    Thermal imaging cameras

    I may have to look for a leak on a heating system losing pressure every day. No sign of a visible leak anywhere, including prv and condense in case heat exchanger is knackered. All ground floor heating pipework is in concrete flooring, has anyone hired a thermal imaging camera and had any...
  2. D

    Elson Coral E Thermal Store Descaling Required

    Hi Can anyone give me some advice please. I think have a scale issue with my electric boiler (8 years old). The symptoms are the water in the shower/taps runs hot initially then runs luke warm after a short while. If you switch off the shower/taps briefly the water then runs hot again when...
  3. A

    thermal stores

    what is it with new builds and thermal stores my company recently got a contract for a hotel/hostel which has thermal stores in all the 2 bed appartments according to the contractor they were the most suitable system because combis cant service more than one hot tap at a time. Now the manager...
  4. M

    Why don't Gas boilers have a thermal heat store like oil boilers

    After living in a property with an oil boiler for three years with a Worcester heat slave Oil combi boiler which has a heat store in it i was thinking why don't all combi boilers have one such as gas boilers? it seems to make combi boilers so much more convenient
  5. D

    thermal store incorrectly installed

    Dear All, We have a flat that has electric only. When we renovated it, we took out the unvented cylinder and installed a thermal store which also 'powers' a wet central heating system. The plumber who installed it had never worked with a thermal store and was convinced it wasn't going to...
  6. V

    Leaking solar thermal panel repair??

    Hi I have a double Solux roof integrated solar thermal flat panel which has developed a water leak since the cold weather earlier this year. I can't see where the water is leaking from because it is running between the roof felt and slates then into the gutter/downspout. Does any one know if it...
  7. A

    Blending valve for solar thermal/combi

    Anyone got a link for a decent blending valve for a combi using solar preheat? Intasol's is £295 plus VAT!!
  8. Z

    Solar Heat Bank Thermal Store Pre-Heat For Combi Using Plate Heat Exchanger

    Hi there, I've got a Baxi Duotec 40, had it for about 2 years now and seems to do exactly what i intended it to, I had it fitted just after we bought our first home 2 years ago, previous system was a back boiler with Hot Water Cylinder, I completely replumbed the house when we moved in and had...
  9. G

    solar thermal just for hot water.

    hi i am a spark, who has fitted solar pv on south facing roof.i am now looking at getting solar thermal, to supply my hot water ( just for upstairs, one shower and 2 sinks)have got combi boiler worcester, 30cdi. but dont want to get involved with that. have 2x2mts, on south facing roof, but also...
  10. J

    solar thermal hot water course

    Hello to all I am going to do this course soon and I was just wondering whats the exam like is it open book how many questions that sort of thing what is the best wat to revise for this Thanks
  11. gassafe

    Thermal store confusion!

    I went to quote a nice straight forward boiler! Just a potty profile to Ri boiler... all going well until I saw a big thermal store in the airing! I hate the things, they scare me! It's because I am not familiar with them & there operation! This one had two pumps in the airing, I'm guessing...
  12. P

    Ariston 210 STI Indirect Cylinder thermal cut off

    Hi guys I'm havin a problem with this cylinder, not dealt with these for a long time, what's the best way to check the thermal cut off device in these?
  13. H

    Thermal imaging

    Hi guys any one got any recommendations for thermal imaging camera?
  14. Whn1

    Thermal camera.

    Has anybody ever used one for plumbing purposes and does it work.. Im talking about tracing leaks in screed, looking at UHF circulation.? Just a thought.
  15. M

    Broken thermal store --> heatbank?

    I have a 210L Albion thermal store, electric only, used for hot water. The coils inside have obviously gone and are leaking into the store as it is overflowing (ruled out the ball valve and filler mechanism). Question is: can I convert this to a heatbank with a plate heat exchanger? It's either...
  16. C

    Ecocat Thermal Store - Heat buffer depleting hot water cylinder

    Will try explain this problem best I can. I have a Ecocat thermal store (Chelmer heating) for central heating and DHW. My understanding is the the cylinder has a hot water section at the top and a heat buffer below (for central / underfloor heating). The Chelmer diagrams show both of the tanks...
  17. C

    Unvented cylinder vs thermal store (1 floor flat, no gas/renewables, soft water)

    Hi, I'm in a one-floor flat, currently with a cold water tank about 4 foot above floor level and an electric immersion tank underneath it at floor level (no gas, Economy 10 electricity). This obviously is a disaster for anything except a bath: there's a shower hose attached to the bath taps...
  18. G

    Looking for air source heat pump and solar thermal installer in Edinburgh

    We are a renewables company based in Edinburgh and we are looking for a subcontractor to work with us installing heat pumps, solar thermal and biomass (you will need to be qualified but not MCS). If you are interested in working with us please contact me, email in profile. Tom
  19. S

    Heat bank (thermal store) linked to wood burning boiler. Engineer needed.

    Hello all. I am renovating my house very shortly and would like to fit a large Wood burner with a back boiler and link this to a Heat bank (thermal store). I have a very good idea of what I want, but would like to ensure it all works efficiently and reliably by getting a heating engineer...
  20. J

    Replacing Thermal Store Question

    Hi All, My 16 year old Albion Mainsflow Integrated Combi Thermal Store (Direct) MF30/180 has split and needs replacing. I have had a couple of plumbers look at it and both have quoted me around the £2000 mark. I never expected it to cost anywhere near that but find that the cylinder alone is...