soil pipe | Page 3
  • Welcome to PlumbersTalk.net

    Welcome to Plumbers' Talk | The new domain for UKPF / Plumbers Forums. Login with your existing details they should all work fine. Please checkout the PT Updates Forum

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

American Visitor?

Hey friend, we're detecting that you're an American visitor and want to thank you for coming to PlumbersTalk.net - Here is a link to the American Plumbing Forum. Though if you post in any other forum from your computer / phone it'll be marked with a little american flag so that other users can help from your neck of the woods. We hope this helps. And thanks once again.

soil pipe

  1. I

    Can i connect waste pipes into soil pipe tee on a horizontal run? I

    Obviously I know the boss parts on a soil pipe tee are there to be cut out to connect waste pipes and I have done this when it is not a horizontal run but i was wondering if i can connect the soil tee horizontally and still connect waste from it? I have attached the part and rotated the inage on...
  2. J

    Static caravan soil pipe venting

    The soil pipe from the static caravan goes straight down through the floor. What I plan is to run a Tee from this to connect to a vent/air intake on the other side of the caravan. Just wondering does the fact that the vent pipe joins the soil pipe after the tiolet affect how it would work...
  3. A

    Soil pipe leaking, and diy inspection?

    I’ve had a rodent problem in the loft (I know they are in the drain because I saw rats in inspection chamber). The soil stack appears intact in the vertical loft section and vented at roof. I’m pushing the insurance to get a drain survey (water company did cctv the drain and said no defects)...
  4. F

    Is it possible/within regs to move a Toilet soil pipe?

    Hi all We are currently renovating our house and would like to know if we can move the toilet soil pipe a few feet from its current position? Basically, we had an airing cupboard on the landing. That airing cupboard back wall backed on to the toilet. so, for example...If you were in the...
  5. J

    slope question about relocating WC soil pipe

    Hi, I'm doing a bathroom refurb and wanting to move both the WC and wash basin over to the right. In the picture attached, green is how I think I should position the new WC and orange is how I think I should position the new wash basin. I know that the waste pips should have a slope between...
  6. J

    will the soil pipe connection rotate?

    I am moving the position of a WC which connects to the roof vent pipe and discharge pipe. To do so I would like to rotate the soil pipe about 40 degree anti clockwise. My question is: will the multi purpose boss connector the soil connects to rotate if I re position it? Thank you once again.
  7. P

    Soil Pipe Angle Options - Advice & Help required

    Hi All, Having the layout on the ground floor reworked, the plans to do so included moving the internal vertical soil pipe on the ground floor too. This pipe picks up the bathroom and en-suite on the 1st floor, and bathroom on the top attic floor too. So quite a bit goes through it, though on...
  8. 3

    Soil pipe in chimney breast

    We live in a Victorian apartment on 1st floor. Our new upstairs neighbours want to relocate their toilet from the outside wall to an inside wall and run the soil pipe through an unused chimney. Is that wise?
  9. S

    Advice on what to do with soil pipe for sink waste and toilet

    After some advice. I have had my floor done downstairs but the current waste inlet is too low for the basin waste and will need boxing in and also the pan waste in the floor isn’t in the center of the room. I have a back to wall toilet and will be installing a floating sink. I plan on chasing...
  10. T

    Soil pipe boss removal.. Help

    OK so I've started and my original plan is looking good. Is the bottom of that boss push fit? Will brute force get it off? If not how am I going to cut it out .. is there a fabulous tool that will get in there between two joists and a wall. 🤯 Really don't want to be damaging kitchen underneath...
  11. T

    Rotatimg soil pipe fitting

    Hi. Could anyone advise if this is a push fit fitting that I can rotate? If I had to cut out the section I'd have to do from below in the kitchen which might be problematic. I've applied some wd40 in prep for when I disconnect toilet but not sure if it will move. Thanks
  12. L

    Soil pipe to sink fitting?

    Morning, sorry for such a basic question but I I don't know what fitting to use! I have a fitted toilet which is being removed and a small kitchen sink being put in place. The soil pipe is coming out of the wall horizontally. I'm used to a boss fitting but I need to blank this? I saw a fitting...
  13. S

    Does pan need to fully-insert into soil pipe?

    It’s time to buy a new toilet and I need to ensure that the one i buy will meet up correctly with the soil pipe outlet (sunk in floor), such that the cistern sits against the wall. My question is, is it necessary for a pan spigot to fully insert into the soil pipe connector (McAlpine WC-CON8)...
  14. R

    Soil pipe replacement cost and advice

    Hi, Need some advice about a soil pipe in 1966ish built ex-mod property. We have suspected but not be able to prove that since some heavy vibration from Pilling for a school across the road was done that our soil pipe has cracked, we are 99% sure it's cast iron from what neighbours have said...
  15. D

    tricky soil pipe connection

    Hi I need to connect a kitchen sink to a soil stack but the soil stack has an inspection hatch and what looks like a reducer into a clay pipe into the floor making it very difficult to fit a boss. This should be pretty straightforward with a boss, but the level where the boss needs to fit is...
  16. Stants

    What is the fall for connecting a 40 and 50 mm Drain into a soil pipe

    Hi could anybody tell me or post a link for the correct fall / gradient for a 40 mm and 50 mm drain pipe ( Shower ) connecting into a new soil stack im guessing it would be one in something or degrees Thanks
  17. H

    Bathroom Waste Layout - Horizontal Soil Pipe

    Hello, I would very much appreciate some help/feedback on what I am proposing for my very small ensuite bathroom. While refurbishing it I’m proposing to add a shower. It’s just 1.2m x 1.6m. I have seen similar posts to this on the forum but not quite my situation. I am proposing to run one...
  18. Lumen

    No flexi, soil pipe into the stack possible?

    Hi chaps, I’m installing wall hung toilet with a frame. I’m looking to run waste pipe without a flexi, but can’t figure out what’s on the market that will do that. The waste on the frame is 90mm and has grooves for attaching into the frame and my soil stack is 110mm. I’m out by about 50mm...
  19. M

    Slightly moving waste pipe connection into soil pipe

    Parents have had a steel beam put into their hallway ceiling to adequately support landing and stairs. This means that the waste from a sink and shower will need to be reinstated slightly lower into the soil pipe, as the pipes will now run under rather than through the beams (the joists will be...
  20. F

    Need advice on joining toilet to a low soil pipe

    Hi everyone, I'm renovation my own house, and I'm just moving on to the bathroom. I've realised that the soil pipe is too low, the bottom of it being only a couple of cm off the floor, whereas the bottom of the toilet pan waste is around 14cm from the floor. I've tried using a 60mm offset pan...
Back
Top