replacement | Page 4

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

replacement

  1. B

    New Boiler Replacement - Clarification/Advice Required

    Hi, I have a Y plan open vent system, boiler 30+ years old, and requires replacement. My plumber is recommending fitting a new Viessmann 11kw System boiler in the current boilers position. The problem is he plans to run two new separate pipes fro the boiler to the hot water cylinder. Once this...
  2. blellum

    Replacement for this old shower...

    Hello forum, We have a leak in a 28 year old shower, and decided it should be replaced. However, after getting the cover off, it seems the entry pipe is more or less fixed in place!! Any advice on a replacement? I was looking at Mira Sports, but the entry is on the left - the multifits are ok I...
  3. Ivington

    Dripping tap cartridge replacement but problem eventually returns

    I have a dripping tap that was getting progressively worse over the period of about 4 to 6 weeks and have replaced with a brand new cartridge on 2 separate occasions, but after 4 to 6 weeks the problem returns.
  4. Andrew Garrett

    Worcester Bosch i30 Greenstar PRV and Expansion Chamber replacement

    Hi all What kind of time is required to replace the Pressure Relief Valve and the expansion chamber in a 6 year old Worcester Bosch i30 Greenstar? Is this a 3 hour job? Also what kind of price would be reasonable? I am using a new gas engineer and I want to verify that his bill is fair. I am...
  5. N

    Still worth getting a replacement gas boiler?

    Our ~15-year-old boiler just broke down (the spark igniter gave out), and set out a discussion to go ahead and replace it, as it's starting to kettle as well, and it will probably just be downhill from here. Background: 1905 built (renovated in 2010) Edwardian terraced. The house is 2 floors...
  6. R

    replacement for a Honeywell CM927

    Hi, Does anyone know what product is a good replacement for a Honeywell CM927 wireless thermostat controller and BDR91 Relay Box that controls my electric underfloor heating? I assume it needs to be another Honeywell product and the T4 wireless thermostat but I haven’t found any guidance on...
  7. R

    Help with replacement Glow Worm boiler options please

    I am looking for some basic advice please My house is on two floors, approx 240m2 and a spacious loft with good headroom and access. Glow Worm 30HXi boiler burning LPG housed in a ground floor attached storage room running 16 radiators including 6 doubles and a standard low output shower on the...
  8. Hashtag246

    Thermostatic valve replacement problems

    Got a porcelanosa shower mixer and i need to change the thermostatic valve. It shows that a special tool might be required to remove it. Can u advise? Thanks
  9. T

    Central heating room thermostat replacement

    Hi all, I have a simple mechanical Honeywell wall thermostat (i think you call it a 2 wire). I want to replace it as it is a bit old and unsightly and seems to have a lot of "play" between on and off. I could obviously easily replace it with the same thermostat or a very similar one, however i...
  10. G

    Replacement Wireless programmer Recommendations

    I have an LG air source heat pump which is controlled by an Optimum Duostat controller This has developed a mind of its own where it ignores the programming So time to swap it out Looking for recommendation for a unit thats easy enough to programme without having 5 time zones Basic time on / off...
  11. Lofty24

    Old Bottle type tap replacement?

    Hi all, Is there a modern replacement for an old bottle type tap with a shower attachment or do they still only do individual taps?
  12. J

    Honeywell CM61 'Smart' Replacement

    Honeywell CM61 'Smart' Replacement - Hi am looking to replace my old CM61 with a smart version, any advice?
  13. DJseals

    Immersion heater replacement

    I want to replace my old immersion heater, it currently has a dual immersion with bath/sink switch, we only ever need the whole tank heated so can i replace with a single immersion? or if i am doing it a a DIYer is like for like easier.
  14. G

    Rusty flue replacement?

    Hi, I have just noticed a damp patch around where my boiler flue exits through to outside wall along with a rusty colour around the collar of the flue bend. I’ve checked the external wall & there’s no water coming in from outside but the flue terminal also has a rusty colour. My regular boiler...
  15. 1rtomlinson

    Replacement cartridge for Milan Modern Thermostatic Shower

    Hi I'm looking for a replacement thermostatic cartridge for this shower which was purchase in 2018 from Victorian Plumbing. The stock code was SK001. I saw another thread about this but I don't think there was ever a definitive answer. If not a replacement cartridge then if anyone has...
  16. king of pipes

    Boiler and cylinder replacement

    Had a look at this job it needs upgrading boiler and cylinder the house is quite big 17 rads, big rooms open vented at present , some pipework under concrete floors client wants unvented and little as possible on show conserned about pipes under the floor so looking for ideas chaps I've a few...
  17. T

    Brittony 2T replacement

    Replacing elderly Brittony 11T multipoints,I have three bathrooms ,two kitchens (heating by baxi wallheaters,preferable to the cost of central heating options). I have three options replace with the main multipoints ,refurbish the two ageing Brittony or replace withtwo condensing multipoints. A...
  18. B

    Atag One replacement

    Hi, I have an Atag iC Economiser 27 boiler from 2017, not the more recent "plus" model. It came with an Atag One controller which is hooked in with a 2 wire OpenTherm bus connection. The controller is about to pack in and I'm looking at Tado instead. The controller battery is on its last legs...
  19. J

    Shower replacement advice needed

    Recently moved into a house and have been told that a shower needs replacing as it has water coming out of the fittings when on and is increasingly hard to turn off. When looking for new showers we ideally want one that will fit into the current holes, and have noticed that some shower valves...
  20. S

    Radiator replacement - measurement clarification.

    I have removed a radiator and wish to replace using existing pipework and valves. The old radiator itself was 1290mm in width with a total width tail to tail of 1330mm. The pipe to pipe measurement is 1350mm. The height of the old radiator was 430mm however I could go to 500mm with the new...