soil | Page 3

Welcome to the forum. Although you can post in any forum, the USA forum is here in case of local regs or laws

soil

  1. C

    Hard to access soil pipe with AAV

    Hi An idiot Bathroom fitter has cut down a soil pipe and fitted an AAV valve, then placed a built in bathroom cabinet with the soil pipe in the corner unit making the only easy way to access anywhere near the soil pipe by reaching up from where the kicker board goes. You can see from the photo...
  2. H

    Geberit cistern waste into 110mm soil pipe

    Hi I’m trying to find something that will connect a geberit 90mm toilet waste pipe into a standard 110mm soil stack. The geberit cistern came with an adaptor that increased the outside diameter of the pipe to 110mm. However this is the same diameter as the soil stack pipe. Is anyone aware of...
  3. T

    Can I put wash hand basin and shower into soil pipe

    Moved to a new house and changing bathroom layout would it be ok to take shower and wash hand basin into soil pipe toilet moving to middle window sink to the right of middle window shower to the first window
  4. B

    Advice on soil pipe remaining in wall (behind toilet)

    Hello all, I'm trying to install a new toilet. The old cast soil pipe has been cut 'flush' to the inside and outside wall. On the inside, I will just use a pan connector. However, what do I do on the outside? Pictures of outside: You can see that the remnant of the pipe in the wall is not all...
  5. G

    Boss connected to soil pipe at 45 degrees

    Hi I'm in process of completing a loft conversion and need some advice on the location of a boss adapter for the shower waste. Can a boss adapter be fixed to a 4" soil pipe at 45 degrees as shown in the pictures? My main concern is that the entry to the soil pipe is on the side and with the...
  6. C

    Soil Vent Connection

    I have to connect the UPVC pipe to the ground. There's a connection of sorts there already. The rubber gasket there has perished but I don't seem to easily find a replacement. Even if I did, the old UPVC pipe I have doesn't fit tightly in there and presumably never did. My question is, does...
  7. bfalp1

    Is a soil vent mandatory?

    My builder has removed the soil vent pipe stating that an AAV would suffice. As I have had some troubles with them I have started to question what they say so I have done a bit of digging. From the internet I don't seem to find a clear answer about this. Could you please clarify this for me? Do...
  8. D

    Options for Soil Pipe/Toilet fitting that conceals the pipe?

    Options needed for Soil Pipe/Toilet fitting. Hi Everyone. - I'm planning a bathroom remodel, and my wife would like a solution that covers the soil pipe up if possible. However, the toilet pipe sticks out from the wall 23cm, and raises from the floor to the mid point of the pipe 21cm. The...
  9. J

    Soil stack reduction

    Can I go from a four inch drain pipe then reduce the soil stack to 3 inches(just under the subfloor below the bathroom floor) then go back to four inch in the attic - above the bathroom? I need 1 inch of room for a 30 by 60 tub - the soil stack is pvc and I need to reduce it to 3 inches in the...
  10. A

    50mm waste run to soil stack

    Hi, When running 50mm waste to the stack, how do I get it so the 50mm does not have to be so far from the wall? As the offset at the stack dictated by the boss on the soil pipe. Hopefully this makes sense! Please see my picture which hopefully helps. I bought a 135 deg bend thinking I could...
  11. Scott_D

    soil pipe deburr tool?

    Anyone use a drill attachment for deburring soil pipe or just whip a grinder around?
  12. X

    soil pipe connection

    Hi all, is there a way to connect a new toilet into an existing horizontal run? The problem is, due to the levels it can only connect horizontally and not from the top of the pipe. Is it ok to use a standard branch connector in this way?
  13. ShaunCorbs

    Cast effect soil

    Anyone use silicon on strap on bosses I’ve got a cast effect stack to do and they a bit bumpy for my liking with glue
  14. J

    Can I Redirect soil pipe?

    We are having a few rooms knocked together down stairs and need to put a window in where the soil pipe is currently. Please can you advise what the regulations are for redirecting this? Can it go round the window and back into the drain below or do I need a whole new drain? I have attached some...
  15. J

    Soil pipe connections through wall underground

    Planning drainage for a new bathroom. Assuming that all the falls/gradients are correct is there anything wrong with this plan? Soil pipe from toilet goes through wall below the floor level so that I can connect a shower waste (wetroom so flush with floor). On the other side of the exterior wall...
  16. W

    Fitting an AAV to this bit of external soil

    Hi all, Custard has this open topped bit of soil which obviously stinks. She has bought two, for some reason, AAV's and tried sticking them in the end but still stinks. I've zero experience with soil and vent but I'm guessing the soil needs the socket cut off and these get solvent welded inside...
  17. A

    Connecting a new toilet into an existing soil stack

    Hi. I want to connect a new toilet waste into an existing 110mm soil pipe. The soil pipe runs from the second floor bathroom, down through the room where I need a new toilet and then down through the ground floor where there is another toilet attached. The soil pipe will not move up or down so...
  18. A

    Poor fall on soil pipe and toilet blocking. Advice for fixes please?

    Hi all, looking for some soil pipe/stack help please. I bought my first house end December and unfortunately had a toilet pipe blockage within a month. Place is old but was renovated in 2014 so thought it would be in decent nick! Plumber came out to rod it end January from the access hatch...
  19. G

    Advice please on a leak that appears to come from the SOIL pipe

    Hy all, So i noticed the corner in the living room was getting damp. investigation showed that the corner skirting board that goes around the boxing in of the SOIL pipe was rotten with mould and the carpet was saturated. Obviously been going on for a long time. I dried the area out. I then...
  20. dave100

    Can I use 90 degree bends in dry soil vent?

    TL/DR: Can I have a bend of 90 degrees in the dry section of a 4-inch soil vent? Hi. I am renovating a small bathroom. There is an awkward part of the wall where the builders boxed off a large section just to conceal the 4-inch soil vent. I realise, of course, that the soil vent is essential to...