and on moved them back-and-forth some to check for leak. Nothing. However, upon reopening both supply valves...
  5. C

    Gas Boiler 0 pressure

    Hi, was wondering if I should turn my gas boiler off and on, it's a new boiler in a new build house, it's been going fine for a few weeks but it's flashing 0 bar on the display, the pressure gauge red needle is at 4 bar and the black is at 0.5 bar just not sure what to do before contacting the...
  6. B

    Water pressure in kitchen unbalanced query

    Hi everyone, I have a question about balanced water pressure in my kitchen. Are both the hot and cold water pressure meant to be the same, as my hot water has good pressure when fully open but the cold tap pressure has about 2-3 times more pressure when the tap is fully open almost floods the...
  7. R

    Pressure loss in new loft (unvented cylinder)

    Hello. I need some urgent advice re water pressure in an unvented system. A few months back, I had my gravity fed system + boiler changed to an unvented cylinder + system boiler. The water pressure following the swap was incredible. We were originally talking about putting in a mains booster...
  8. G

    Pressure rising on an unvented system

    Hi all, The pressure bar in my unvented system is rising. It’s set at 1.5 and rises to 2/2.5. I know it will rise when the water is heating but this now doesn’t drop. I have an Oil boiler and at present only the hot water is on. I have reduced the pressure by bleeding a radiator. My question...
  9. P

    My Mains water pressure has dropped after annual boiler service

    Hi, new guy here. I've just had my annual service on my combi boiler and the mains water supply pressure appears to be lower. Is there anything they could have done to cause this?
  10. C

    Low water pressure in bath mixer tap for shower head?

    Hello - am hoping someone out there can offer some advice... I've been living in a split level 1st & 2nd floor masionette for two months, which was built in the 60's. Heating is provided via combi boiler. Water for kichen is fed straight from the mains supply (both hot and cold), however, we...
  11. C

    Garden tap low pressure and hissing

    I’ve just noticed my outside tap is making a sort of hissing sound and the pressure doesn’t seem as good as it was. It has much less power coming out of the hose pipe. A few months ago the return valve was fixed as it got stuck could it be related to this? I’m happy to try taking it apart to see...
  12. S

    Closed loop pressure increasing

    Just wondering if anyone has even seen an issue with the pressure gradually increasing on a closed loop system where there is no fill loop attached. I'm seeing this issue on a gshp and whats more unusual is its on the cooling side. If it was on the heating side you could put it down to expansion...
  13. K

    Variable water pressure causing electric shower problem

    I have a B&B that has had lots of plumbing issues in the past e.g. hot water to a toilet! I am fed up of spending money so hoping someone can help as several plumbers so far have been hopeless. The latest problem is that I had an electric shower replaced because it was cycling between scalding...
  14. E

    What boiler pressure loss is ok over time?

    My Ideal boiler pressure gauge pointer shows about 0.85 when cold (about 1.8 when the heating is on). 10 weeks ago the readings were 1.0 when cold and 2.0 when hot. Clearly there is a loss in pressure over time. I can see no leak on any radiator or near the boiler. Is this pressure drop of...
  15. J

    Can you increase water pressure to your home?

    I have a unit (1 of 3), and mine is furtherest from the road. I have fairly crap water pressure and have had the water corp out, who agree its crap, but claim its due to the distance from the mains. Is there something that can be done to increase water pressure?
  16. M

    Pressure reducing valve - can I remove?

    As part of full house renovation, I've switched from a conventional boiler/gravity fed tank to a combi boiler. Under the old system I note that a pressure reducing valve has been fitted to the pipework feeding the shower mixer (assuming as mains cold overpowering the supply pressure from the...
  17. M

    Poor flow and pressure issues?

    Hi guys. I replaced an electric shower for a family member recently and on completion noticed how poor the pressure was. It wasn’t like this the week before when I initially looked at it. Apparently Severn Trent were in the area the following week to do some work. She’s now saying that the...
  18. A

    Not able to put pressure in vessel

    Had a main water leak lately and fixed it it had been there for a few days and the boiler wasn't working after the repair I tried to pressurize the vessel in the hot press but couldn't pump air in I took out the valve stem and inserted a blunt stick in but it wouldn't go in seems like it's...
  19. N

    Combi boiler loosing pressure fast

    Hi all, back again with yet another question about my grant vortex combi boiler 😩 Sorted all previous problems and was running sweet until recently… now it’s loosing pressure really quick, from 1.5 bar down to 0 in a couple of hours (even when on standby neither hot water or central heating...
  20. N

    Pressure drop on test guage, nothing at meter

    Hi all, I am wondering if someone can make sense of this. I have been trying to determine if there is a leak on an existing water supply pipe. Attached a dry pressure guage to garden tap and turned tap on. Pressure went to about 3.5 bar then I shut off supply at the water meter. Over the next...
Back
Top