Local branch manager is trying to sell me Vokera C30 combis, says very good boiler but full kit is £400 cheaper than Worcester or Vaillant, they offer 7 year warranty but Iv never fitted or used after sales so no idea, anyone got any answersplease
Hi Guys New to the boiler diagnostics, so go easy
http://www.vokera.co.uk/wp-content/uploads/2014/02/Compact_A_User_and_Install_Manual-v1.pdf
Carried out initial electrical safety test.. Earth resistance, Resistance to earth, Short circuit and polarity all ok.
Put a hot water demand on the...
Been to this it cuts out on hw after 30 sec with 07 code. In htg it runs until rads get hot and 56-62 on display then locks out with 07. Called tech but line was bad they said when it locks out turn a control knob to 9 o clock to Display temp boiler has reached anyone any ideas and which control...
All,
We have a Vokera 20e gas boiler which was working perfectly up to the point where we “upgraded” the 2 old timers (2 zone timer and 1 zone timer) to a new combined 3 zone timer from Climote. climote.ie
Since the install we have been getting intermittent ( i.e. a couple of times a day) red...
My boiler is over pressurising, and venting out of the PRV outside (Continually dropping) I have replaced the PRV and checked the expansion vessel that needed topping up. I did notice that when I had toped up the Expansion vessel that the water gauge when up to the pressure that I had put into...
Hi there I am having a problem with the hot water on the above boiler
At first the hot water was running hot then cold hot then cold due to the boiler cutting off so I replaced the plate heat exchanger and the problem was solved.
But now the water only runs lukewarm when the tap is run...
Before i wave the white flag, do we have experts on the dreaded Vokera Compact 29HE Combi
Customer initially reported no heating or hot water
I went to look at the boiler and it was dead, no pump or fan activity, then it just started working and did so until i left. Customer then reports the...
Gotta go look at a vokera comact 24 this morning its an old stlye on with the twin pass hex. Heating works fine but when hot water it cuts out straight away.
not come across this fault before. So was wondering if you guys had any ideas.
thanks in advance
Hi all,
Have a problem with a Vokera Maxin24e which is not firing when there is a demand for hot water. The piston on the divertor valve is not coming out to make the microswitch. I had parts from an old boiler so I swapped the valve and the domestic distribution manifold out as I had them as...
Can anyone help me with this. Was getting no heating and hot water. Spoke to Vokera and explained symptoms and they said clean Venturi which I did . The beige part at Venturi was broken which don't know if this is cause because boiler fired after a cleaned Venturi for about half an hour then...
Hi. I have a Vokera Compact 29a which was installed new nearly 1 & half years ago. The last few months the pressure has been rising into the red and on occasion water leaking a little from left side when pressure too high. Have been bleeding radiators to reduce pressure and sometimes you hear...
Called to an 18 month old Vision 30C earlier with poor hot water. Hot water luke warm at best showing a max of 35 deg on boiler display. If slow tap to little more than a trickle the temp gets up around 60 deg eventually. No issues with heating.
Boiler fitted to an old back boiler heating system...
Hi im have trouble with the above bolier.
When i run the hot water the bolier heats it for about 20secs then locks out. While its heating i can hear the igniter fire multipul times then the bolier locks out and the water goes cold.
Having had a look inside i can see that theres water...
Broke two rules thus week.
1 don't do any work in the village for mates! Or mates mates!
2 don't do boiler repairs!
Went out to a friends, friends boiler in our village. ( vokera linea 24) prv was passing and loosing pressure in about an hour. So called in yesterday. Changed prv and checked...
Hi guys. Just hoping someone could give me some ideas as to what could be causing problems with ignition on a compact 25 (g c no 47-364-01)
The boiler seems to fail to ignite but is sparking and I can hear the gas ignite before going out and trying to spark again until it goes to lockout...
Can anyone help please ? I have a Vokera 14e boiler it ignites fires up for 10 seconds then red light flashes I have gone through the reset procedure many times I have had the fan, circuit board, thermistor all replaced the water pressure is stable at 1 to 1.5 bar any advise would be gratfull...
Hi All,
i have vokera compact 25 that was not working at all. Had a good look at it and it ran with the cover off but not on. Diagnosed it as a Venturi. Replaced this and thought problem solved. Now the boiler works great on DHW but lights for about 10 seconds, then stops for 3 minutes, then...