soil pipe
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

soil pipe

  1. K

    Connecting bath drainage to soil pipe

    Hi all, I need to connect my bath drainage to my new soil pipe. I have only one spare entry to boss into the pipe at the very bottom (see photo). As the inital entry out the wall will be on a gradient I was wondering if there was a combination of elbows I can utilise to get a 90 degree vertical...
  2. P

    Access Point for existing Soil Pipe

    Hi, I'm wondering what is the best way to add an access point to both the existing soil pipe and waste pipe from my ensuite bathroom in the picture below? Shower is draining slowly for the last month or two and now the toilet is clogging so better to tackle it now I suppose. For the waste...
  3. CitizenErased

    Bossing shower waste into soil pipe vs. separate shower waste

    Hi, We're in the process of upgrading 2 bathrooms in our house: the ensuite and the family bathroom. These adjoin one another. The ensuite is largely done so has all piping in situ. The ensuite required that we feed its soil pipe through the wall into the family bathroom, where it angles...
  4. R

    Seal soil pipe gap/ downstairs toilet

    Hi all Just wanted to check if I can seal the gap between pipes with foam or silicone or by any other method. Thanks 😊
  5. S

    Fitting new soil pipe to access chamber

    Hi all. Not sure if it's a plumbers job or another trade but thought I'd ask. I am installing a new toilet downstairs next to an outside wall. There is a 3 way inspection/access chamber about 1.5 metres outside this point which I plan on going into. It has one inlet in use from the upstairs WC...
  6. L

    Soil pipe going outside.

    Hi, I've not posted for a while, not a plumber, but a keen DIYer who likes to try and do things without bodging if I can. Basically I'm wanting to create a cloakroom toilet in our utility room, theres already hot and cold feed so thats one job made slightly easier, thankfully. The problem I'm...
  7. M

    Clay to 110mm plastic soil pipe fitting

    Has anyone seen this fitting before clay to 110mm plastic
  8. C

    connecting to soil pipe

    Hi , i'm new to this forum & would like some advice , i have an upstairs bathroom & was wondering if i could put a cloackroom loo downstairs , my worry is how do i connect to the existing soil pipe , or is it possible to dig under where the new loo will be in case the soil pipe runs along the...
  9. M

    Soil pipe/fittings 110mm sizes!

    It's not every day I deal with 110mm soil pipes, therefore I do not have a selection of different fittings at hand to try what combination fits my needs. I have therefore been trying to locate on- line the actual sizes eg length of push-fit tee, spread of branch, before I can purchase the best...
  10. B

    Blocked Toilet Soil Pipe

    My soil pipe on the downstairs toilet seems to be partially blocked. Now I know it can be rodded but I was thinking of another way. With the toilet removed and exposing the soil pipe I was thinking of making a reducer to fit over the 4 inch pipe down to a garden hose pipe size and then turn the...
  11. D

    Wall mounted toilet problem with offset soil pipe.

    Hi guys, I've had a search and couldn't find anything related. Installing a wall mounted toilet, unfortunately didn't know this when I put the soil pipe in position. The supplied fitting is now approximately 130mm offset from the vertical connection. Any ideas? (amateur obviously!) Wondered...
  12. A

    Soil pipe connection?

    Fitting a new toilet onto this old cast soil pipe that only fits in about 2inches. It's coming through the wall at an angle and can't be changed because of an extension below. The new pan connector keeps dripping on a full flush any ideas on a solution other than silocone which the old one had...
  13. Sannie

    Soil Pipe Connection

    What size coupler do I need to connect soil pipe to main drain - please see photos
  14. S

    Old Hunter soil pipe socket O-ring woes :(

    Hi all, Have got an old 60/70s PVC soil stack, the Toilet is going into a Hunter branded socket which has an old O-ring design (quite flat with 3 or 4 ribs on it). It's painted in a fetching pink/purple colour in the photo. Tried to revive it with some grease before inserting a short length of...
  15. S

    Advice on old Osma soil pipe boss

    Trying to connect up new 40mm waste into the old soil stack (which would be an absolute pain to remove), it's all Osma pipe, from the 70s. Pulled out the old waste from the boss and discovered the seal is pretty knackered, hardened and cracked everywhere (red coloured seal in the photo)...
  16. AntEpping

    Blocked soil pipe after installing replacement toilet

    Hi - I'm not an expert but wondered if anyone might be able to assist. I've replaced an old toilet with a new one. I've used the same water inlet pipe, and have just replaced the right angled soil pipe connecter (110 at toilet end to a 97-107 connector end to existing soil pipe). It's secured...
  17. D

    Soil pipe base - solution acceptable?

    Had a collapsed/cracked collar on the 90deg angled piece that my soil pipe sits in which is leaking water so has needed replacing. Access has been through the outside wall to inside as the soil pipe is internal and boxed in. Now I was expecting the plumber to fit a ‘rest bend’ but a 90 degree...
  18. B

    Soil pipe cross flow between sink and shower

    Attached is a ground floor picture of the soil pipe in our home. There was originally a toilet which has now been permanently capped off and you can also see a sink waste pipe attached. My plan is to drill out one of the 50mm sockets directly opposite the current sink waste for a new 40mm...
  19. W

    require suitable fitting lead to plastic soil pipe

    need to go from 3.5" lead soil pipe to 110mm plastic soil pipe
  20. L

    Neighbour threatening to sue if I don’t remove my soil pipe wall??

    Hi, just wondered if anyone has been through the same situation? My neighbour wants to turn her garden into a car park for lodgers and has bought an expensive sports car. We can currently fit a normal size car down the driveway but the sports car is bigger than a normal size car. She has now...
Back
Top