  1. E

    How to recharge an expansion vessel?

    Hi, When my boiler (regular vented I believe) is on there's a constant trickle of water flowing out a pipe to outside (coming off the red vessel in the image below). It's happened in the past and IIRC the expansion vessel needs recharging. I'm pretty sure it's the case again as when I take the...
  2. S

    Correct Expansion Vessel Pressure

    Evening all, So I've been losing pressure from my boiler on a daily basis and having to top it up. The pressure gauge is up at around 3.5 bar when the boiler is on so I assumed the expansion vessel has either failed or is low on pressure. I had a look on both the Cimms website (the EV is a Cimm...
  3. danieljamesphoto

    Changing kitchen taps with an expansion vessel

    Hi, i'm a complete newcomer to plumbing so be gentle, basically i'd like to change the kitchen taps (just a simple monobloc mixer tap) and have looked on YouTube and think I have everything ready. I've had a look at the system and it seems to be setup to include an expansion vessel (image...
  4. P

    Combi KW Rating (High or low?) - Fit De-aerator and Extra Expansion Vessel?

    Hi All, I am looking to replace an Ideal Classic FF350 in a 4 bed detached house, 1 main bathroom with a bath and electric shower, also en-suite with a thermostatic shower that is currently pumped (knackered) from a DHW cylinder (essex flange weeping). F&E and CWS tanks in the loft, gravity fed...
  5. Scott_D

    Shock arrestor / mini expansion vessel

    Do you fit them when fitting a combi? What type? Mechanical shock arrestor or mini expansion vessel with shreader valve? Do you service them annually?
  6. C

    Drip from central heating additive vessel. Does it unscrew? I can’t budge it.

    I’ve tried unscrewing this thinking I can use ptfe tape and re-screw it, but it’s not budging. I don’t want to force it if I’m wrong and it doesn’t have a thread. Does anyone know please?
  7. N

    Groaning Expansion Vessel

    The tundish near the expansion vessel started dripping, plumber came and pumped up expansion vessel and dripping stopped, great. However now, every time we flush any of the loos we get a strange heavy vibration noise through the expansion vessel for 1-2 seconds. We also recently discovered it’s...
  8. M

    Expansion vessel insert, should I remove?

    Has anyone installed a Refix potable expansion tank? There's a plastic insert inside the 3/4 threaded connector - should it be left in? I though it maybe to space the diaphragm off the inlet point, but not sure if it's just a protector insert which will stop the tank operating - nothing in...
  9. J

    greenstar 24i expansion vessel hose

    I have removed an old expansion vessel from a Worcester greensatr 24 i. I am now trying to reconnect the hose but I am having great difficulty. Its so tight inside the fitting. Is there an easy way to reconnect it? Thanks
  10. M

    HW expansion vessel pressure and sizing

    Afternoon, I am not a G3 engineer but am using the downtime during COVID to do some extra learning. Is there a calculation to use to correctly size the expansion vessel and have the correct pressure in the vessel on unvented HW systems? Thanks
  11. M

    What pressure to charge HW expansion vessel?

    Afternoon, this is purely a query and learning benefit. I am not a G3 qualified engineer, however am just using the down time during COVID to take on some extra learning. Would anyone know if there is calculation or something to determine what pressure and size the vessel should be on an...
  12. M

    To fill expansion vessel with water?

    Hello! I’m wondering which will cost more - to run our heating system with an inefficient/broken expansion vessel for a minimum of six months from now, or to call out an engineer (£100 excess). Our house is a new build and still under warranty. I noticed the pressure in our unvented system...
  13. J

    Why would cold mains feeding the boiler need an expansion vessel?

    British gas fixed a leak in the boiler and said the due to the recently installed water meter the fluxuation in pressure caused the leak. They advised to get a expansion vessel on the the cold mains entering the boiler. I read on here someone say that Worcester wouldn't warranty boilers being...
  14. Jock Spanners

    Where's the best place to site a heating expansion vessel?

    Evening all, I'm converting a regular boiler to a sealed system and unvented cylinder. The Megaflow is in the bathroom and the boiler downstairs high on a wall. I'm running the cylinder vent to the soil stack. I'm struggling to decide where to put the expansion vessel on the heating. It's an s...
  15. N

    Best solution for a failed expansion vessel?

    I have a Vaillant Turbomax Plus boiler, fitted in 2005. Recently it's locked out several times due to low pressure, which prompted me to check the expansion vessel. When I pressed the Schrader valve I found that water, rather than air, was released. That suggests to me a failure of the...
  16. J

    Repressurise white expansion vessel

    Hi all, I've got my G3 card. First time I've attempted to re-pressurise the white, expansion vessel above an unvented cylinder. I first turned the water off, ran the taps to relieve the pressure. The vessel (it was flat). I managed to pump it up to 1.2bar with no issues. But then it was...
  17. F

    Best CH expansion vessel

    Hello again from enthusiastic amateur. Previous request for help re daughter's pressure reducing Ideal boiler helped me to get it sorted economically. Today my query is re my own system with Worcester Bosch system boiler where I think the built in expansion vessel is inadequate or faulty. I...
  18. M

    External pressure vessel

    Fitted an external expansion vessel to closed system central heating system due to failure of internal boiler vessel. Fitted on return below wall mounted boiler. Vessel pre-charge pressure checked prior to fitting, confirmed at 1.3 bar. System purged of air and pressurised at cold to 1 bar...
  19. quality

    Best powered vessel pump

    As above folks 5 words
  20. A

    Expansion vessel

    If there is an unvented cylinder being installed in the loft, System boiler downstairs, how would you decide what size expansion vessel to put on the heating side and how will you configure the Pipework for heating expansion vessel in the loft. As there will be an expansion vessel in the boiler...