room | Page 9

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

room

  1. O

    Room stat nest

    Hello all, just a qick one, are you considering Nest as a good room stat? Is the price worth buying it ? Just seen it few months ago and wanted to know what's your opinion about this particular product. if not what's the alternative, what sort of stats you recommend or love to install based...
  2. A

    Single Room Underfloor Heating

    Hi All, I have installed UFH in my kitchen extension. Problem is to get it started. I can feel that hot water is going trough pump, but no heat water is coming back. So I thought either it's connected wrong or I have a air in the system. Please see file attached with pipework explained. So this...
  3. B

    2x open flued fires in the same room

    Alright guys? Just a quick one. If there is 2 open flued fires in the same room, totalling 13kw combined, but the room used to be 2 rooms eith the dividing wall now removed, does it now need a vent? Or is adventitious air still applicable as it used to be 2 rooms?
  4. jaydebruyne

    Wireless Room Stats

    Went to a job today reporting of no heating. Heating only boiler with a cylinder for dhw - s plan. After creating demand on the water, confirmed the pump and boiler was fine. After testing I found the wireless receiver to be at fault - I bridged the common to the call and ran the heating, all...
  5. M

    Neutral on room stats

    Some have it, some don't, but can anyone please explain why? What does it do? As the stat is a simple on/off switch. I fit Honeywell two-wire ones normally so I've never really had to think about it except when replacing stats like-for-like but would like to understand the principle.. Cheers!
  6. jaydebruyne

    GAS Question - Open Flue vs Room Sealed

    Just to reiterate, Croppy said it was cool to ask gas questions in here as I'm doing my gas at the mo. Well, I've passed all my exams and practicals, I just need to do my portfolio. Anyway.. How do you tell if, say a boiler for example, is room sealed or open flued (if the open flued boiler...
  7. N

    Noise travelling through ventilation pipes from one room to another

    I have a problem with noise travelling through the extraction system in a house, going from one room and travelling along the pipework into another room. Not ideal as you can hear people on the other room including in the bathroom too! Is there any way I can insulate against this at all?
  8. S

    Two rads + room thermostat - omit TRVs on one, or both?

    Hi Guys - just a quickie! I'm aware that a TRV shouldn't be fitted to a rad in a thermostat-controlled room, but does that apply to all rads, when more than one is fitted in the room - regardless of how they may be proportioned? Cheers
  9. D

    Timer and Room Thermostat for Ideal Logic Plus 35

    Ideal Logic Plus 35 or Ideal Independent Plus 35? - both fit into the existing boiler space so which one would you recommend?. Am I right in saying that internally thiese are identical and the only difference is in the outer casings? Is the price difference worth it and if so -why? 2. Best...
  10. R

    Trvs on rads in the same room

    Can someone confirm please I'm correct in thinking if you have 2no rads in the same room you only put a trv on one of the rads? If so what's the science behind this and is it also a building reg recommendation ?
  11. P

    Garden room drainage...

    Hi folks, I'm trying to work out drainage for garden room with 1 x toilet, 1 x basin, 1 x shower. Because the drain has to run several metres to get to the building, there is very little height to play with to connect into it. I have attached a sketch of what I'm thinking of doing...
  12. MarkAqua

    Steam Boiler plant room

    Far from finished - in progress and plenty to do
  13. T

    Wet Room Specialists

    Hi Chaps Just wanting to know if there is anyone who specialises in professional wet rooms on here? im looking at breaking into this market after getting more experience but i was wondering if anyone would be kind enough to let me tag along on one of your jobs for a few days I dont need...
  14. S

    Room sealed flue position to window

    Got a flue next to Double window one side opens which is furthest away from flue. The fixed window is closest to the flue. Would you measure from edge of closest window to edge of the flue which is around 275mm or from openable window to edge of flue which is 875mm??
  15. K

    Smelly cloak bog room

    I have to revisit a property. Issue is downstairs w/c in a solid floor (asphalt) property. Drain goez through floor. No split in pipe. Pan connector changed, basin trap changed for anti vac type. Nothing else in room. Room stinks of open drains. Smell comes in summer and goes in winter. No...
  16. T

    Hive room stat or equivalent

    Evening all i need to change my room stat as ours is on the blink and being my own gaff I fancy a hive stat and receiver that can be controlled by our iphones or a equivalent. The only place I seen hive is through British gas, being a plumber I kindly won't pay them toe rags way over the odds to...
  17. A

    Flueing and Ventilation Situation Classification - Commercial Boiler Room

    Got a couple of situations just wondering if any commercial guys could give me some advice on classifications. 1. Nine Hamworthy UR 430 open flued boilers connected to one flue. Think the maximum should be six. Everything ok, burner pressure, gas rate, flue flow, no spillage with all...
  18. W

    Ventilation for multiple appliances in the same room?

    Hi there, Im about to take my ACS and need something clearing up. I was taught that if you have 2 or more appliances of the same category in a room (e.g. Open flued boiler & a radiant gas fire) then adventitious air is not taken into account. However, reading other books and online literature...
  19. T

    Room stat

    Hi ive quite a bit of experience in servicing and fixing oil boilers as i have in the past done my oftec 101.I also have a oil pressure gague and a kane 250. My problem however is with the heating controls.I have not been out to the house but the boiler was firing but no heat in rads.He took...
  20. H

    Room for one more

    Hello, i came across this forum and thought i should be a member, so here i am. I have been involved with plumbing and heating for 30 years or so now, but still learning !!